Article: 30009349.
Documentation
Prospect Logano S111-2 | 524 KB | |
User's manual | 1.44 MB | |
Installation and maintenance instructions Logano S111-2 boiler | 1.63 MB | |
Certificate of conformity | 592 KB |
Modern concept of boiler
Connecting to the chimney
Application area
Universality of application due to the possibility of burning large pieces of fuel
Price Retail: Add to Cart, Pieces: Delivery:
From ~? ~ Rub.
Article 30009350 Fuel Type Solid installation type Floor thermal power, kW 45.0 Heat exchanger Material Steel Number of contours Single-circuit fuels Brown coal, wood, briquettes, Cox Power modulation, kW 18.0-45.0 Power supply, in non-volatile average efficiency,% 73- 82 Boiler water temperature, ° C 95 Automation included No display No Water connection (straight line), G "1 1/2 Water connection (arr. Line), G" 1 1/2 Diameter of chimney, mm 180 height, mm 1045 width, mm 688 depth, mm 980 Weight without water, kg 320 Country of origin Czech Republic Warranty 1 year
Type of fuel
Types of fuels of heating boilers are divided into gaseous, liquid, solid, or substance, incinerated to heat.
Among the heating boilers in a separate group you can endure the same electric boilers - The most eco-friendly of all types of boilers.
The cheapest, today, the type of fuel in Russia is natural gas. Followed by solid fuel, Electricity and diesel brass.
Boilers designed to work on gas are usually tuned to the main gas - methane, but in the absence of a main gas, they can be converted to work on liquefied gas - A mixture of propane-butane.
Liquid fuel is diesel fuel, fuel oil, synthetic oils. In everyday life used diesel fuel - diesel fuel. Today it is one of the most expensive types of fuel. As a rule, it is resorted to its use in the absence of a main gas and sufficient for heating of electrical power.
Solid fuels include firewood, coal, peat, pressed sawdust (pellets). These fuel types are relatively cheap (depending on the specific conditions of the region).
type of instalation
The type of installation of heating boilers is divided into wall and outdoor.
The installation type is determined constructive device boilers, their power, as well as the type of fuel used.
Recently, gas and electric wall boilers, in which, as a rule, are all necessary elements "Boiler": pump, expansion tank, security group, automation, heat exchanger for DHW, etc.
Thermal power, kW
Nominal thermal power is the power that can be removed from the boiler directly to heat the trimmer, i.e. This power takes into account the loss of heat (efficiency).
Nominal thermal power is measured in kilowatts (kW). The higher the efficiency of the heating boiler, the less the difference between its nominal thermal power and thermal load.
Heat exchanger material
Heat exchangers of heating boilers are manufactured from different materials.
W. outdoor models Heating boilers They are usually made of steel or cast iron. And steel and cast iron have both their advantages and about the shortcomings and speak unequivocally about the benefits of this or that material incorrectly.
Wall-mounted heat exchangers are most often made of copper and stainless steel. And the first and second have high reliability and durability. Sometimes on copper heat exchangers Special coating is applied to the increasing service life.
Number of contours
The number of contours (separately controlled branches) equipped with pumps, mixing devices or non-controlled branches equipped with pumps or without a distribution manifold of the boiler installation. One of the systems is connected to each branch: radiator heating, warm floor, hot water heating, pool heating, etc.
Most models of modern gas wall boilers have two contours.
One for heating, the second for heating hot water. Such devices allow to obtain and heating and hot water using one compact device. If it is necessary to expand the number of contours, for example, for warm floors, mixing groups are installed.
At the classic floor boilers out the contour one. Additional contours are obtained using a distribution manifold and mixing groups of automatic controlled.
Power modulation, kW
Power modulation (kW) - Automatic burner power control to ensure the most economical boiler operation. Power modulation is used in wall and condensation boilers.
The power modulation range shows in what limits of the burner can change its thermal power.
Medium efficiency,%
The average efficiency (%) is the average efficiency of the boiler installation for the year.
Boiler water temperature, ° C
The boiler water temperature (° C) is the temperature to which the coolant warms up in the boiler.
Automation in the kit
Automation included - automatic electronic device for managing boiler equipment operations, built into the design of the heating boiler or supplied with the boiler.
There are many different types Automation. One of important indicators - The number of contours of the heating system which can control the automation.
Display
Display - screen to obtain visual information about the operation of the equipment, the temperature of the coolant and error messages.
Chimney diameter, mm
Ø chimney, mm - minimal diameter of gas pipes and chimney. This size is indicated in the passport of the boiler.
Understatery of the smoke cross section absolutely forbidden!
With household walls gas boilers The fan burner uses coaxial (tube in a pipe) chimneys, allowing you to bring fresh air to the boiler and removing the spent gases from the boiler.
Installation
Installation of boiler room includes:
Installation and fixing the boiler in place;
Connecting a boiler to a central chimney or connecting a set of passage through the wall;
Connecting a boiler to heating pipes;
Installation of protective equipment (security groups, expansion tank)
Installing a coarse filter;
Installation of a drain valve;
Connecting the feed line;
If necessary, installing a boiler pump, a submersing pump, a hydraulic separator, a distribution manifold;
If necessary, partial assembly / disassembling the boiler
Installation and connection of one heating group (each subsequent - 5000 rubles);
Filling the heating system by heat carrier;
Adhesive heating system.
Installation of the water heater includes:
Installation and fastening of the water heater in place;
Direct loading line device from the boiler with its pump;
Connecting a water heater to cold and hot water lines;
Device by the need for a recycling line;
Installing protective equipment (security groups, expansion tank);
Installation of a drain valve;
Installation of shut-off reinforcement and instrumentation;
If necessary, installation of thermal insulation casing;
Filling the water supply system with water;
Filling the heat exchanger line by the coolant;
Pressing the heating and water supply systems.
Stacking
Commissioning works include:
Checking the correct installation of all equipment
Checking system for tightness
Checking grounding
Connecting the boiler to the gas highway (diesel)
Installation and electrical installation of weather-dependent automation (with its presence, an additional 6000 rubles + 1000 rubles for each additional circuit)
Setting up automation
Setting the combustion process
Check and adjust the boiler operation in all modes
In commissioning works also includes detailed instructions of those responsible for operating the boiler installation.
After commissioning, the equipment is placed on the warranty.
Annual service
Service maintenance includes :
Diagnostics of boiler equipment
System feeding, podaching of expansion tanks (if necessary and availability of service cranes)
Cleaning the coolery chamber of the boiler unit
Control and adjustment work on the burner
Control and Adjustment Works on the Automatics System
Cleaning mud filters
Operational service for emergency calls of the Customer (Departure, Diagnostics, Repair)
The cost of annual service includes the cost of the listed works and the cost of spare parts that are supplied free of charge for warranty or for a fee is not included. Annual service is a prerequisite for preserving warranty obligations.
Boilers Buderus Logano. S111 work on any solid fuel. This makes them one of the most functional on the market. Consider the features of these boilers and the feasibility of such an acquisition.
The boilers of this series are made of different sizes and capacities offered, from 12 to 45 kW. Due to the design features, it became possible to combine boilers with heating boilersGas or diesel fuel. In addition, the line of models of Buderus Logano S111 found its application and in pumping systems. Some models already in the factory configuration go with the built-in heat exchanger protection and blocking system in order to avoid overheating of the boiler.
To date, the market shows the following Buderus Logano S111 models:
The numbers after the index "111" denote the maximum power of a solid fuel boiler in kilowatts. All models have a combustion chamber open type, wherein hot water Served in the heating system by one-circuit scheme. The symbol "D" denotes models with an increased furnace, as a source of energy in which wood and lamps are used up to 50 cm long. Wood moisture in this case should not exceed 28%. The efficiency of all models is from 72 to 82% depending on the quality and type of fuel used.
Due to the presence of a roller and surround combustion chamber in the boiler for the heating of the room, it is necessary to bookmark the fuel just twice a day.
All models of the Buderus Logano S111 series are distinguished by high efficiency and good characteristics. Thanks to a wide model range, it became possible to choose the model to your taste:
1. Logano S111 12:
2. Logano S111 16:
3. Logano S111 20:
4. Logano S111 24:
5. Logano S111 25MAX:
6. Logano S111 32:
7. Logano S111 32D:
8. Logano S111 45D:
To ensure constantly high performance, it is necessary to take care of a good thrust in the chimney.
Even a special search for negative reviews about boilers did not give anything. Although it would seem for more than a three hundred years of the existence of the brand were to manifest themselves and flawed. However, no matter how difficult it was to believe in it - there is no negative information.
For all modern models Boilers operates the factory warranty in 2 years at the time of launch. With proper use maintenance Required once a year, and during the warranty, the installer is carried out.
Of course, quality costs money. On the other hand, the miser pays twice and easier once to buy reliable and durable equipment than to change components every year.
Technique requires appropriate maintenance, so when purchasing a boiler, it is necessary to carefully examine the instruction manual. In terms of heating, this boiler can stall except that only the choke cartridges, which at the price value on average five times less heated house no worse, and the time spent on heating is less. Hence the conclusion: it is first to consult with several specialists to determine what is still the type of the boiler for heating to put in your home.
Buderus Logano S111-2 Heating Copper 16
Solid fuel boiler Logano S111-2 It is used for heat supply apartments, cottages, administrative or industrial buildings As the main or autonomous heat source. You can use wood, briquettes, brown coal or coke as fuel. Suitable For use in systems with natural and forced circulation of the coolant, with open and closed expansion tanks. The lineup Presents the nominal capacity of 12-45 kW.
Small boiler dimensions allow it to be easily installed in a new or existing heating system. It is easily combined with boilers working on diesel fuel or gas.
Despite the small area used for installation, the upper boot chamber (providing the nominal boiler performance) is designed to supply lanes up to 53cm long. Which are loaded through the upper part of the boiler. The large volume of the combustion chamber and the ashtar provides a long combustion process. The combustion chamber with top loading and shaking grate grille provide convenience during operation and maintenance.
The boiler is equipped with an automatic thermostat for controlling the combustion intensity and temperature sensor to control the temperature of the coolant. Possible equipment of a boiler with a heat exchanger for additional protection from overheating.
Features and advantages of the boiler Logano S111-2:
Design and conditional designations in the scheme, see Fig. 1.2: