House, design, repair, decor. Yard and garden. Do it yourself

House, design, repair, decor. Yard and garden. Do it yourself

» Budrus Logano with 111 installation. Service of the boiler

Budrus Logano with 111 installation. Service of the boiler

Article: 30009349.

Documentation

Prospect Logano S111-2 524 KB
User's manual 1.44 MB
Installation and maintenance instructions Logano S111-2 boiler 1.63 MB
Certificate of conformity 592 KB

Modern concept of boiler

  • Steel heating boiler operating on solid fuel is designed for heat supply apartments, cottages and administrative buildings.
  • It is used as a separate boiler or in combination with a heating boiler operating on gas or diesel fuel.
  • Suitable for use in pumping or gravitational systems.
  • Narrow dimensions allow you to use a boiler in small rooms.
  • Built-in heat exchanger as an additional option.
Power features
  • 7 standard sizes in the power range of 12 - 45 kW.
  • The prolonged combustion process is provided by large volumes of the loading chamber and the ash bar.
  • Wide range of applications thanks diverse choice Fuel. It is possible to use other types of solid fuels: coal and coke.
  • Boilers Logano S111-2 32D and 45D are designed specifically for use as a fuel of wood; The length of the PLAN can reach up to 33 and 53 cm in length, respectively.
Quick installation and easy maintenance
  • Single installation in already existing systems.
  • Easy access and simplicity cleaning the flue space.
General provisions
  • The body of the Logano S111-2 boiler is made of high-quality stamped steel.
  • The boiler consists of: combustion regulator, primary air damper, an ash chamber door, a grave arm of a grate grid, a lever of the bootable damper, a thermomanometer measuring the temperature and water pressure in the heating boiler.
  • With the help of the combustion regulator, the required boiler water temperature is set and its maximum value is limited.
  • The valve of primary air (associated with the combustion regulator) adjusts the air supply.
  • Behind the door of the ashtar is an intrinsic box.
  • Due to the movement of the shaking lever, the grille of the grid is falling into an intrinsic box.
  • Through the loading flap is fuel. In the cold condition, you can clean the boiler through it.
  • To reduce condensation when burning and increasing the service life of the boiler, it is recommended to equip the boiler with the protection mechanism so that the temperature does not fall below 65 ° C (condensate formation temperature).

Connecting to the chimney

  • The boiler in the central heating system must be attached to the independent chimney.
  • Especially important for economical regime Work when burning in a solid fuel boiler to ensure the necessary thrust in the chimney.
Graph of hydraulic resistance

Application area

  • Ideal for heat supply when using cheap solid fuel.
  • Logano S111-2 can be applied as a separate boiler, as well as in combination with a heating boiler operating in gas or diesel fuel. Perhaps the subsequent dustcoming boiler on Gaza / Diztopliva.
  • Logano S111-2 works without using auxiliary energy and can be operated in the absence of voltage in the network.
Boiler design and features
  • Seven sizes - starting with 12 kW - allow you to choose smoky pipe In accordance with the power of the boiler.
  • The boiler can be used without a pump; due to the difference of temperatures hot and cold water Either with forced circulation of hot water with a maximum operating pressure of 2.5 bar.
  • Large loading door and impressive sizes of loading mine boilers Logano S111-2 45D allow loading of large-sized wood.
  • The large volume of the loading space of the combustion chamber guarantees a long combustion process.

Universality of application due to the possibility of burning large pieces of fuel

  • The main applied fuel:
    - for boilers Logano S111-2 12, 16, 20, 24, 27, and 32 - brown coal nut (20 - 40 mm), heat of burning 16 MJ / kg, maximum humidity 28%;
    - for boilers Logano S111 32D and 45D - firewood, heat of burning 16 MJ / kg, maximum humidity 28% (length is full to 0.33 m and 0.53 m, respectively for sizes 32d and 45d, maximum diameter 0.1 m)
  • It is possible to use other types of solid fuel (secondary), but it is necessary to maintain the operating parameters of the boiler the same as for the main fuel:
    - brown coal nut 2;
    - brown coal in briquettes;
    - pressed fuel;
    - coal;
    - Coke.
  • When using fuel, local requirements should be observed.
Equipment
  • For heating heat supply installations for DIN 4751-1 and DIN 4751-2.
  • Steel heating boiler.
  • The package includes: an rally drawer; scraper for cleaning; ash knife (absent from boilers type 32D and 45D); combustion regulator; cone for combustion regulator; Sealing cuff for combustion regulator; Chain lever for burning regulator; plug with thread g 1/2 "; a tap for filling and draining with thread g 1/2"; chammed bricks, the amount depends on the size of the boiler; airborne; Scraper for cleaning channels of secondary air (absent from boilers type 20, 24, 32D and 45D).
  • Logano S111-2 can be used as a separate boiler, as well as in combination with a heating boiler operating on gas or diesel fuel. Subsequent daunting is possible.

Price Retail: Add to Cart, Pieces: Delivery:

From ~? ~ Rub.

  • Steel heating solid fuel boiler, designed for heat supply apartments, cottages and administrative buildings
  • Used as a separate boiler or combination with a heating boiler operating on gas or diesel fuel
  • Suitable for use in pumping or gravitational systems
  • Narrow overall dimensions allow the use of a boiler in small rooms
  • Built-in heat exchanger as an additional option
  • The long combustion process is ensured by large volumes of the loading chamber and the ash
  • A wide range of applications due to a variety of fuel selection. It is possible to use other types of solid fuels: coal and coke
  • Trouble-free installation in already existing systems
  • Boilers Logano S111 32D and 45D are designed specifically for use as a fuel of wood; The length of the PLAN can reach up to 33 and 53 cm in length, respectively.
  • Easy access and simplicity of cleaning of flue space
  • It is applied for open Systems or for closed in combination with a tank-drive, as well as for closed systems in combination with the protective thermostat-valve STS 20
  • S111 WT boilers are equipped with a built-in heat exchanger to protect against overheating in closed systems

Article 30009350 Fuel Type Solid installation type Floor thermal power, kW 45.0 Heat exchanger Material Steel Number of contours Single-circuit fuels Brown coal, wood, briquettes, Cox Power modulation, kW 18.0-45.0 Power supply, in non-volatile average efficiency,% 73- 82 Boiler water temperature, ° C 95 Automation included No display No Water connection (straight line), G "1 1/2 Water connection (arr. Line), G" 1 1/2 Diameter of chimney, mm 180 height, mm 1045 width, mm 688 depth, mm 980 Weight without water, kg 320 Country of origin Czech Republic Warranty 1 year

Type of fuel

Types of fuels of heating boilers are divided into gaseous, liquid, solid, or substance, incinerated to heat.
Among the heating boilers in a separate group you can endure the same electric boilers - The most eco-friendly of all types of boilers.
The cheapest, today, the type of fuel in Russia is natural gas. Followed by solid fuel, Electricity and diesel brass.

Boilers designed to work on gas are usually tuned to the main gas - methane, but in the absence of a main gas, they can be converted to work on liquefied gas - A mixture of propane-butane.

Liquid fuel is diesel fuel, fuel oil, synthetic oils. In everyday life used diesel fuel - diesel fuel. Today it is one of the most expensive types of fuel. As a rule, it is resorted to its use in the absence of a main gas and sufficient for heating of electrical power.

Solid fuels include firewood, coal, peat, pressed sawdust (pellets). These fuel types are relatively cheap (depending on the specific conditions of the region).

type of instalation

The type of installation of heating boilers is divided into wall and outdoor.
The installation type is determined constructive device boilers, their power, as well as the type of fuel used.

Recently, gas and electric wall boilers, in which, as a rule, are all necessary elements "Boiler": pump, expansion tank, security group, automation, heat exchanger for DHW, etc.

Thermal power, kW

Nominal thermal power is the power that can be removed from the boiler directly to heat the trimmer, i.e. This power takes into account the loss of heat (efficiency).
Nominal thermal power is measured in kilowatts (kW). The higher the efficiency of the heating boiler, the less the difference between its nominal thermal power and thermal load.

Heat exchanger material

Heat exchangers of heating boilers are manufactured from different materials.

W. outdoor models Heating boilers They are usually made of steel or cast iron. And steel and cast iron have both their advantages and about the shortcomings and speak unequivocally about the benefits of this or that material incorrectly.

Wall-mounted heat exchangers are most often made of copper and stainless steel. And the first and second have high reliability and durability. Sometimes on copper heat exchangers Special coating is applied to the increasing service life.

Number of contours

The number of contours (separately controlled branches) equipped with pumps, mixing devices or non-controlled branches equipped with pumps or without a distribution manifold of the boiler installation. One of the systems is connected to each branch: radiator heating, warm floor, hot water heating, pool heating, etc.

Most models of modern gas wall boilers have two contours.
One for heating, the second for heating hot water. Such devices allow to obtain and heating and hot water using one compact device. If it is necessary to expand the number of contours, for example, for warm floors, mixing groups are installed.

At the classic floor boilers out the contour one. Additional contours are obtained using a distribution manifold and mixing groups of automatic controlled.

Power modulation, kW

Power modulation (kW) - Automatic burner power control to ensure the most economical boiler operation. Power modulation is used in wall and condensation boilers.
The power modulation range shows in what limits of the burner can change its thermal power.

Medium efficiency,%

The average efficiency (%) is the average efficiency of the boiler installation for the year.

Boiler water temperature, ° C

The boiler water temperature (° C) is the temperature to which the coolant warms up in the boiler.

Automation in the kit

Automation included - automatic electronic device for managing boiler equipment operations, built into the design of the heating boiler or supplied with the boiler.
There are many different types Automation. One of important indicators - The number of contours of the heating system which can control the automation.

Display

Display - screen to obtain visual information about the operation of the equipment, the temperature of the coolant and error messages.

Chimney diameter, mm

Ø chimney, mm - minimal diameter of gas pipes and chimney. This size is indicated in the passport of the boiler.

Understatery of the smoke cross section absolutely forbidden!

With household walls gas boilers The fan burner uses coaxial (tube in a pipe) chimneys, allowing you to bring fresh air to the boiler and removing the spent gases from the boiler.

Installation

Installation of boiler room includes:

Installation and fixing the boiler in place;

Connecting a boiler to a central chimney or connecting a set of passage through the wall;

Connecting a boiler to heating pipes;

Installation of protective equipment (security groups, expansion tank)

Installing a coarse filter;

Installation of a drain valve;

Connecting the feed line;

If necessary, installing a boiler pump, a submersing pump, a hydraulic separator, a distribution manifold;

If necessary, partial assembly / disassembling the boiler

Installation and connection of one heating group (each subsequent - 5000 rubles);

Filling the heating system by heat carrier;

Adhesive heating system.

Installation of the water heater includes:

Installation and fastening of the water heater in place;

Direct loading line device from the boiler with its pump;

Connecting a water heater to cold and hot water lines;

Device by the need for a recycling line;

Installing protective equipment (security groups, expansion tank);

Installation of a drain valve;

Installation of shut-off reinforcement and instrumentation;

If necessary, installation of thermal insulation casing;

Filling the water supply system with water;

Filling the heat exchanger line by the coolant;

Pressing the heating and water supply systems.

Stacking

Commissioning works include:

Checking the correct installation of all equipment

Checking system for tightness

Checking grounding

Connecting the boiler to the gas highway (diesel)

Installation and electrical installation of weather-dependent automation (with its presence, an additional 6000 rubles + 1000 rubles for each additional circuit)

Setting up automation

Setting the combustion process

Check and adjust the boiler operation in all modes

In commissioning works also includes detailed instructions of those responsible for operating the boiler installation.

After commissioning, the equipment is placed on the warranty.

Annual service

Service maintenance includes :

Diagnostics of boiler equipment

System feeding, podaching of expansion tanks (if necessary and availability of service cranes)

Cleaning the coolery chamber of the boiler unit

Control and adjustment work on the burner

Control and Adjustment Works on the Automatics System

Cleaning mud filters

Operational service for emergency calls of the Customer (Departure, Diagnostics, Repair)

The cost of annual service includes the cost of the listed works and the cost of spare parts that are supplied free of charge for warranty or for a fee is not included. Annual service is a prerequisite for preserving warranty obligations.

Boilers Buderus Logano. S111 work on any solid fuel. This makes them one of the most functional on the market. Consider the features of these boilers and the feasibility of such an acquisition.

Features of boilers Buderus Logano S111

The boilers of this series are made of different sizes and capacities offered, from 12 to 45 kW. Due to the design features, it became possible to combine boilers with heating boilersGas or diesel fuel. In addition, the line of models of Buderus Logano S111 found its application and in pumping systems. Some models already in the factory configuration go with the built-in heat exchanger protection and blocking system in order to avoid overheating of the boiler.

To date, the market shows the following Buderus Logano S111 models:

  • Logano S111 12
  • Logano S111 16
  • Logano S111 20
  • Logano S111 24
  • Logano S111 25max
  • Logano S111 32
  • Logano S111 32D,
  • Logano S111 45D.

The numbers after the index "111" denote the maximum power of a solid fuel boiler in kilowatts. All models have a combustion chamber open type, wherein hot water Served in the heating system by one-circuit scheme. The symbol "D" denotes models with an increased furnace, as a source of energy in which wood and lamps are used up to 50 cm long. Wood moisture in this case should not exceed 28%. The efficiency of all models is from 72 to 82% depending on the quality and type of fuel used.

Due to the presence of a roller and surround combustion chamber in the boiler for the heating of the room, it is necessary to bookmark the fuel just twice a day.

Characteristics of boilers Buderus Logano S111

All models of the Buderus Logano S111 series are distinguished by high efficiency and good characteristics. Thanks to a wide model range, it became possible to choose the model to your taste:

1. Logano S111 12:

  • minimum power / nominal: 7/13,5 kW,
  • KPD: 80%,
  • Fuel consumption kg / h: 3.2.

2. Logano S111 16:

  • power minimum / Nominal: 6/16 kW,
  • KPD: 80%,
  • Fuel consumption kg / h: 4.7.

3. Logano S111 20:

  • minimum power / nominal: 6/20 kW,
  • KPD: 76%,
  • Fuel consumption kg / h: 6.

4. Logano S111 24:

  • minimum power / nominal: 7/24 kW,
  • KPD: 76%,
  • Fuel consumption kg / h: 7.6.

5. Logano S111 25MAX:

  • minimum power / nominal: 8/27 kW,
  • KPD: 76%,
  • Fuel consumption kg / h: 7.9.

6. Logano S111 32:

  • power minimum / nominal: 9/32 kW,
  • KPD: 76%,
  • Fuel consumption kg / h: 8.9.

7. Logano S111 32D:

  • minimum power / nominal: 9/28 kW,
  • KPD: 78%,
  • Fuel consumption kg / h: 8.4.

8. Logano S111 45D:

  • minimum power / nominal: 18/45 kW,
  • KPD: 82%,
  • Fuel consumption kg / h: 14.

To ensure constantly high performance, it is necessary to take care of a good thrust in the chimney.

General information about boilers Buderus Logano S111

Even a special search for negative reviews about boilers did not give anything. Although it would seem for more than a three hundred years of the existence of the brand were to manifest themselves and flawed. However, no matter how difficult it was to believe in it - there is no negative information.

For all modern models Boilers operates the factory warranty in 2 years at the time of launch. With proper use maintenance Required once a year, and during the warranty, the installer is carried out.

Of course, quality costs money. On the other hand, the miser pays twice and easier once to buy reliable and durable equipment than to change components every year.

Technique requires appropriate maintenance, so when purchasing a boiler, it is necessary to carefully examine the instruction manual. In terms of heating, this boiler can stall except that only the choke cartridges, which at the price value on average five times less heated house no worse, and the time spent on heating is less. Hence the conclusion: it is first to consult with several specialists to determine what is still the type of the boiler for heating to put in your home.

  • Steel automatic boiler operating on a brown / stone coal or pellets with a fuel bunker, designed to 50 hours of operation on one load of fuel, and a roller designed for 12 hours of operation
  • The volume of the fuel tank is 240 liters. Opening hours on one download (coal) up to 50 hours. Optional ability to increase the volume of fuel tank. Available as an accessory and can be installed after the purchase of the boiler
  • The possibility of installing the bunker for fuel both to the right and on the left already in the basic configuration without any additional options.
  • New heat exchanger with a high heat transfer coefficient. Efficiency - up to 88%, corresponds to the environmental class 4 in accordance with EN 303-5
  • For systems with natural and forced circulation of the coolant, with open and closed expansion tanks
  • Recommended fuel: - stone coal of a fraction of 10-30 mm; - brown coal of a fraction of 10-25 mm; - Pellets
  • The heat exchanger of the boiler, the burner and fuel auger are made of special high quality steel
  • The built-in automation system controls the PID regulator, the fuel supply intensity, the frequency of rotation of the air supply fan, the pump of the heating system, as well as the water heater loading pump
  • Advanced method for regulating the burning process depending on the temperature of the feed line in heating system and the temperatures of outgoing flue gases
  • Smooth adjustment of air supply fan speed
  • Produced in three sizes - with a nominal power of 15, 20 and 25 kW

Buderus Logano S111-2 Heating Copper 16

Solid fuel boiler Logano S111-2 It is used for heat supply apartments, cottages, administrative or industrial buildings As the main or autonomous heat source. You can use wood, briquettes, brown coal or coke as fuel. Suitable For use in systems with natural and forced circulation of the coolant, with open and closed expansion tanks. The lineup Presents the nominal capacity of 12-45 kW.

Small boiler dimensions allow it to be easily installed in a new or existing heating system. It is easily combined with boilers working on diesel fuel or gas.

Despite the small area used for installation, the upper boot chamber (providing the nominal boiler performance) is designed to supply lanes up to 53cm long. Which are loaded through the upper part of the boiler. The large volume of the combustion chamber and the ashtar provides a long combustion process. The combustion chamber with top loading and shaking grate grille provide convenience during operation and maintenance.

The boiler is equipped with an automatic thermostat for controlling the combustion intensity and temperature sensor to control the temperature of the coolant. Possible equipment of a boiler with a heat exchanger for additional protection from overheating.

Features and advantages of the boiler Logano S111-2:

  • Modern design
  • Ability to use on different types Fuel: Wood, Coal, Briquettes
  • Easy to operate and maintain
  • Convenient installation of heating
  • Easily combined with heating boilers on various types of fuel
  • Eight sizes 12-45 kW
  • Big combustion chamber with top loading
  • Shake grate grate
  • Spacious ashpan ensures easy cleaning
  • The possibility of applying in open and closed systems with coolant circulation
  • The possibility of equipping an additional protective heat exchanger for a hermetic system
  • The design of the boiler is made in accordance with the rules EC 303-5.3

Design and conditional designations in the scheme, see Fig. 1.2: