Error codes are needed if your split system has breakdown, how to fix the problem that you need to know including the consumer that would not be inflated in the service center.
Possible breakdowns refrigeration technology Defined by error codes, it is not necessary to be a specialist to determine the cause of the cause of failure
The main directions of troubleshooting are simple ... If the error code F-1, F-2, F-3, F-4, F-5, F-6, F-7, F-4, F-5, F-6, F-7 is displayed, etc. The problem must be sought in temperature sensors. And all that is associated with them on the control board, the signal, break or short circuit, does not pass.
If the error code E-1, E-2, E-3, E-4, E-5, E-6 ..., etc. is displayed. E-0, EL, while air conditioning or starts and works for some time, or does not start at all, then we are looking for a solution to the problem with the work of the System Systems in the Power Part: Causes are different ... From the full not passing the signal to start to critical current characteristics on the system shutdown .
As an example: the bearing of the fan of the indoor unit, the fan impeller rotates but with insufficient speed, the Hall sensor or the torque sensor does not supply the control signal, split the system after 1-5 minutes it gives an error E 1 ... E-L, the problem is found.
Toshiba air conditioning systems are easy and simply in the presence of a service manual, we provide you with free opportunity to be at least a little, but smarter.TOSHIBA RAV Series - Air Conditioners or Error Codes Problems
But, if all the same, your Samsung had trouble, - Samsung broke, do not hurry to call service center On repair of air conditioners, try moving the air conditioner board and return the SAMSUNG split settings to the factory.Samsung - air conditioning fault codes | Self-firmware female
Mitsubishi, Fujitsu, Acson, Dantex, Mitsubishi-Heavy, Chofu, Akira, General Electric, General Climate, Gree, General-Fujitsu, Sanyo, Daikin, Toshiba, Electrolux, Kentatsu, Neoclima, Midea, McQuay, Panasonic, Aux, West, Whirlpool, Yamaha, Euronord, Pioneer, Mitsubishi-Electric, Hyundai, Dantex Classik Toyo, Chigo, Dax, Roda, Renova, Quattroclima, Lessar, Supra, Saturn, Ferroli, Hualing, Tadiran, Daewoo, Airwell, York ...
If you did not find your air conditioner in this long list, do not worry, click on the source link ... there is everything there.
ERROR CODE AIR CONDITIONING | Error codes, originals PDF fileP1 Inspection of the thermistor room temperature (RT1) 1) Bad contact of the thermistor 2) Damaged thermistor 1) Check the thermistor. 2) Measure the resistance of the thermistor. Normal resistance should be the following. 32 ° F-15K | 86 ° F ..... 4.3K 50 ° F ...... 9.6k 104 ° F ..... 3.0k 68 ° F ...... 6.3K, if the resistance is normal, replace the internal council dispatchers. P2 The internal thermistor of the coil (RT2) P3 signal transmission error (the remote dispatcher does not respond to the internal controller signal.) 1) Bad contact of the transmission wire 2) The signal transmission / receipt of the signal is incorrect. 3) Incorrect operation due to noise waves emitted by other devices
1) Check the transfer wire. 2) Consider with another remote dispatcher. If "P3" is still designated, replace the inner board. If another cell code appears, replace the original remote controller. 3) short circuit between and from CN40 and attached CN40 to the following units. Second unit in double control second and third units in triple control units sub in control group P4 abnormality of leakage sensor 1) bad contact contact telegraphsAir Conditioners Mitsubishi-Electric | Faults of split systems, error codes
Frequent breakdowns of air conditioners of the budget series are due to the fact that the split-systems of lower price category breaks much more often, since almost all nodes, parts, coolers mechanisms are minimized.
Error codes of air conditioners groups - Dax, Jax, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu, Renova, - with interchangeable printed circuit boards.
Error codes whole groups budget air conditioners- Dax, Jax, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Vitek, Daihatsu, Renova, with interchangeable printed circuit boards. Firmware Cooling Data Cooling Default Data Devices.
E1 or EL - carefully attribute to this malfunction in the operation of the air conditioner, it is usually not related to the quality of the cooler, it is external error Systems associated with poor-quality voltage in the power supply network.
Error display code | Aux, Dax, Jax, Pioneer, Hansa, Saturn, Vitek, Rolsen, Yamatsu, DaihatsuDisplay readings on the remote control Mitsubishi.
EA error code Why does not work Mitsubishi? Incorrect installation of the inner / external, block. exceeds the number of internal inclusions, connecting block, breaking. Check the temperature and pressure sensors ...
Error code EB Fault Split system. Incorrect installation of the inner / external, block. (Incorrect installation, check the correct connection) Check the temperature and pressure sensors ...
EU Error Code Problem. Run in time, start delay. Check the temperature and pressure sensors ...
Error code E6 malfunction. Internal / outdoor, - control board fault (signal receiver does not work). When checking is closed,
Error code E7 MitSubishi air conditioner fault. Internal / outdoor, - incorrect signal generation (not proper compound, breaking, closure). When checking is closed,
Error code E8 malfunction air conditioner Mitsubishi-Heavy. Internal / outdoor, - control board fault (signal receiver does not work).
Mitsubishi-Heavy, eliminating the cooling circuit faults.
Eliminate the cooling circuit faults.
Check the temperature and pressure sensors ...
Error code E9 conditioner fault. Internal / outdoor, - incorrect signal generation (not proper compound, breaking, closure). Check the temperature and pressure sensors ...
MitSubishi-Heavy cooling systems malfunction, service manualSearch faults and breakdown split systems McQuay / ACSON. , It is necessary to start with the total causes of breakdowns and equipment failure. Total reasons can be attributed to the fault of the electrical part and the malfunction of the refrigeration circuit.
McQuay / ACSON equipment, their analogues and modifications.
McQuay ... McQuay and ACSON, - Possible malfunctions and errors
If you have broken the air conditioner Carrier, then something extraordinary and leaving beyond the scope of mind occurred.
Carrier, - are so reliable and durable that break this device Extremely difficult even with a big desire. But, anyone happens ... Meteorites fall ... Faults Split Carrier systems
As a rule, the main fault of LG air conditioners is the insufficient voltage of the electro-consumption network. Chubasyt spoil LG air conditioners. How to fix the breakdown? How to determine the malfunction using blinking indicators. What do this morgue mean?
How many times the indicator light was blinking, you can see the focusing on the drawing above. How to find an error using indicators - LEDs of the indoor unit of air conditioners.How many times the indicator light was blinking, you can see the focusing on the drawing above.
Haier air conditioners are also broken as well appliances, fault codes and possible mistakes In Split systems of this brand, you can easily determine the faults table shown on the page of our site.
Algorithm of operation of air conditioners Haier Electric Corporation is so simple that even a novice amateur repairman can understand it.If everyone repair work Conduct consistently, the result is simply obliged to be positive.
Panasonic, repair of air conditioner. We are looking for and correcting the errors of the system. Error and fault codes Panasonic air conditioners (Panasonic).
The breakdowns and problems of split systems under the well-known multi-national National Panasonic brand, as well as the main faults of the Systems are presented in our repair of chillers of this type.
If your Panasonic flashed like christmas tree And it does not want to perform commands set by the air conditioner control panel, then this article will help to figure out and eliminate an unexpected problem. All repairs! Even split system National Panasonic. For example, we note that Panasonic air conditioners break too.
We are looking for and correcting the errors of the system. Panasonic error codes.
In order to order the repair of the Panasonic air conditioner, it is enough to call our operator and leave an application. ... Repair of air conditioners Panasonic. Name of service. Price, rubPanasonic, repair of air conditioning | We are looking for and correcting the system errors
Gree, like air conditioning, is simple functionally, therefore there are not many error codes. Disadvantages of simplistic gREE air conditioners- These are weak control card varistors, insufficient smoothing of currents during voltage cast. Trifle, but it should be due to the repair of air conditioners GREE. And their analogues.
It seems that everything is also repaired: it is only necessary to gain a little patience of confidence in the success of the company on repair. Everything will be fine...Gree: error and fault codes | Simple repair
Daikin Error codes ... Faults of these glorious air conditioners Daikin Daich. Table definition of conditioner faults Daikin.. Full image size. 2500*2000 link.
Self search for malfunction errors Daikin air conditioners. Preparency diagnostics Split Daikin system.Daikin Error codes | Fault of air conditioners Daikin
We see in the book we see ... what you need. Paradox faults Fujitsu, GENERAL-FUJITSU. FUJITSU Split Systems Fault Codes, General-Fujitsu. Fujitsu, General-Fujitsu, Fuji. Air conditioning fault codes, system error control or System Controller Error Fujitsu. When EE: EE is displayed on the Fujitsu remote control, press the power saving and the button change button simultaneously hold the buttons for more than 3 seconds. Error codes will be shown on the display. (1) Stop the operation of the air conditioner. (2) Press the control wizard button and the fan control button at the same time for 2 seconds or more to start the test start (3) Press the Start / Stop button to stop the error test starter \u003d 01 Fault \u003d Communication Error (Internal block with outdoor unit) Error code \u003d 02 Fault \u003d Room temperature sensor Open, error cluster \u003d 03 Fault \u003d Internal unit temperature sensor, - short circuitry error \u003d 04 Malfunction \u003d Open the temperature sensor of the internal unit of the air conditioner. Code of error \u003d 05 Fault \u003d The internal block temperature sensor is faulty. Sensor resistance 10 ohms. Error code \u003d 06 malfunction \u003d external heat exchanger temperature sensor opencode error \u003d 07 fault \u003d outer heat exchanger short circuit sensor temperature error temperature \u003d 08 fault \u003d power to connect to source error error \u003d 09 Malfunction \u003d Float switch running error \u003d 0a malfunction \u003d outdoor unit temperature sensor Open or Open error \u003d 0B Malfunction \u003d Outdoor unit temperature sensor Split system, - short circuit Collection Picture Picture Manual Fujitsu, General-Fujitsu. Original. Fault \u003d No signal from Fujitsu, NOT NOT Normallyode Error \u003d 14 Malfunction \u003d No Signal with room sensor 2. FUJITSU Outside LED Block. When the outdoor temperature drops, there is not enough pressure in the system. Add freon. Error: Heat and cooling (reverse cycle) Incorrect connection Fujitsu.
Both domestic and industrial systems air conditioning, in most, have the function of self-diagnosis. This feature can operate automatically or in a special, if malfunction with equipment occur. As a rule, information with error codes can be observed on the displays located on the internal blocks of split systems. Thanks to this data, faults are precisely determined, due to which disorders occurred in the air conditioning system. To independently determine the causes of problems in devices of different manufacturers, you can use the lists of error codes of various air conditioners provided below by brand names.
In the LG air conditioning systems, the microprocessor is detected by any problem. locking the launch of the aggregate, after which the signals flaring the LED, which report the error code.
If the system has discovered several problems, then one breakdown is induced, which has the smallest sequence number. After that, the fault indication is in ascending order. The table provided below shows the light codes of error errors LG, and deciphered that each of them means.
You should know: the emergence of similar errors can be provoked by unsatisfactory parameters electrical network, or by a random failure that occurred in the unit electronics. Therefore, do not rush to immediately contact the service, but simply de-energize the device and check electrical voltage. It is also necessary to make sure that it is correctly selected device operation mode. After these checks, you can turn on the device. Most often, this method helps in solving this problem, and it no longer appears.
A set of fault designations detected by a microprocessor depends on the model of the unit. For LG air conditioners, another indication may be in the form of numbers and letters.
Evaporator block faults:
Confers block defects:
Designations in the units LG Art Cool:
Daikins are pretty complex equipment (from a technical point of view) and, except refrigeration unitThere are electronic control cards, many different sensors and valves, power inverter and other nodes. At the failure of any component of the device, it is difficult to find the cause of the breakage without a special function that allows you to diagnose the equipment. This procedure is carried out using the remote control, and the error codes of Daikin air conditioners when the device fails, you can see on its display.
Evaporator problems Daikin equipment:
Faults in the system:
Other malfunctions:
Panasonic air conditioners error codes are usually highlighted. on the displayLocated on a wall (room) unit of the aggregate. You can find them if you press the "Check" button on the remote control, and hold it at least 5 seconds.
Since instead of a button on the remote control, only a hole is visible, then for pressing a recessed button, you can use the stationery clip, if it is accelerated, or a small carnation.
After the remote control in the control mode of the air conditioner error Panasonic, hover it towards the room unit and press the buttons to control the timer (up "and" down "arrows), start sorting out the codes starting from" H00 "and then by order. When the malfunction code is coincided in the wall block memory and on the remote, you will hear sound signal. To exit the check mode, press the "Check" button.
Deciphering values \u200b\u200bfor Panasonic aggregates:
The Toshiba Ras cooling system remote control also has a "Check" button, which includes self-diagnostics of the unit.
Code designation problems in domestic air conditioning systems Toshiba RAS-07S3KHS-EE / RAS-07S3AHS-EE, TOSHIBA RAS-10EKV-EE / RAS-10EAV-EE):
These values \u200b\u200bare also applicable for RAS-10SKHP-ES, RAS-13SKHP-ES, RAS-13S2AH-ES, RAS-07S2AH-ES, RAS-10S2AH-ES, RAS-07SKHP-ES and others.
Industrial Condition Codes Toshiba:
Ballu air conditioner error codes, as usual, highlight on the display House block evaporator. With each inclusion of climate techniques, the microprocessor ball is performed by the equipment self-diagnostics and in the event of a problem detection displays special designations to a miniature screen.
Decryption for Ballu brand devices:
If, when you turn on the air conditioner, the self-diagnostic system detects a malfunction in any device module, then it is instantly blocked. In this case, all error codes of Gree air conditioners can be observed either on the remote control screen, or on the display of the indoor unit of the unit.
List of conditioning units GREE:
Digital-letter designations of problems that are highlighted on the remote control:
Errors that are displayed on the display of the wall block (internal) General Climate:
Some urching codes of GENERAL CLIMATE, given above, allow the user to find the problem independently and fix it. In other cases, for example, if the DEF / FAN indicator flashes (Pre / DEF), the specialist will be required.
To run self-diagnostics of Samsung technology, it is necessary to launch the work of the Condera in test mode. To do this, hold the split system start button for 5 sec. SAMSUNG air conditioner error codes, when they are detected, are displayed on the display of the unit located indoors.
Failures in the work of Split Systems Samsung:
To find faults in technique from Mitsubishi is needed within 4 sec. Hold 2 buttons on the remote control (simultaneously): "Check" and "SET". When troubleshooting, Mitsubishi Electric air conditioner error codes are displayed on the display of the indoor unit or remote control.
In addition to the above, Mitsubishi Electric air conditioner errors are provided universal error codesrelated to different models of MITSUBISHI Electric units:
The tables below are Hitachi air conditioners error codes. In the aggregates of Hitachi, malfunctions are determined by flashing indicators.
Error codes in climatic systems (air conditioners) TCL can be decrypted by using the table below (the amount of flashing LEDs for 8 seconds. Means error code).
In the IDEA units, all problems detected by the processor at start-up are highlighted on the display of the air conditioner.
Air conditioner error codes allow the service engineer to quickly find and efficiently eliminate malfunctions.
This is the first thing to do before its service or repair. Diagnostics of the air conditioner allows you to remove breakage and malfunction in the system. Whether the lack of refrigerant, which must be filled, errors in the air conditioner and malfunction of the main nodes.
Timely and competent diagnosis of problems will allow the service engineer to quickly and efficiently eliminate faults. So, to return a healthy microclimate into the house or office of the client.
All modern air conditioners have a developed self-diagnostic system. As a result of the analysis of the status of the equipment, the system reveals the cause of the fault that has arisen and displays the error code for the display (remote control, board or modes indicator). Below are the codes of air conditioners (Alarm Code) of various brands. Using this information, you can independently read the error code and repair the air conditioner. This will significantly save the time diagnostics of the equipment and will avoid inaccuracies in determining the nature and location of the breakdown.
We picked up information about the codes of air conditioners and split systems of different brands.
If you need an authorized service center for repairing air conditioners - this is to us! Eurobusiness company is your reliable partner!
⊕ - Flashing, 2 - Light, 3 - Do not burn.If there is error data, the operation of the air conditioner will be automatically stopped.
If the Beko air conditioner does not work - this is to us!
If a malfunction is detected, then the green indicator (P) and the orange indicator (R) are blinking with a frequency of 0.1 sec, showing the malfunction code. It should be noted that the orange indicator (R) corresponds to dozens among the fault code. The green indicator (P) corresponds to units among the fault code.
Between the flashing of orange and green indicators takes 2 seconds. The sequence is repeated with an interval of 4 seconds.
For example, a malfunction code 13. The orange indicator flashes once, both indicator turned off 2 seconds, the green indicator flashes three times with an interval of 0.5 seconds, both indicator turned off for 4 seconds.
The sequence is repeated until the fault is eliminated. If the fault code is less than 10, then the orange indicator does not blink.
The code | Description |
2 | Indoor temperature sensor fault |
3 | Malfunction of the temperature sensor of the internal heat exchanger TC |
6 | Fault of the reversing valve of the outdoor unit |
8 | Fat fan malfunction in the inner block |
9 | No power supply to the internal unit |
11 | Fault drainage pump or other drainage problems |
12 | A mistake in software Internal block (incorrect addressing) |
13 | Configuration error |
14 | Loss of signal central system Control |
15 | TCJ internal heat exchanger temperature sensor fault |
18 | Faulty control unit of the outdoor unit (protection against short circuit G-TR) |
20 | Error in block position recognition circuit |
21 | Current sensor fault in the outer block |
22 | Outdoor heat exchanger temperature sensor malfunction |
23 | Discharge Temperature Sensor Fault |
24 | Fault Fan Outdoor Block |
26 | Other outdoor malfunction |
27 | Blocked outdoor compressor |
27 | Invalid discharge temperature |
29 | Fault compressor outdoor unit |
31 | Increased pressure in the outdoor block circuit |
If Carrier air conditioner does not work - this is to us!
If Chigo's air conditioner does not work - this is to us!
Error code | Cause of malfunction |
F6. | PG Motor Faults. |
F7. | Indoor Temp Sensor Faults |
F8. | Indoor Coil Pipe Temp Sensor Faults |
F9. | Outdoor Coil Pipe Temp Sensor Faults |
If the Daewoo air conditioner does not work - this is to us!
Fujitsu General Ltd. Corporation introduced a new product on the market to diagnose split systems and multi-split-systems GENERAL. The tool is a set of adapter connecting outdoor block with a computer and a PC program. With their help, a specialist conducting equipment diagnostics, real-time can see the parameters of the compressor, fan motor, EEV, sensor readings, as well as error log. During the testing process, it is possible to record a work log with a report.
The adapter is suitable for working with multi-split systems, as well as with most inverter split systems (wall, ceiling, channel, cassette).
Modern Fujitsu General air conditioners have a very developed self-diagnostic system, according to the results of which the control system, when a particular malfunction is detected, blocks the operation of the entire device and simultaneously reports the reason for the malfunction.
The Fujitsu General Air Conditioner Management System informs about the faults by flashing the LED on the internal panel (in some cases outside) block. If one or another malfunction of the air conditioner, the LEDs are lit or blink in a certain sequence, which corresponds to the detected error. If the air conditioner control system has detected more than one error, then the fault is first indicated that has the greatest priority, and then all the others.
Cause of malfunction | Display errors | ||
Operation (Red) | Timer (Green) | Swing (Orange) | |
Malfunction of the Internal Block Board | ABOUT | ABOUT | - |
Open the indoor temperature sensor wire (internal unit) | 2 X. | ABOUT | - |
Short circuit in room temperature sensor circuit (indoor unit) | 2 X. | ABOUT | ABOUT |
Open the indoor pipeline sensor wire | 3 X. | ABOUT | - |
Short circuit in the internal block pipeline sensor circuit | 3 X. | ABOUT | ABOUT |
Faulty fan inner block | 6 X. | ABOUT | - |
For some models (see List *) Depending on the error, the Operation, Timer indicators, Swing work on the following principle: ABOUT - Fast flashing; X. - Slow blinking; - Off
* Indoor Unit: ASG18FBAJ, ASG18FBBJ, ASG18UBAJ, ASG18UBBJ, ASG24FBBJ, ASG30FBBJ, ASG18FBBX, ASG18UBBN, ASG24FBBN, ASG24UBBN, AWG18FBAJ, AWG18FBBJ, AWG18UBAJ, AWG18UBBJ, AWG24FBBJ, AWG24UBBJ, AWG30FBBJ, AWG30UBBJ, AWG14UBBJ, ABG14FBBJ, ABG14FBBJ, ABG18FBBJ, ABG18FBBJ, ABG181BBJ, ABG181BBJ, ABG24FBBJ, ABG24FBBJ, ABG241BBJ, ABG241BBJ, AWG24FBAJ, AWG24BAJ.
* External power: AOG18FNAK, AOG18FNBK, AOG18UNAKL, AOG18UNBKL, AOG24FNBK, AOG24UXBKL, AOG30UNBDL, AOG18FNBX, AOG18UXBXL, AOG24FXBX, AOG24UXBXL, AOG18FNAK, AOG18FXBK, AOG18UNAKL, AOG18UXBKL, AOG24FNBK, AOG24UXBKL, AOG30FNBDL, AOG30UNBDL, AOG14USBJ, AOG14FNBK, AOG14FXBX, AOG18FNBK, AOG18FXBX, AOG18UXBKL, AOG18UNBNL, AOG24FNBK, AOG24FXBX, AOG241XBKL, AOG24UXBXL, AOG24FXAD, AOG24UXADL
If the Fujitsu General air conditioner does not work - this is to us!
Repair of air conditioners Haier (Hyer) is based on the analysis of operating parameters of devices and fault codes.
If there are no errors and malfunctions, but the block does not start, perhaps the launch conditions do not match the required. In this case, the following backup codes will be displayed on the master block display:
Display display | Number of flashes LED5 / Timer | Fault description |
01 | 1 | Tai ambient temperature sensor malfunction |
02 | 2 | Malfunction of the heat exchanger temperature sensor TC1 |
03 | 3 | TC2 heat exchanger temperature sensor fault |
04 | 4 | Double power source temperature sensor malfunction |
05 | 5 | Error EEPROM Internal Block Board |
06 | 6 | Lack of communication between internal and outdoor blocks |
07 | 7 | Lack of communication between the indoor unit and wired remote control |
08 | 8 | Condensate removal error |
09 | 9 | Duplication of the address of the indoor unit |
0A. | 10 | Duplication of the central address of the indoor unit |
Fault Codes External Block | 20 | The corresponding fault of the external block |
Display display | Error code | Fault description |
20-0 | Error on the sensor T protection from the frost of those1 | The AD value is less than 11 (the circuit open) or more 1012 (the circuit is closed) more than 60 seconds. In cooling mode, if the sensor is faulty, the unit does not use its readings, with the exception of the exhaust function or for 3 minutes. after its end; There is no alarm |
20-1 | Error on the TE2 Reference Sensor | |
21 | Outdoor air temperature sensor error | |
22 | TS suction temperature error TS | The AD value is less than 11 (the circuit open) or more 1012 (the circuit is closed) more than 60 seconds. In the thawing mode or for 3 minutes. after its end; There is no alarm. |
23 | Error on the discharge temperature sensor TD | After a 5-minute operation of the compressor, the AD value is less than 11 (the contour open) or more 1012 (the circuit is closed) more than 60 seconds. During startup, in the thawing mode or for 3 minutes. after its end; There is no alarm |
24 | Error on the TIL oil temperature sensor | The value of AD is less than 11 (the circuit open) or more 1012 (the circuit is closed) more than 60 seconds, (the circuit is closed) for 60 seconds; If for 5 minutes, that 2 -10 ° C or em< -10®С, сигнала тревоги нет. |
The tables contain only some fault codes of Haier air conditioners. We remind you that Haier air conditioners are technically complex equipment. Error codes are provided for qualified and certified specialists. That is, for those who are professionally engaged in the repair of air conditioners Haier, and not for ordinary users. Trust repair air conditioners Haier professionals.
If the Haier air conditioner does not work, this is to us!
When a malfunction occurs, press the SLEEP button on the remote control 4 times the error code on the 7-segment display (see table below). If several errors, then press the SLEEP button again - the LED indicator will turn on with the following error code.
The updated remote control, which has 4 Sleep button modes, allows you to set 4 different combinations. When used to verify error codes, you must click on the "Sleep" button 10 times. After that, error codes will be displayed.
The code | Cause of malfunction |
1 | Outdoor heat exchanger temperature sensor error |
2 | Temperature sensor error in compressor injection line |
5 | Troubleshooting Integral Power Module (IPM) |
6 | Trigger protection device from elevated or low voltage in AC network |
7 | Communication error between internal and outdoor blocks |
8 | Overload protection device |
10 | Communication error between two chips (control and drive) in printed |
11 | Memory Error ESPPE Outdoor Block |
12 | Troubleshooting protection device at low outdoor temperatures |
13 | Triggering the protection device as a result of elevated temperature in |
14 | Outdoor temperature sensor error |
15 | Treatment of thermal protection compressor overheating |
16 | The operation of the heat exchanger protection device from frost or overload during the operation of the internal unit in heating mode |
17 | Reactive Power Compensation Device (PFC) |
18 | DC Compressor Start Error |
19 | Compressor drive error |
The code | Note |
SN | Fault of the liquid pipe thermistor |
CJ. | Malfunction of temperature sensor |
E6. | Limitations of temperature protection frequency on the suction tube "TS" |
E7. | Protection frequency limitations average temperature external condenser |
E8. | Protective stop of an external capacitor |
E9. | Compressor frequency limitations over high temperatures |
F4. | Low Pressure Sensor Machines |
F5 | Low pressure sensor protection limitations for ultra-high or low frequency ultra |
F6. | Protective stop by low pressure sensor for ultra-high or ultra-low |
H8. | Protection against overload compressor with constant frequency 1 |
H9. | Protection against overload compressor with constant frequency 2 |
ON THE | Protection against overvoltage and input voltage |
Ns. | Incorrect sequence of the phases of the compressor with a constant frequency 1 |
HH. | Incorrect compressor frequency converter phases |
Hj. | Incorrect phase sequence compressor with constant frequency 2 |
J4. | Communication error with control panel and fan engine |
J5 | Error installing addresses or external block load settings |
38 | Radiator temperature protection frequency limits |
39 | Radiator protective stop |
3A. | DC Fan Protection |
3S. | DC Fan Overvoltage Protection |
3N | Enable error or asynchronous mode Fan work |
3J. | DC fan voltage protection protection |
E2 - Room temperature sensor malfunction
EC - evaporator temperature sensor malfunction
E4 - Fault of the outdoor temperature sensor
E6 - malfunction of the outdoor unit
E7 - Error EEPROM
E8 - Water excess
E0 - faulty room temperature sensor
E1 - defective evaporator temperature sensor
E2 - Faulty Outside Block Temperature Sensor
E3 - faulty outdoor unit
E4 - Drainage pump temperature sensor faulty
E5 - Error EEPROM
E6 - Water Rising
P4 - heavy protection Evaporator of the inner block
P5 - heat protection condenser external block
P9 - Protection of the defrosting function or creating a comfortable air flow
E1 - breakdown or short circuit circuit of temperature sensors T1
E6 - Outdoor Block Protection
Models: KSGH / KSRH21CFDN1 KSGH / KSRH26CFDN1, KSGH / KSRH35CFDN1, KSGH / KSRH21HFDN1, KSGH / KSRH26HFDN1, KSGH / KSRHFDN1, KSGH / KSRHFDN1, KSGH / KSRHFDN1 KSGH / KSRHFDN1
E1 - EEPROM error (non-volatile memory on the board)
E2 - Transition Error through Zero Crossing Error
EC - anomalous fan speed
E4 - Cleaning compressor worked 4 times
E5 - Internal Air Temperature Sensor Closed / Out
E6 - evaporator temperature sensor closed / torn
P4 - Protection by evaporator temperature
P5 - protection on the temperature of the condenser
P7 - the discharge temperature is too high. Confessor protection
P9 - too low temperature Outdoor air, when improving protection will turn off automatically
P10 - Output pressure protection
P11 - Suction Pressure Protection
P12 - Protection against current overload
E1 - T1 internal air temperature sensor closed / clouded
E2 - Evaporator Temperature Sensor T2 Closed / Out
E3 - Capacitor Temperature Sensor T3 Closed / Out
E4 - Outdoor air temperature sensor closed T4 closed / clouded
E5 - broken connection between internal and external blocks
E6 - External Block Protection
E10 - Compressor Suction Pressure Error
E13 - Compressor Phase Error
E14 - incorrect compressor phasing
HS - Strusting
If the Kentatsu air conditioner does not work - this is to us!
The code | Cause of malfunction |
F01 | Open / closure Room room (air) internal block temperature sensor |
F02 | Open / closure Pipe internal block temperature sensor |
F03. | Lack of communication between the control panel and the main control board of more than 2 minutes |
F04 | Open / Closing Pipe External Block Temperature Sensor |
F05 | Open / Closing Room Air Sensor Outdoor Temperature Sensor |
CH01 | Malfunction of one of the thermistors of the board (gap or short circuit) of the inner room, the wall block split system - control of the temperature of the incoming air and the air conditioning gas circuit tube |
CH02. | Malfunction of one of the thermistors (gap or short circuit) of the outdoor unit: the temperature sensor of the incoming air or the temperature of the gas circuit tube |
CH03. | Air conditioning works at the same time and on heating and cooling air |
CH04. | Overload Compressor Protection System included |
CH05 | Error exchange of data between room and exterior blocks of split-system |
CH06 | Current consumption of one or more executive devices of the outdoor bloc - relay, briefly was higher than the norm |
CH07. | Current consumption of the entire outdoor unit for a long time was higher than the norm |
CH08. | Motor malfunction fan |
CH09. | Malfunction of the 4th undercoming valve |
CH10 | The thermistor of the compressor body control temperature control is faulty, the split system (break or short circuit) |
LGMV is a mobile application developed by the manufacturer for remote monitoring of operating parameters of LG air conditioning systems. The application helps engineers evaluate the current state of the equipment. The analysis is made on the basis of a long-term operating cycle. The program helps not only to quickly identify problems in the system, but also issues recommendations for solving the issue.
The LGMV diagnostic system ensures control of the system operating parameters, prevention and prevention of system faults. All this certainly simplifies the diagnosis and commissioning work. LGMV consists of a wireless communications module and a free smartphone application. To use the LGMV mobile application, the Bluetooth exclusive module is required, the corresponding connector of which must be connected to the CN-LGMV port on the main unit of the outdoor unit.
Visual display of key information about the operation of the air conditioner.
Graphic pressure indication and other parameters.
Monitoring the mode of operation of the internal blocks when the module is connected to the outer block.
Saving the data on the operation of the air conditioner as a file.
Report on work - the result of testing operation is formed into an HTML document.
Indication error number and support error search in the list of PDF document.
Mobile LGMV can be downloaded, for example, in Google Play as a product LG Electronics, Inc. As a tool for maintenance, troubleshooting for LG air conditioning systems. The LGMV mobile application uses a limited resource on the smartphone and processes the data in real time. Data monitoring can be complicated or data cannot be completely saved if the smartphone performance is low.
It is recommended to use a smartphone high performance. If system resources are not enough due to other included Internet applications, in addition to observation during data monitoring, malfunctions may occur. Monitoring and Saving Functions may not work in full. And the Bluetooth connection connection can be disabled. In addition, the application may be disconnected due to a lack of resources or an unforeseen error.
The data level may increase depending on the number of external and internal blocks. The data transmission distance via Bluetooth can be reduced until disabling the data transmission depending on weather or environmental condition (electromagnetic waves or obstacle), etc. It is recommended to use the Bluetooth module for a short distance.
If the LG air conditioner does not work - this is to us!
If the MDV air conditioner diagnostics is required - this is to us!
E0 | Error EEPROM. |
E1 | Error on the temperature sensors of the indoor unit 1 |
E2. | Error on the temperature sensors of the indoor unit 2 |
E3. | Error on the temperature sensors of the indoor unit 3 |
E4. | Error on the outdoor temperature sensors |
E5 | High or low power supply protection |
E6 | Error on the temperature sensors of the indoor unit 4 |
E7. | No connection between control and inverter boards |
P0. | Compressor overheating protection |
P1 | Protection in high pressure - only for M4OCI |
P2. | Protection in low pressure - only for M4OCI |
P3. | Protection against increased compressor current |
P4 | Worked the inverter module protection |
P5 | Low Outdoor Air Protection -7 ° C |
P6 | High condensation protection |
If the MDV air conditioner does not work - this is to us!
If the air conditioner Mitsubishi Electric is not working - this is to us!
If the Mitsubishi Heavy air conditioner does not work - this is to us!
If WISNOW air conditioner does not work, this is to us!
If the Polaris air conditioner does not work - this is to us!
Description of faults that are displayed on the Sanyo W-Eco Multi System's external block board. Fairly for SPW-CR1503GDYH8 models, SPW-CR1903GDYH8, SPW-CR703GDCH8, SPW-CR903GDCH8, SPW-C1503GDYH8, SPW-C1903GDYH8, SPW-C703GDCH8, SPW-C903GDCH8.
If the Sanyo air conditioner does not work - this is to us!
For example, fault indication in Sharp air conditioners AY-A184E / AE-A184E models, AY-A24E / AE-A244E.
If the SHARP air conditioner does not work - this is to us!
The code | Fault |
00-0 | internal air temperature sensor error or internal unit board |
00-0D | radiator temperature sensor error or control board |
00-11 | faulty or fan motor |
00-12 | replacing management board |
01-04 | burned fuses on the board, the wrong interconnection, the board burned down |
01-05 | inverter error |
02-14 | inverter Overload |
02-16 | circuit between compressor windings |
02-17 | current sensor error |
02-18 | temperature sensor error, PC boards |
02-19 | tD Temperature Sensor Error, PC Board |
02-1A. | error fan external block - current overload, blocked, engine or fee burned |
02-1b. | condenzor temperature sensor is defective or fee |
02-1C. | the compressor did not start for 20 seconds. |
03-07 | lack of refrigerant, error inverter board |
03-1D. | faulty compressor |
03-1E. | tD suction sensor error, insufficient refrigerant |
03-1F. | does not work compressor due to supply voltage, refrigeration circuit overload |
03-08 | fault of a four-way valve |
If the Toshiba air conditioner does not work - this is to us!
Works performed during diagnostics correspond to the work done at. The only difference is that during the diagnostics, all the basic parameters of the equipment are checked and recorded, and service The identified deviations from the norm are eliminated.
During the diagnosis of air conditioner, firstly, an external examination on the absence of mechanical damage is carried out. Not only cabinet, but also hydraulic and electrical parts of the equipment are examined. In addition, the reliability of fastenings of external and internal blocks is checked. As well as the quality of the clamps of all contact compounds of electrical equipment. Before turning on the equipment, you must view the condition of air filters. They should be not only clean, but without damage. After inspection, as a rule, it is turned on to "Cooling" mode. Use the control panel to test the system.
During the functional verification, the indication of the air conditioner modes is estimated, as well as the operation of the output blinds with a mechanical drive. One of the indirect indicators of the efficiency of the system is to control the temperature of dry air at the entrance and outlet of the evaporator. Using the pressure gauges, the average absorption / discharge pressure is performed (with free access to the outer block). Of course, the verification of the tightness of the connection of the internal and external blocks is obligatory. In addition, you need to make sure that there are no leaks in drainage system air conditioner.
On the nature of the malfunction, the specialist can be judged by the "behavior" of the air conditioner. For example, if the air conditioner is turned on and immediately turned off, after which the error message is displayed - most likely, the case in the sensors (fault sensors of air temperature or evaporator).
If the air conditioner turns on, it works 15-20 seconds, and then turns off - most likely, the fan motor of the internal unit is faulty (the speed of rotation is below the specified revolutions per minute).
If the air conditioner does not turn on at all and at the same time flashes (or not burn) all LEDs - most likely, there was failure pCB Control.
Simultaneous blinking of all air conditioning lamps, as a rule, only means the control board of control installations. Most likely, this is caused by non-compliance with the guests of network parameters, for example, due to a voltage jump in the network. Eliminate this fault is easy - just perform reprogramming the main control board. Since information about codes is provided only to authorized service centers, in this case it is necessary to contact our specialists.
If your air conditioner does not work, first of all, make sure that the air conditioner is securely connected to the outlet. Check the protection machine or fuse on the supply line, if necessary, restart the machine or replace the fuse. Read the user manual again and make sure that all modes are installed correctly.
Having done it yourself, you will save your money. Since in many cases you have caused by the engineer, having done what you can easily do yourself will require payment for a false challenge.
If these actions did not help, then contact the trade organization you can find the air conditioner. Or contact the air conditioner manufacturer's authorized service center. Of course, this is the best, speedy and reliable way to return the performance of your air conditioner. Information on how to contact them should give you a trade organization to sell the air conditioner. This information is available not only in the warranty card, but also on the manufacturer's website in the relevant regional section.
To facilitate the diagnosis in modern air conditioners there is a so-called test mode. Compared to the operating mode, the air conditioner is included in the cooling mode and does not respond to the testimony of sensors and air temperature. That is, in test mode, the air conditioner will function as much as it is necessary for the service engineer to explore the operation of the system blocks. After turning off the test mode, the air conditioner will return to normal operation.
SAMSUNG air conditioners also provide test mode. To enter the check mode, you must click on the internal block, the on / off button and hold it for five seconds. In this case, the temperature indicator displays the installed software settings option with the second interval, for example, 0B0000-1730F8: 0B00001730F80B (only for models with temperature indicator).
In the course of testing the operation of the air conditioner, the cooling mode is turned on with the following limitations:
- the compressor is forcibly working in cooling mode without turning on / off according to the installed internal temperature, without the thawing mode;
- the blade, the air flow guide up / down - to the rotation mode up-down;
- The inner fan rotates at high speed.