House, design, repair, decor. Yard and garden. Do it yourself

House, design, repair, decor. Yard and garden. Do it yourself

» Instructions for the operation of the Rinnai boiler. Rinnai gas boilers

Instructions for the operation of the Rinnai boiler. Rinnai gas boilers

For reliable home hot water And the heat must be installed special equipment. In each case, a specific model should be selected by affecting performance. The optimal choice is the gas boiler brand Rinnai. It is easy to install, special skills for installation is not required.

Boilers manufactured by Rinnai function on various gas. It can be natural or liquefied. Heat generated by burning fuel through the burners of a special design, with their operation, a minimum amount of nitrogen oxide is formed. However, despite the outstanding specifications Rinnai gas wall boilers, they are pretty simple. The housing is made of high strength steel. It is covered with powder paint. The most important elements of gas boilers are protected from atmospheric influences using foam foam. All models without exception are equipped with a smooth automatic flame control system.

Rinnai products are beneficial from similar devices of other manufacturers with some important features. First of all, it is the economy of boilers - the automation system regulates the temperature of the flame (gas savings is as much as 14%). Also Rinnai eco-friendly - the number of harmful substances emitted into the atmosphere is very small. There is an error diagnostic system, information about which is displayed graphically or a beep. Despite the large number of advantages and excellent performance, prices for boilers from Rinnai is small.

Varieties and modifications

The manufacturer has released 4 series: RMF, EMF, GMF, SMF. Each is intended for operation in concrete conditions. For example, Gas Japanese rinnai RMF boilers are able to heat the room with an area of \u200b\u200b180-420 m2. The main features include:

  • the ability to program heating a week ahead;
  • before starting work, the coolant is subjected to preheating;
  • there is a remote control.


RMF Series Rinnai is equipped with 2 types of consoles. This is Standart and Deluxe. Standard programms a gas boiler for 12 hours ahead. Deluxe modifications are submitted to the memory of as many as 5 modes with the calculation of 24 hours.

Rinnai also has a special series - wall double-circuit boilers EMF. All of them are used for the heating of rooms with an area of \u200b\u200b110-410 m2, which allows them to be used for heating even very large buildings, for example - multi-storey cottages. This series of boilers is characterized by a unique design of the burner, which makes the formation of toxic substances in the gas burning process is minimal. Also, Rinnai EMF is safe to operate. There are automatic gas shutdown systems, electricity. There is a voltage stabilizer.

GMF marking boilers have even on the background of similar devices with excellent operational parameters. They are able to heat the area of \u200b\u200b100-400 m2. This is enough for most private houses. GMF series has the following features:

  • freezing protection (damage gas boiler due to low temperatures excluded);
  • ignition system from electrical spark;
  • self-diagnosis - allows the user to quickly detect a malfunction and eliminate its cause;
  • some modifications are optionally equipped with circulating pump.

Boilers are installed in places where water pressure is not very large. That is why they are often exploited in the villages and dachas. It should be noted the maintainability of all models: spare parts of the gas boiler heating Rinnai RB-GMF (and other similar) is easy to find in specialized stores, and independently eliminate malfunctions of various kinds will not be difficult.

The SMF series has many features. The most important is the possibility from natural gas. Go to liquefied by replacing the nozzles in the boiler. The amount of CO2 allocated in the process of fuel combustion is not more than 5.72%. The equipment of this series of Rinnai is intended for heat heating from 100 m2. Thanks to the automatic regulation system, the operation of the boilers is carried out even at low gas pressure.

Cost and description

NameMaximum power, kWHeated area, m2Price, rubleIn × sh × g, mmWeight, kg
GMF RB-36741,9 400 55 500 640 × 440 × 24029,5
GMF RB-10612 186 24 800 660 × 440 × 26624,5
GMF RB-36642 419 43 500 600 × 440 × 24029,5
DMF-206.23 233 39 000 600 × 440 × 26629
DMF-306.34,9 349 51 000 600 × 440 × 26625,5
EMF-207.23 230 41 500 660 × 440 × 24029
EMF-267.29,1 218 43 200 600 × 440 × 24029
EMF-167.18,6 140 36 000 600 × 440 × 24024,5
EMF-257.29,1 218 43 000 600 × 440 × 26629
DMF-206.23,3 233 42 000 600 × 440 × 26629
RMF RB-36741,9 419 46 725 600 × 440 × 25031,5
RMF RB-20723,3 233 44 030 600 × 440 × 25027,5
RMF RB-16718,6 186 30 688 600 × 440 × 25026,5
RMF RB-25729,1 291 37 145 600 × 440 × 24029,1


Pros and cons

The advantages of all rinnai boilers include:

  • small dimensions and low weight;
  • economy;
  • presentable appearance;
  • automation;
  • ease of design, maintainability;
  • reliability and durability.

Rinnai equipment has its own "independence": it is enough to program only 1 time. It also implies minimal service. For example, the RINNAI RB-106 GMF gas heating boiler is equipped with a special smoke. This minimizes the formation of soot on the walls of the chimney. These aggregates have some disadvantages. The temperature adjustment step is relatively large that it often does not allow to set the necessary value. Especially if high accuracy is required. But, despite some minuses, boilers from Rinnai will become an excellent acquisition for a private house.

Opinions of buyers

According to numerous reviews of the gas boilers of heating Rinnai, due to the universality of the design, they are capable of working with low pressure - up to 0.03 MPa. Even if this parameter is significantly lower, the automation will support the temperature of the desired value. Which reduces the likelihood of fire to a minimum.

"Bought the Rinnai gas boiler, the GMF RB-106 model. Attracted a nice appearance and compact size. Installation performed independently, without assistance - fasteners are made extremely successful. After installation, it started immediately, without any problems. Works year without complaints. By cons by only a small vibration. "

Konstantin, St. Petersburg.

"For heating two-storey house Acquired a boiler from Rinnai, DMG series with a circulation pump. The coolant is just well - the heating batteries are hot not only on ground floors, but also in the basement. The disadvantages include a certain amount of condensate - solved this problem with an increase in the temperature of gas burning. In general, work is satisfied. "

Anton, Moscow.

"The GMF RB-106 (production of Rinnai) was acquired on the advice of a familiar Gazovik. Attracted value for money. Installation is carried out at the expense of the store. On the very first day, there was a flow at the entrance of the heating circuit - the installation defect was eliminated in 15 minutes. The boiler is relatively quiet, convenient to control thanks to the consisting of the console. "

Dmitry Ivanov, Kazan.

"1.5 years ago I bought a gas wall boiler manufactured by the Japanese company Rinnai. I liked the location of the chimney - behind the case. No need to remove the pipe through the roof. In the process of installation, some difficulties arose (the standard fastener did not fit), but this problem was allowed quite quickly with welding. Programming is very simple. Gas equipment from the company Rinnai copes with its work for all 100%. "

Vasily, Volgograd.

"The gas boiler set 6 years ago, everything was more or less normal, broke several times, but quickly eliminated breakdowns. They did not independently repaired, always appealed to the service center. This year and from under the cover, and from the tubes from everyone dripping, several times turned to specialists, various masters came and everyone had different versions about why flows. Renate, and after a week the situation is repeated. I'm afraid, this year will have to put a new one. "

Natalia, Moscow.

"And I was not lucky with Rinnah. A year later, the primary copper heat exchanger was covered, the entire liquid flowed into the floor, well at least turns off. For the repair gave 20,000 rubles. Do not please the temperature difference - it is hot, then cool, gas from Gazgolder. "

Evgeny, Tula.

"Installed the boiler Rinnai 42 kW in November 2005 for heating a two-storey house with an area of \u200b\u200b297 m2. For 11 years I have 56,000 m2 gas, plus gas-burner in the bath. The grid on the hot water supply was hampered twice because of the rigid water. A little noisy (at night), there is no other complaints. In my advice, this boiler was established by a man 10 - everyone is satisfied with excellent efficiency and quality. "

Victor, Novgorod.

Any lucky owner of one's own country housing or wishing to build a house should solve the problem of heating his dwelling. Since the base of the heating system is a heating boiler, it should be started from its choice. Here we will look at the Rinnai wall-mounted gas boiler, as the most popular and economical of the numerous list of equipment for heating, for private houses and large social or industrial premises.

The list of such devices for heating today is quite large, the market offers heating units, various manufacturers firms that differ in power, functionality and type of fuel used for heating. Choose a boiler, follows from your needs, the area of \u200b\u200bheated housing and air temperature behind the walls of the house. Heating systems based on autonomous heating units will provide warmth of your housing during the cold season, in the most severe climatic conditions.

Fig. one

Choosing a boiler

One of the important differences in the heating boilers consists of used fuel:

  • Solid fuel devices require firewood, pellets or coal;
  • Liquid fuel work on diesel;
  • Gas - respectively on natural or liquefied gas;
  • Electric use electricity.

Depending on the availability and efficiency of fuel, you should stop your choice on the appropriate heating unit. Of course, the first requirement is the presence of an elected highway with natural gas. And, since natural gas is still the most inexpensive fuel, gas aggregates are most practical and cost-effective in currently.

The great advantage of gas heating systems is work on natural gas, which allows you to not have the various difficulties with the purchase and delivery of fuel, uncomplication in the operation and maintenance of equipment. And from electrical heating systems, gas installations are distinguished by the low cost of fuel.

In addition, it is necessary to determine the required power of the boiler, which is indicated in the instructions. Depending on the volumes and areas of heated premises, the corresponding model of the heating unit is selected.

Rinnai equipment

The Japanese company Rinnai (Rinnai), which produces heating equipment, is known all over the world and has established itself as a reliable manufacturer of economical and reliable, not requiring repair, equipment. Gas boilers RINNAIKOMPacts and very convenient in operation.

They have an elegant design that does not spoil the interior of the premises, and functionally satisfy all the needs for heating and hot water supply small houses. Such devices are easily placed in small rooms and cope with the creation of a warm atmosphere and comfort in the house.


Fig. 2.

The main difference between Rinnai heating equipment is automatic adjustment of the gas-air mixture. Control and adjustment of the combustion process is based on advanced technologies using touch sensors and electronic processors. Automation allows wall gas boilers RINNAI DMF series, GMF and SMF to work steadily even with a critical low gas pressure.

Such an important feature is fundamental for Russian conditions. Do not rarely have a gas supply interruption. It also affects efficiency, since the change in the volume of incoming gas controlled by the sensors changes the boiler power. Thereby, gas boilers Rinnai is perfectly suitable for domestic climate and consumer.

In general, the positive aspects of the Rinnai wall gas boilers describe the following characteristics that are listed in the instructions:

  • Protection of the electronic control unit;
  • Normal functioning under reduced water pressure;
  • Compact sizes that allow you to accommodate the unit in little room;
  • Environmental Safety;
  • Economic efficiency;
  • Electronic control of the level of flame and the combustion process;
  • Elegant design;
  • Adaptation to Russian conditions, reliability that does not require repair.

Rinnai gas boilers received tremendous popularity in Russia, also because they combine functionality and aesthetic quality, do not require continuous repair. In order for the products of Rinnai to find their consumer in Russia, the company has a number of representative offices designed not only to increase the implementation of equipment, but also to implement technical and information support.

Now the acquisition of wall gas boilers Rinnai becomes convenient and favorable decision To create heat in your home. All equipment is described in detail in the attached instructions.

Hot water supply


Fig. 3.

Rinnai supplies to Russia, mainly devices allowing hot water for household needs. These are so-called dual-circuit units.

Maybe of course, in the case of using a single-circuit boiler to equip his external boiler, but taking into account mounting workThis will come out somewhat more expensive than the acquisition of Rinnai wall gas boiler with two contours.

Choosing a similar model, pay attention to the specifications, in terms of the amount of water heated per minute. The need for hot water can be calculated on the basis of the presence of plumbing in the house at the rate of the calculation that the washbasin consumes up to 5 liters hot water per minute, and more than 7 shower. By summing up all available washbasins, it is possible to calculate the maximum load on the heating device.

The lineup

Fig. four Installation on the wall
Equipment "Rinnai"

Special demand in Russia enjoy the leading types of aggregates -Rinnai DMF, Rinnai RB 106GMFI Rinnai Rb 366 GMF. Interest in them is explained by technical characteristics and reliability, the repair is practically not required. Compact dimensions, however, allow you to place inside all the necessary electronics and automation for uninterrupted operation.

An important advantage of Rinnai gas boilers is the minimum level of nitrogen and carbon monoxide gas. The presence of a digital control panel provides convenience and simplicity of the aggregate.

The system contains the temperature sensors of the coolant and heated air, this automatically maintains comfort in heated rooms under all weather conditions. The optimal temperature in the house provides, also, ultra-precisely controlling the flame and the combustion process, which also allows economically to spend gas.

ModelNAI RB-166 DMF

Wall-mounted double-circuit boiler having a closed combustion chamber. Great for heating and serving hot water in residential premises with an area of \u200b\u200bup to 185 sq.m. It can be mounted even in the kitchen. Power - 4.6-18.5 kW. Products combustion and air supply is forced through coaxial chimney. KPD - 93-96.9%.

Specifications:

  • Natural, liquefied gas;
  • Accommodation - wall-mounted;
  • The presence of a closed combustion chamber;
  • Productivity on DHW, heating to 25 degrees - 12 l / min.
  • Pressure in the heating circuit 3 bar;
  • The volume of the tank is 8.5 liters;
  • Automatic system malfunction diagnostics;
  • Consumption of the main gas at maximum power - 1.8 m3 / h;
  • Dimensions 600 * 440 * 266 mm;
  • Weight - 28 kg.

RINNAI RB-307 RMF Series

The sale of sales can be called the wall gas model KotlainnaIRB-307RMF. Its power is 34.9 kW. This device copes with heating and hot water supply of rooms with an area of \u200b\u200bup to 350kv.

  • Dimensions, mm - 600x440x250;
  • DHB performance at T \u003d 40 ° C, l / min - 15.0;
  • Expansion tank - 8.5 liters;
  • Weight - 29.5 kg;
  • Accommodation is wall.

The boiler, like many other models, has an emergency protection, gas supply is stopped by automatic, the boiler turns off and the start should be done manually after repair and correcting the fault. Management can be made using three varieties of remote controls: "Standard", "Deluxe" and "WiFi".

The last two, if desired, can be purchased additionally. The consoles are equipped with a well-readable LCD display with an intuitive graphical interface and detailed instructions.

RNNAI RB-367 RMF Series

Wall-mounted multifunctional double gas boilerrinnairb-367RMF refers to a new line of high-tech heating equipment. It has the necessary security certificates, resolved by Rostechnadzor to use in Russia, which is indicated in the instructions.

This unit is able to maintain heat and provide hot water supply to 430 sq.m. The two-round wall-mounted boiler "Rinnai" has modern design And it is organically suitable for any interior of an apartment or at home. Due to the compact housing and the closed combustion chamber, it is well mounted on the walls of the room with natural air circulation.

  • Power, kW - 41.8;
  • Size, mm -600x440x250;
  • Performance for DHW at T \u003d 40 ° C, l / min. - 15.0;
  • Accommodation - wall-mounted;
  • Weight, kg - 31.6;
  • Type of burner modulation;
  • Automatic malfunction diagnostic system;

Rinnai RB-206DMF

Wall double-circuit boiler Rinnairb-206 DMF, equipped with an accelerated flowing water heater. This model is equipped with a silent modulation fan burner closed type. The automation allows you to smoothly adjust the combustion of gas depending on its pressure. Therefore, the unit 206 DMF can successfully function at low gas pressure, while maintaining the boiler power from 25 to 100%.

The microprocessor controls the composition of the fuel and air mixture, allowing you to save fuel consumption up to 20%. Equipment has 13 patents. Due to full combustion Gas has a high efficiency - from 93 to 97.5%

  • Power, kW - 23.4;
  • Heated area, m2 - 233;
  • dimensions, mm - 600x440x266;
  • Hot water capacity, at t \u003d 40 ° C l / min - 10.3
  • Automatic malfunction diagnostic system;
  • Accommodation is wall.

Conclusion

For the convenience of consumers, buy Japanese Rinnai gas boilers in Russia is possible not only in Moscow, where there is a head office of the company's representation, but also in other major Russian cities, as well as on the website of the online store.

Rinnai equipment is reliable and safer for the environment, efficient and economical. Gas equipment warranty - 2 years. Choosing the products of Rinnai, you not only provide your home with warmth, but also make a profitable acquisition, embodied in quality and modern technologies.


Rinnai is mainly associated with the manufacture of high-quality and functional air conditioners in the domestic consumer, but it produces not only this climate technique. Relatively recently, heating equipment made by the Japanese concern appeared in the Russian Federation.

Judging by consumer reviews and operating experience, Japanese gas boilers Rinnai, like all the rest of the brand, are distinguished by reliability, functionality, thoughtful design and control system.

Device of heating boilers Rinnai

The main philosophy of the company Rinnai is the following theses:


All of these three points were reflected in the line of heating equipment of the company. The following modifications are presented:

  • RINNAI RMF series - in modification features equipment with the ability to connect to the system " smart House" The main difference model Row is an active gas consumption saving. When the DHW is turned on, the burner can operate in three modes, providing the necessary heating.
    Additionally, a high-speed heating unit is provided, allowing hot water immediately after opening the crane. Another innovation that has hinged heating gas double-circuit boilers RINNAI RMF is that the heating of the coolant is controlled by two microprocessor, adjusting each other's work. It is possible to set the daily mode of operation gas equipment, taking into account the characteristics and preferences of the consumer.
    Room thermostats connected to the control unit help even more reduce gas consumption for heating.
  • Rinnai EMF - Economical gas consumption is achieved due to proportional flame adjustment, with the aim of low nitrogen oxide isolated, which makes it possible to prevent heat loss. Traditionally, the ability to support the temperature of warm water is used. The 3-way valve provides stable heating, regardless of the number of users and pressure.
    An individual wall-mounted double-circuit gas boiler Rinnai EMF has the provided simple connection feature of both the main and an additional heating system (warm floor).
  • Two-integral gas condensation attachments heating boilers Rinnai CMF. Equipped with an advanced control system for automatic control of the volume of the flame and water heating to a certain temperature. The control unit helps to choose the optimal mode of the boiler, for the next 24 hours to avoid fuel recalculation.
    Household condensate wall double-circuit gas boilers Heating Rinnai, CMF series, remove combustion products through coaxial chimney, which speeds up the installation process and makes it possible to install stations in multi-storey buildings.

All models of Rinnai boilers are energy-dependent and when the electricity is disconnected, stop working. Microprocessors used in automation are sensitive to voltage drops on the network. For stable operation, you will need to install the uninterruptible power supply, generator or battery.

Installing and Connecting Rinnai Boiler

Installation and connecting the finished heating system to the rinna boiler requires a certain qualification. Consumer reviews show that the main problems and difficulties arising during operation are largely dependent on errors made during installation.

The manufacturer indicates the procedure for connecting and basic requirements for installation:

Increased liquefied gas consumption often occurs due to incorrect settings. To verify compliance with the operating conditions and set the necessary questions, you can use the QR code and with it through the mobile device to go to the manufacturer's official website.

Operation of boilers Rinnai

For a private house or apartment, Rinnai boilers are practically the ideal option. Almost all settings are performed automatically. The control unit has a display that reflects all operating performance: pressure in the expansion tank, heating temperature, system volume, operation mode, etc.

With low gas pressure, a warning is also fed to the monitor, and the station operation is automatically translated into the economy mode.

The remote control of the boiler can be carried out using a remote controller installed in one of the rooms or remote control. Several room temperature sensors can be connected to the controller.

Periodically, the adjustment of the gas valve may be required. This will allow you to establish the minimum consumption of balloon or main gas.

After troubleshooting in the operation of the electricity disconnection, all settings remain in the processor memory and are installed automatically.

Choose a wall gas boiler Rinnai

Almost all modifications of boilers have the same specifications and performance. The difference mainly consists in the degree of automation of the process of managing the equipment of the equipment, as well as the presence of systems that provide environmentally friendly and economical burning of gas.

In all models there is a secondary heat exchanger, which ensures rapid water heating, but in the RMF series, the consumer gets hot water instantly.

Rinnai boilers are distinguished by reliability and ease of operation. Good decision For those who primarily appreciate comfort and unlimited in tangible means.

Of all modern Systems heating gas double-circuit boilers - the most optimal option For service at home. If you judge user reviews, high-quality equipment with high performance offers Japanese concern Rinnai. Aggregates are characterized by functionality, reliability, original design, accurate control system. When the network failures, a low pressure pressure on the sensors is received by a warning, automatically translates into economical mode, which avoids faults.

Almost all types of gas boilers have the same specifications. The difference is the complexity of the adjustment systems, equipment capacity. Rinnai aggregates are designed for heating and supplying hot water in residential and production rooms. We work on natural gas (centralized highway) and liquefied fuel. Devices received certificates, comply with safety rules.

Rinnai appliances installation is carried out in any room, a special compartment is required. Gas boilers can be placed on the square with natural ventilation. The accommodation of the coaxial pipe allows you to abandon the use of a conventional chimney. In mandatory, Rinnai boilers must have grounding. It is not recommended to include on the territory with high humidity. Installation of a boiler operating on a liquefied fuel is prohibited in the premises below the soil level, without proper sealing. When malfunction cannot be repaired independently, you need to contact the Rinnai service.

Product description

According to consumers' reviews, the following models are considered the most popular:

Wall gas boilers are considered the most economical in terms of resource consumption. They can be connected along a chain, providing heat and hot water, both in small apartments and in large homes. Rinnai power in the heating mode of rooms is 11.6-42 kW with efficiency of 96%. The area of \u200b\u200bthe serviced space is 30-120 m2, the gas consumption is 0.3-1.15 m3 / hour, GVS -12 l / min. Volume expansion tank - 8.5 liters. If you need to work on liquefied fuel, nooks are required.

The Rinnai design includes a modulation burner of a fan type with an automatic resource consumption function in proportion to pressure. Such a feature is aimed at saving within 20%, provides a large operational period of heat exchanger and gas adjustment system double-circuit boiler. As a result of complete combustion, there is a low level of toxic waste, which does not allow inundations of nagar and soot on the nozzles. The series includes models: RB-107, 167, 207, 257, 307, 367.

Advanced version of wall gas dual-circuit boilers from Rinnai manufacturer. With elevated functionality, the equipment is less than noise. The console is equipped with a color display, there is a voice control mode, weather-dependent sensors. When heating, you can reduce the power of the device by 20%. For achievement optimal temperature Water is used adjusting node. Thanks to the periodic heating, the instant gVS feed. The Rinnai device operates with a minimum pressure of 2.5 l / min, disconnected at a pressure in pipes of 1.5 l / min. The standard bundle includes a remote, which, according to user reviews, simplifies the coordination of all systems.

Gas boilers S. closed chamber Combustion Rinnai has a capacity of 19-42 kW, the area is heated in size 190-420 m2. Efficiency is 90%, the volume of the expansion - the tank is 8 liters. The device is equipped with an ECO program (environmental mode). It has two additional sensors: control of protection against freezing and coolant temperature. The series includes models: RB-107, 167, 207, 257, 307, 367.

Rinnai gas boilers function on the main and liquefied fuel, subject to the shift of the nozzles. The main advantage of this subgroup is absolute ecology, which is due to the minimum emissions into the atmosphere of toxic waste. The automation unit is three-level, adjustment of the flame burner and heating of the coolant is determined depending on the season and climate. Error diagnostics are displayed on the monitor in text and digital code. The adjustment of the fan operation protects from the lack of air for purge.

The power of the wall gas boiler is 12-42 kW, heated area - 120-420 m2. The minimum consumption of DHW is 2.7 l / min, centralized resource - 1.1-4.2, liquefied - 1-3.5 m3 / hour. The volume of the expansion tank - 8.5l, the maximum temperature of the coolant - 85, DHW - 60 ° C. To remove combustion products, coaxial chimney is used. Model series: RB-166, 206, 256, 306, 366.

Gas boilers produced Rinnai are designed to maintain premises from 100 to 400 m2. Equipped with two heat exchangers, the first is made of copper, the second is characterized by speed and up to 14 l / min. In the combustion chamber, smooth regulation of the fuel and air mixture, proportional to the volume of the gas, occurs. This is achieved due to the built-in burner with turbocharging. Optimal functionality does not depend on weather conditions. The release of toxic substances is minimized that it does not allow the formation of soot and scale.

The capacity of the boiler is 18-42 kW under the efficiency of 90%. Minimum water consumption - 2.7 l / min. The temperature range for heating is 40-80 ° C, for hot water supply - 35-60 ° C. The device has a pump with electronic adjustment. The microprocessor constantly analyzes sensor readings and sends information to working nodes. Air fence forced, from the street. The series includes models: RB-166, 206, 256, 306, 366.

What do users say?

To purchase a Japanese housing care boiler, buyers evaluate its specifications. Make sure the quality and functionality of the aggregates can be with the help of guest reviews using devices for a long time:

"For our cottage, a boiler was chosen from the manufacturer Rinnai, the RMF RB-367 brand. It heats the room, serves hot water in the required quantities. There is practically no release of toxic smoke when gas processing, thanks to an improved environmental system of work. The unit can be controlled remotely, it connects even to a mobile phone using a special application, which is very convenient. For 3 years of operation, it never required the repair, which indicates the high quality of Rinnai products. "

Anna, Novosibirsk.

"The boilers from the company Rinnai are considered one of the best and upgraded, so I decided to buy an EMF RB-107 series for the apartment. It has an acceptable price, excellent specifications. Despite the fact that it is heating the premises and serves hot water, the savings are felt significant. Due to the set of sensors, you can adjust the work even at low pressure. Automation protects equipment from freezing and overheating. For 5 years of operation, it was necessary to contact the service office for repair. The incorrect encoding of the control system led to a failure. After debugging, this Rinnai model functions perfectly. "

Sergey, St. Petersburg.

"Rinnai decided to buy equipment, taking advantage of positive feedback reviews. They installed the boiler in the house three years ago, we purchased last winter. Excellent design, uninterrupted functioning, thin adjustment system - small list of advantages of the unit. It copes well with the heating of the building and the feed of hot water. Corrects temperature depending on climatic conditions. With proper handling and maintenance of problems with the work of Rinnai technology, there is no. We have a brand GMF RB-366. "

Valentina, Moscow.

"We use the boiler from the Japanese manufacturer Rinnai for two years. Installed the SMF RB-266 model for heating and hot water. The house is always warm in winter, and the device independently adjusts the temperature, depending on weather conditions, so it is too hot or cold. DHW is applied almost instantly, thanks to periodic heating. You can control remotely, as there is a remote, it is also convenient to set the program, in the event of a long lack of family members. For us, the advantage is the fact that there is no need to mount the traditional chimney, cost coaxial pipe. In this case, the difference is not felt. "

Mark, Almaty.

Cost Rinnai.

Choosing a suitable model of the Rinnai gas column, the buyer pays attention to the characteristics of the equipment: power, performance. Acting electronic controlThe price depends on all factors, including the adjustment system and remote remotes:

Rinnai gas boilers - high-quality equipment with great performance for residential and industrial premises. When changing the nozzles, it is possible to use liquefied fuel, except the main resource, which is relevant for owners country houses. The perfect management system allows you to adjust the modes and set programs. Repair and maintenance of boilers are made exclusively in service centers.

Japanese heating devices Rinnai has long received high marks from consumers all over the world due to their economy, which is achieved by the introduction of original technical solutions. These heating units differ significantly from analogous efficiency and minimal emissions of harmful substances into the environment.

Features

Rinnai is one of the most famous Japanese corporations producing high-level equipment affordable prices. She appeared back in 1920. In the process of producing their products, the Concern's specialists apply the most interesting copyright ideas and the latest technologyThat allows you to create the most productive and economical devices for heating systems.

Characteristic features of devices from the famous Japanese brand:

  • heat exchangers are made of high-quality copper;
  • high environmental parameters;
  • the ability to control the unit remotely from a mobile phone;
  • comfortable control panels;
  • compact dimensions;
  • efficient performance even with a reduced gas pressure level;
  • regulation of the combustion process of fuel;
  • increased efficiency;
  • silence and lack of vibration.

It should be noted that the price of Rinnai gas aggregates will be available to any medium inhabitant that favorably distinguishes data from the analogs produced by other well-known companies.

Any product from the Rinnai brand will be allocated by excellent functionality, 100% reliability, simplified control. If the power failure suddenly occurs or the level of fuel pressure drops, a warning will immediately receive a warning to the device sensor, and the device will automatically be translated into savings mode to avoid subsequent problems. Products from Rinnai can easily function in any type of gas - no matter, it will be or liquefied. The heat will be generated by burning gas through the burners having a special technical design, a small number of nitrogen oxide will be formed by their work.

At the same time, consumers should know that despite the fact that the Japanese aggregates have the most outstanding characteristics, their device and operation are quite simple. The body of the product is made of durable steel, which is covered with special powder paint. The main elements of the devices are protected from different exposure to filling from foam. All popular manufacturer models have a flame autorplification system.

All processes occurring in the instrument are under the control of electronic sensors. In these devices you will never see the soot due to the fact that the fuel in them will be burned without a residue. The new burner of the ventilation type itself will adjust the necessary proportions of air and gas, which will significantly increase the efficiency of a particular device even with a small level of fuel pressure.

Views and Series

To date, the manufacturer offers a choice of consumers 4 series of devices under the abbreviations "RMF" and "EMF", "GMF" and "SMF". Each of these series is intended for use in strictly defined conditions.

The products of the RMF series will be able to heat the space having an area of \u200b\u200b180 to 420 m2.

Their main characteristic features include:

  • the ability to program the launch of the desired temperature for the heating of the dwelling is 7 days ahead;
  • before the start of work, the coolant available in the product will be prehered, which, in turn, will accelerate the rate of warming up the premises;
  • the presence of remote control device.

The "RMF" series has a complete one of the 2 types (Standart option and Deluxe option) control panels. With the help of a standard console, you can program the operation of the unit at 12 o'clock in advance, which is extremely convenient. With the help of the Deluxe variant, it will be possible to get into the memory of the console already as 5 modes (with the calculation of the work for 24 hours ahead).

Rinnai produces a very specific series of "EMF" aggregates with two contours. All of them are suitable for heating spaces having dimensions from 110 to 410 m2, which will allow them to warm them up sufficiently large and even multi-storey buildings. This series of devices is complemented by a special type of burner, with which you can minimize emissions of poisoning components during the combustion process in the system. In addition, Rinnai EMF is completely safe when using daily use. They are built into fuel and electricity systems. There is a device that stabilizing the voltage.

Devices "GMF" are endowed with the most interesting operational characteristics. They can heat large squares - from 100 to 400 m2, which is quite suitable for private houses.

"GMF" series has such characteristic features as:

  • protection against freezing (which is why even because of a fairly low temperature, the boiler will not be damaged and will continue to work);
  • helicing system from electric spacing;
  • self-diagnostics - with its help, the user will independently be able to quickly find the breakdown and easily eliminate its cause;
  • certain models are complemented by the pump for circulation.

Boilers are mounted where the level of pressure of the coolant will not be very significant. For the reason, they are most often purchased for use in rural areas and in country villages. It should be noted that all models of the manufacturer are easy to repair if necessary. Spare parts for the product "Rinnai RB-GMF" and to him are easily located in specialized stores, and the consumer itself can eliminate the breakdown of the boiler without contacting the specialists.

The main advantage of this series is environmental purity due to the minimum emission to the atmosphere of poisonous waste. The automation unit here has 3 levels, the regulation of the flame and the heating level of the coolant can be determined depending on seasonality and climatic features. Diagnostics of all possible errors Lights on the screen in text and (or) as a digital code. Adjusting the fan operation will protect from the lack of oxygen for purge. The power of such an aggregate will be 12-42 kW. The most popular models from this series are RB-166, as well as 206 and 256, 306 and 366.

The SMF series has many interesting features. The most important of them can be considered the possibility from a natural gas without difficulty to switch to liquefied fuel, just replacing the nozzles in the device. The amount of CO2 obtained during fuel combustion is not more than 5.72%. The aggregates of this series are manufactured for heating spaces from 100 m2. Thanks to the authoring, the operation of products will be carried out even at a low level of fuel pressure.

The series boilers have 2 heat exchanger, one of them copper, the other - steel and quite workable, it guarantees heating the coolant to 14 liters per minute. In the combustion chamber, the fuel and air mixture is adjusted, which is proportional to the volume of the fuel used. This can be achieved thanks to a burner with a turbocharger. Functionality of products will not depend on climate. The emission of harmful substances is minimal, so you will not see any soot or traces of scale.

Using innovations when producing their aggregates, Rinnai concern also produces condensing products. The aggregates of this series have increased equalization rates by the number of carbon monoxide output. This is one of the features of fuel supply to the burner. A homogeneous mixing of fuel and oxygen is carried out, then they go together on the burner. Carbon monoxide will necessarily pass through the special holes in the heat exchanger, therefore, in this case, the carbon monoxide will also give its heat into the system.

The most sought-after models

RB-167EMF.

Convection device has a power of about 18.6 kW. It is compact in parameters, includes a chamber structure for combustion of a closed fuel. With the help of a special burner, the fluid in the coolant is heated to 85 degrees, and in the DHW circuit - up to 60 degrees. The performance of the 2nd circuit is up to 10-12 liters per minute. You can easily connect the "Warm floor" system to the product. In addition to the device included room type thermostat.

Positive points of use of the product:

  • the combustion system will extend the service life and will reduce the number of malicious emissions;
  • Contour adjustment according to the air temperature parameters in the room;
  • elevated efficiency - 93-94%;
  • excellent work even with significant fluctuations in the level of fuel pressure in trunk networks;
  • there is a pump for circulation, an 8 liter tank, a mud filter

Rinnai RB-327CMF

This unit is also condensing. Its main plus can be called high efficiency. Thermal power of the device reaches 35.5 kW, the highest heating area is 372 m2. The product is in a strictly decorated case on which you will not find the control panel - all controls will be located on the thermostat. You can also connect external control modules that work on the GSM channel to monitor work at a distance.

RB-167RMF.

The original unit is complemented by an control screen with a color screen. The device has a circuit with a closed fuel combustion chamber, which takes oxygen and from outside, and from the room.

Characteristic features of this model:

  • control at a distance using a mobile phone;
  • temperature control program in DHW;
  • weather-dependent automatic system;
  • the ability to regulate the contour for heating by temperature in all rooms.
  • self-diagnosis;
  • connecting a voice control thermostat.

Rinnai engineers supplemented the boiler with a combustion system, which is characterized by 100% burning fuel with a significant decrease in the amount of poisoning substances emitted into the atmosphere. The first heat exchanger is made of copper, the second - steel. On board the unit there is a strapping needed to operate - from the tank to the security system.

User's manual

For its own dwelling or ordinary apartment, Rinnai product can be considered just an ideal option, so the choice of domestic consumers still stop on them. Almost all settings are made in authors. The control unit has a screen on which you can find all the necessary indicators: the pressure level in the tank, the heating temperature, the functioning mode of a specific instrument.

With a reduced fuel pressure level, a special signal also goes to the display, and the operation of the aggregate automatically goes into saving mode.

You can remotely control the product using a portable controllerwhich is usually installed in any of the housing premises, or the control occurs with the remote control. A number of sensors measuring room temperature are connected to the controller.

From time to time it may be necessary to regulate the gas valve. This will help reduce gas costs in cylinders or trunk fuel.

After failures in the work of the electricity disconnection, all settings are saved in the processor memory, and after troubleshooting is automatically restored.

Repairs

The intellectual control of Japanese boilers allows you to display information about the user failure or malfunction on the display as a specific code.

Rinnai boiler can be ground immediately after starting work due to errors "11" - This is a product signal that the system does not pass fuel. Perhaps the sensor failed controlling the flame level does not work solenoid valve, on which the health of the gas valve depends, or simply burned down the board. This can also pick up the pressure reducer of the pressure level and the shortage of the fuel level required for the start of the system.

Code "12"appears on the display when placing flames more than 15-20 times. This happens due to the reduced level of fuel pressure in the system or due to the presence of garbage on the burner itself.

Code "14" Indicates that in the power supply control of the boiler, there are certain breakdowns that can be solved on their own.

Code "15"indicates that the coolant circulation course was broken. The product circulation pump is in it in a single instance. If in hot water or heating mode, this pump is not driven by water, then this will be the main reason for the failure. It is necessary to open the plug of the pump itself and view whether the operation of the rotor is or not. To adjust it, you can carefully push the screwdriver to start moving. You can also clean the filter-mud for the liquid.

Error "18"- This is the transition to earth closure. Most often occurs when a specific voltage is shifted (more than 5 V) in the line of an electric module. To eliminate this error, it is necessary to check the voltage level between the 3rd pin CN3 of the electric module and the line during the ground. It will be necessary to make sure the cable coating.

Error "43"- Critically reduced coolant temperature and pressure reduction almost to 0. You can try to power the product through the water tap until the required level of pressure is obtained and try to turn on the boiler.

Error "16" - No coolant. To eliminate this malfunction, check the availability of water in the system.

Error "99" - the impossibility of removal of generated gases. Most often this happens because of the exhaust fan breakdown. To eliminate this problem, it is best to immediately contact the service. There, experts will clean the fan itself, as well as the entire heat exchanger.

Gas aggregates of the Rinnai brand - high quality equipment with excellent performance for residential and industrial buildings. When replacing the injectors, liquefied gas can be used, which is very popular with many owners of country houses, next to which there is no main gas. The original control system will allow you to adjust the required modes and set required programs For counting seconds. Reviews of boiler owners are quite positive. Repair I. service maintenance It is best to produce products only in service centers, you can sell spare parts there.

For the features and characteristics of Rinnai boilers, see the video below.