» The ferroli boiler does not turn on. Error codes gas boiler Ferroli - main malfunctions ways to eliminate them

The ferroli boiler does not turn on. Error codes gas boiler Ferroli - main malfunctions ways to eliminate them

During the operation of any equipment, it is important to know about possible malfunctions, ways of their manifestation. Thanks to the use of high-tech equipment, it is quite easy to detect this or that deviation. The sensors will be informed about this. No matter how reliable the Ferolli boiler is, errors can occur. In such situations, it is important to eliminate the cause as soon as possible.

Description

One of the most popular models of the company is the Ferolli Pegasus boiler. Error and error messages are displayed both on the display of the unit itself and on the remote control. Errors are displayed as code. With the help of sensors, it is much easier and more convenient to determine the place where the malfunctions have occurred.

Types of errors in the Ferroli boiler

At its core, all errors in the Ferolli boiler and malfunctions are divided into two types:

  • critical;
  • non-critical.

As a result of the first type of errors in the Ferroli boiler, a complete blocking of work occurs. To restore operability, you need to eliminate the cause of the operation. After that, the system is rebooted in manual or automatic mode. This is done using a special "reset" button.

Restarting will not work if you press the button right away. Any serious error will take at least 30 seconds. Only after such a pause (denoted by the D4 code) can a restart be carried out. This is one of the security points of the device.

Critical errors of the Ferolli boiler, requiring a restart, start with the letter "A", followed by the code number.

If the system detects any minor flaws in its work, then it is automatically locked and unlocked. And only in the case of repeated repetition of some kind of malfunction, electronics can require human participation. The code for such errors begins with the letter "F".

Pause

In addition to the Ferroli boiler error codes "A" and "F", there is "D". They represent different intervals. It is not some kind of malfunction.

For example, the “D3” code can be observed between attempts to ignite the flame. This code is quite common. It denotes an interval of 50 seconds.

Ferroli boiler error category "A"

"A01" is highlighted when the system fails to ignite or hold. This code can be caused by the following factors.

  • Defective electrode.
  • The gas valve is out of order.
  • Reduced ignition power.
  • Lack of gas.

"A02" warns of the presence of a flame when the burner is off. The cause of this signal may be a malfunction of the electronic board or electrode.

"A03" is overheating protection. It is worth noting that each operating mode has its own operating temperature values. In general, the system gives 10 to 50 seconds of temperature stabilization time. If at this time there is a decrease to 100 degrees, then the shutdown does not occur. The increased temperature does not lead to an error only if the burner is not ignited.

The reason for overheating, due to which the Ferroli diesel boiler can turn off, lies in:

  • pump malfunctions;
  • lack of normal circulation;
  • the presence of air in the system;
  • sensor malfunction.

"A06" indicates flame instability. Most often, this error appears if 6 or more extinguishing of the burner flame occurred in 10 minutes of time. May be caused by low fuel pressure or clogged passages.

  • "A09" informs about the failure of the gas valve.
  • “A16” indicates a gas valve malfunction, namely gas leak in closed position.
  • "A21" occurs if the combustion process is not correct. Appears if the "F20" error occurs 6 or more times in 10 minutes. Leads to restart.
  • "A34" informs about voltage surges, increase or decrease.
  • "A41" temperature sensor error, which may indicate a malfunction. If the sensor does not register an increase in temperature as a result of the test, the boiler will be blocked.
  • "A51" obstruction of the flue gas outlet or air duct.

Ferroli boiler errors categories "F"

  • "F08" indicates overheating in the system, but unlike "A03" does not turn off the boiler. The error appears when the sensor detects a temperature of 99 degrees. When the value drops below, “F08” will disappear from the display, but the record about it can be found.
  • "F20" combustion check. If the system detects that the combustion process deviates from the norm, then adjustment takes place. When the combustion adjustment failed, the burner turns off and an error appears. After 50 seconds, the system automatically starts up.
  • "F35" can indicate a discrepancy between the current frequency and the system settings. To do this, you need to make the appropriate settings and the error will disappear.
  • "F50" informs about improper operation of the modulation coil or an open circuit.

Unspecified faults

The absence of a programmed code does not mean that other breakdowns do not exist in nature. Does the Ferolli boiler have faults that are not included in the database? Yes, it has. To determine them, you will have to work seriously, you will need a good knowledge of all the elements of the system. Otherwise, you need to call the master.

One of the most common reasons for this is the banal closure and disconnection of the contact on sensors and any other electrical parts. Failure or lack of contact on the water pressure switch also belongs to the list of critical situations.

The work of electronics is possible only in a complex. If a sensor starts to show an incorrect value, this will affect the operation of the entire system. Upon detecting this deviation, it will shut down.

In conclusion

Diesel boilers Ferolli are one of the most reliable. The quality of materials and workmanship does not cause complaints from the most demanding users. Their use at home brings warmth and comfort to the house, and most importantly, they are quite multifunctional and capable of performing additional functions.

Ferroli boilers - Experts answer questions

Question:

The Ferroli Domiproject f24 boiler worked normally for a year. Then he began to work intermittently. It works for a few seconds, goes out and lights up again, and so on all the time. Both during heating operation and during DHW operation. I checked the chimney system, everything is fine. Replacing the prestat gave nothing. I removed the plugs on the top cover of the boiler, it did not help. When I remove the casing of the sealed chamber, it works fine. What
could there be a reason?

Answer:

If the boiler does not show any error and the voltage is more than 200 volts, then the heating heat exchanger is most likely clogged. You can check by connecting a heating sensor for a few minutes in the air or, which is easier, by reducing the gas with a tap in front of the boiler. If the burning interval has increased, then flushing is needed.

Question:

The Ferroli Domiproject f 24 boiler does not cope, the coolant temperature does not rise above 40, and the potentiometer is 70. The heated area is 70m2. And indoors it is 12 degrees. What should be done?

Answer:

This means there is not enough flow. Here's what you need to do: check the return filter, check the pump power and find out if the main heat exchanger is clogged.

Question:

When the heating system is turned off, the pressure in the system drops to 0 (approximately a day to 0.5 when the ECO is off; or to 0 when the ECO is on in a few hours) and the DHW is also cut off accordingly. I add water. The pressure drops again after a while. When the heating is on, the pressure does not drop or does not drop very noticeably. Make-up once every 1-2 months.

Answer:

First of all you need expansion tank pump with nitrogen - air up to 0.8 bar - with the pressure on the water pressure gauge in the boiler = 0. And then look for a leak, check the explosive valve, whether water is leaving it.

Question:

After installing the boiler Ferroli Domiproject 24 head hot water was almost at the level of pressure cold water... Six months later, the pressure dropped. What could be the reasons? If this is scale formation in the secondary heat exchanger, then how to flush it and how, as well as how to avoid scale formation?

Answer:

This boiler does not have a secondary heat exchanger, here it is bithermal, and in it scale is formed in winter mode, especially when the flow sensor is not working and when hot water is leaking. You can wash it with sulfa acid, for example, or hydrochloric acid.

Question:

Please tell me, if the boiler is completely out, nothing burns and does not turn on, although the 220 comes on board, the fuses and varistor are intact, what has burned out?

Answer:

Switching power supply on board.

Question:

The Ferolli boiler worked for 2 weeks normally, after the arrival of the master from the service center for the first start of the hot water supply, it lights up and blows off the flame. If I screw on the gas cock, it works fine. The heating works normally and with the gas tap fully open. How to fix it?

Answer:

If you can adjust the gas valve yourself, the instructions describe the procedure well enough, if you are not sure it is better to call a specialist again. It is necessary to adjust the MAX on the gas valve - with the "reset" button, go to the test mode, press the heating knob three times in the MAX if the flame breaks off with a key 10 counterclockwise, and then with the "reset" button go to the test mode, adjust the power for heating and ignition with the heating temperature knob -power for heating with a knob of water temperature-ignition. Procedure 5 minutes

Question:

Hello, I have a problem with the hot water supply; the ventilation hatches are turned off regularly and the heating has already been opened and the heating is turned off with the hatches closed. How to be?

Answer:

If everything is in order with the chimney, then the sensor - pressure switch must be checked.

Question:

Ferroli boiler in hot water supply mode. Periodically, in standby mode, the upper and lower LEDs start blinking (at the same time). When hot water is turned on, after 3 minutes the burner goes out, although the burner activation LED is on. Also, periodically, when hot water or heating is on, the upper and lower LEDs begin to flash alternately. Stabilizer ON-LiNE with inverter output
sinusoid and 220. The boiler has one heating season.

Answer:

First, check the dual temperature sensor.

Question:

The Ferroli Domiproject boiler has been in operation for 1 month, it worked normally and in one night it began to make strange sounds similar to strong boiling (it was heard through closed door). The unit was turned off until morning, in the morning I checked the pump, the supply voltage (there is a stabilizer) - everything is normal. I started the boiler - the sound returned, I think the scale was formed - I washed the heat exchanger, nothing helped - at a temperature of 40 and above, cacophony begins, if you open hot water - the sound disappears, you close it - it appears again.

Answer:

Perhaps the filter on the return line is clogged, the flow through the heat exchanger is low - the heating system.

Question:

When the heating circuit heats up, above 55 degrees, the heat exchanger begins to make noise, as if boiling. Could the DHW temperature be exceeded due to a large circulation in the heating circuit? I set the temperature with a heating potentiometer from 45 to 60 degrees. For half an hour, the boiler was gaining temperature, then it began to emit hissing sounds, did not wait any longer, turned the knob to 55, the burner turned off.

I watched the parameters of the gas pressure, after ignition in the furnace, the pressure on the burner maximum, after about 10 seconds, drops to a minimum, so it burns for about five minutes, then starts adding 10 pascal and stops. Somewhere at three millibars, it starts to make noise, it works for another three minutes, then after dialing a temperature of 55-60 degrees, it turns off.

I cleaned the boiler (pump, heat exchanger, furnace, filter) - it did not help, then I set the lower gas pressure setting to 40% lower than the passport one - the noise disappeared at 60 degrees. The paradox - you remove the cover of the closed combustion chamber - the boiler does not make noise. When you put it on, it starts to make noise. What could be?

Answer:

Or scale in the heating circuit or some kind of dirt. It is necessary to rinse with a booster, if it helps - well, it does not help - install another heat exchanger or another boiler with separate heat exchangers.

Question:

I have the following problem. Ferroli boiler DOMIproject C24. When you turn off hot water circulation pump the heating circuit may not turn on. It does not turn on until the burner is ignited for heating. The water in the boiler boils and the red LED starts blinking. The boiler gets into an accident. This happens several times a day. How can you solve this problem yourself?

Answer:

Clean the DHW flow sensor.

Question:

The 2A fuses on the Ferroli DOMIproject C24 boiler burn out. What can be done?

Answer:

Just like that, the fuses cannot burn, you need to look for where the short circuit occurs, leading to the fuse burning. First, check the pump operation.

Question:

I bought a Ferolli boiler and installed it. Uninterrupted SMART APC 750. Hot water goes without problems. I turn on the heating, it gives an error "overheating protection has worked." The pump is not working. What to do?

Answer:

Unlock the pump shaft. If that doesn't help, connect the pump directly. If it does not work, replace the pump. If it does not help, the fee is for repair.

Question:

There is such a problem. When the hot water is turned on, the Ferroli Domiproect F24 boiler periodically turns off the heating, and then starts up again. What could be the problem? The board has been replaced.

Answer:

It is necessary to adjust the operation of the gas valve - minimum power.

Question:

Tell me what could be. When I turn on the boiler, the red and yellow lights immediately turn on (they often blink, what can be in addition to the sensor? am I wrong?

Answer:

If you bridging the wires, the error does not disappear, the sensor needs to be replaced.

Question:

Ferroli DOMIcompact c24 boiler. Reduces pressure to 0. There are no leaks in the system. It appears to reset when hot water is on. Cold water supply pressure 2-3 atmospheres. The boiler worked for two years.

Answer:

There may be a breakdown between the circuits, and the pressure drops below the cold water supply pressure due to ejection. You most likely have a different problem! The expansion tank has lost air. The heating system cools down and the pressure drops when you turn on the DHW.

Question:

Tell me, is it possible to adjust the minimum pressure switch so that the boiler turns on at a pressure of 0.8 bar?

Answer:

There is an adjustment screw on the pressure sensor under the cap on the top.

Question:

Ferroli boiler Domicompact C 24 kW. There is a problem. The chimney is clean, the water and gas pressure is normal, but the boiler works as it pleases. I put 45C heats up normally, then like crazy. Turns on at any intervals. There is a leakage of the make-up tap into the heating system, but after the make-up I shut off the taps for supplying and dispensing hot water. What do you advise?

Answer:

Repair the make-up valve, check the NTC sensor (replace). According to NTC data, the boiler is turned on for heating. When t changes, the NTC resistance changes. If the readings are incorrect, then the boiler is also turned on inadequately. Alternatively, you can check the variable on the board.

Question:

Ferroli domicompact F 24 boiler, 4.5 years. The heat exchanger leaked last year. They called the master - sealed it. This winter, another problem arose: The heating temperature jumps set to 60 C, and the pipes are heated up to 80 C. The pressure at the same time rolls over to 3.5 bar. Or it drops to 0. Tell me what is the problem?

Answer:

Replace NTC, bleed volume compensator and make maintenance.

Question:

The Ferroli Domicompact F24 boiler works with the room thermostat jumper removed. The problem surfaced when I connected the thermostat (COMPUTHERM Q7 RF). For a while, everything worked fine, then after opening the contacts in the thermostat receiver, the boiler continued to work as it did. Depending on the position of the temperature regulator, heating takes place, heating is turned off, the pump drives water. Thermostat
connected correctly and works for closing-opening - checked by the tester.

Moreover, when to turn it off completely, i.e. the jumper is removed the boiler is working, the DHW regulator in which position is on off does not matter - everything is the same. Sometimes, after turning on the DHW, it turns off and then (as expected) works normally from the thermostat. Sometimes, after turning off the thermostat, it tries to start, but immediately turns off, so several times, after which the pump runs for 6 minutes and the boiler turns off. If possible, tell me what's the matter?

Answer:

Check the wires going from the board to the room thermostat connector. When the circuit is closed (or the thermostat has closed the contacts) - the boiler operates for heating, when it is open - it waits for the contacts to close to turn on the heating.

Question:

There is such a problem: the Ferroli DomiCompact F24 boiler works perfectly from the 220V network, and when the Leoton 500 watt converter is connected, the gas does not ignite. What to do?

Answer:

Turn the fork over.

Question:

I have a Ferolli DOMIcompact C24 boiler. Everything worked fine, and then suddenly, when the heating of the apartment was turned on, the pressure on the boiler began to rise sharply to 3 bar. To make it clearer: The boiler does not work - I set the pressure to 1 (I hear a clicking sound, the light stops blinking). I set the temperature to 40. The device starts up and starts heating the water.

Literally, in 5 minutes, the pressure rises sharply to 2.5 and more. (This was not the case before.) I drain the water from the system (through the tap on the return line), thereby reducing the pressure. And I do this until the water heats up to the desired temperature. When the water warms up, I drain the water from the tap and set the pressure to 2 bar. When the boiler works constantly at this temperature and does not turn off (in winter), the pressure remains unchanged (sometimes it increases slightly).

And when you turn off the heating of the heating system, the pressure drops below 1 and the device does not ignite. You have to open the make-up tap and draw up water in order to increase the pressure to start the boiler. It is summer now and the heating system is not working. I set the pressure to 1.5 to heat the water. This is how it has been for 2 months already. Tell me what is the problem?

Answer:

The problem is the lack of air in the expansion tank.

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

_______________________________________________________________________________

Since 1955, Ferroli products have been known to consumers all over the world. Gas boilers from this manufacturer are of high quality and reasonable cost. But only for 15 years this equipment has been sold in Russia. Over the years of the existence of products in the domestic market, gas boilers of the mentioned manufacturer have earned positive reviews from buyers and specialists who carry out installation work.

Positive reviews

Italian technology Ferroli characterized by ease of settings, excellent design and ease of use. The company has been on the market for over 50 years, and this is not much when compared with other manufacturers. But during this time, the brand has become one of the European leaders in the production of heating equipment.

Consumers note that the equipment is constantly being modernized, and its appearance features an increasingly attractive design. The devices meet safety and performance requirements, which is important for the consumer, as well as maintainability and ease of maintenance.

If you are also interested in the products of the Ferroli company, you can consider the gas boilers of this manufacturer in more detail. For example, mounted models are the most popular in Russia and are presented for sale in a wide range. They are compact and practical. According to users, such a boiler - perfect option for heating an apartment or house of medium size. The range of mounted boilers is quite wide, the manufacturer offers many models to the attention of users, this allows you to choose the desired configuration that will meet all the requirements. Owners of real estate of a more impressive area can consider Ferroli floor products, gas boilers of this line are highly reliable and durable.

Environmentally friendly and economical

Such equipment is perfectly adapted to the conditions reduced pressure in system. But the PegasusF2 model has two stage burner, which ensures the efficiency of operation and durability of the units. The air during the operation of such a device is much less polluted. This modification, according to users, can be used even for the installation of cascade heating systems. If you additionally purchase a controller, then create a system of 4 boilers, the total capacity of which can reach 1 MW.

Manual

Quite often recently, consumers have chosen devices from Ferroli. Gas boilers, which can be floor-standing or wall-mounted, must be operated according to the instructions. The company also includes an operating manual for each device. If malfunctions occur during operation, the consumer should contact the technical support specialists. Alternatively, the owner of the equipment should consult the user manual.

The most popular problems that can arise is a low pressure level, the device will report this with an f37 error. In this case, the user should check the gas and water supply and clean the system. If you do not want to face malfunctions, you must remember that when the equipment is disconnected from the power supply system or the gas main, the anti-freeze function will be disabled. In order to exclude damage from freezing, which can occur during prolonged shutdown of the boiler in winter period, the water should be drained from the boiler, this also applies to the heating system, as well as the hot water circuit. Otherwise, the water is drained only from the DHW circuit, and antifreeze is added to the heating system, and you should read the manufacturer's recommendations.

User manual gas boiler Ferroli indicates the possibility of adjusting the room temperature, this can be done using an optional thermostat. The latter allows you to set a specific temperature. If you need to adjust the temperature of the water in the heating system, use the remote control or the interactive panel on the device.

Installation nuances

The wall-mounted installation instructions for which are presented in the user's manual must be installed in a room where the ventilation system is constantly operating. If the air supply is insufficient, the device will not be able to work properly, and the combustion products will not be removed. If such conditions are created, then harmful substances can penetrate into the premises of the house, which can harm human health. If you purchased hanging equipment, you can use the bracket kit that attaches to the wall. A metal template can be supplied on special order to mark the surface of the suspension points.

Basic malfunctions and ways to eliminate them

The Ferroli gas boiler diagram will allow you to understand what design features possesses the purchased equipment. Some home craftsmen are also able to figure out the causes of the malfunction, as well as fix the problems on their own. If the device does not turn on, then there may be no gas in the network, but when the water pressure drops in the boiler, the main reason may be a malfunction of the circulation pump. Similar problems sometimes arise with insufficient ignition power, in this case it is necessary to increase it. However, damage to the electronic control board of the boiler cannot be ruled out.

If you have purchased a Ferroli gas boiler, malfunctions may also be expressed in extraneous noise inside the device. Only the master is able to cope with such a problem, and it is necessary to contact the support service as soon as possible. If the water pressure drops, the water supply system may be clogged, so the plug should be removed immediately.

Sometimes the repair of Ferroli gas boilers is not required at all. If you are faced with the fact that the equipment does not turn on, then you can try to unplug the plug and after a few minutes plug it back in again. If after that nothing has changed, then you should contact the wizard for help.

Conclusion

In the event of a breakdown of the components of the gas boiler, you can replace them. For example, gas-burners quite often they are made of steel. Despite the fact that these components are highly durable, they can be damaged by mechanical stress.

I'm afraid the worst, but I have to ask the specialists. Another thunderstorm passed, it sparkled, and the gas boiler stopped turning on, we have Ferroli F24. The first thought is everything, PPC, discharge, the end of the board. But the stabilizer still works, maybe you can get by with a little blood? Where to start looking, what are the options? If I call a specialist right away, then they will surely be divorced for a fee ...

First, check the stabilizer. Works? Then check, if you can yourself, there are all fuses in the boiler. Whole? Check the fee. Look for broken thyristors, swollen capacitors, burnt-out relays, etc. Found it? Look for a schematic or similar work board to calculate the markings for burnt parts. If this does not mean anything to you, call the master. And for the future - check the electrical connection of the boiler, including grounding.

The Ferroli gas boiler stopped turning on, what could be?

If you are not friends with a soldering iron, it is better not to climb into the board! This is a repair for specialists of a high category, it is just that it is difficult to determine the malfunction. Needed here soldering stations, tester, stock of parts and almighty google.
All you can do is check the fuses and power contacts. If the problem does not reveal itself in them, take the fee to the specialists, they certainly know what the problem is.

The Ferroli gas boiler stopped turning on, what could be?

20 Mar 2013, 07:46

The guest wrote: Another thunderstorm passed, it sparkled, and the gas boiler stopped turning on


Why is the boiler not grounded? According to the "Electrical Installation Rules" (PUE), if the boiler is electrically dependent, it must be connected to a common ground loop. The grounding circuit is not made separately for the boiler.
In general, grounding work is usually performed when installing the boiler and connecting it to gas. Then the electrical laboratory must measure and issue a protocol, which is attached to executive documentation for the installation of a gas supply system. It is not worth saving on this, this is electric and gas safety, your life depends on it.

Today the gas boiler - necessary thing in every house. Every year, residents of our country have to deal with planned and unscheduled outages of hot water. And private houses and many new buildings, in general, are designed only for individual heating. As a result, sooner or later, many of us have to think about purchasing a boiler or boiler. This article will focus on gas boilers by Ferroli. Let's talk about the types of heaters, their operation and possible breakdowns.

Views

Ferroli is an Italian company that produces various household appliances from heaters to various air conditioners. For the first time she declared herself in the middle of the last century. Over the decades of its work, Ferroli has become an international company with branches all over the world, including Russia. In our country, their products are known for their high quality and affordable price... Heaters are the main layer produced by the engineering firm. Basically, their varieties depend on the power source. Accordingly, they are:

  • gas;
  • electric;
  • solid fuel;
  • diesel.

This article will focus on gas boilers. They, in turn, are also divided into subspecies according to their parameters. Let's take a closer look at them.

  • Single-circuit- the simplest version of boilers. Aimed exclusively at space heating. They are not capable of heating water, which means that in addition you will have to purchase other equipment. But single-circuit boilers have high reliability, which is ensured internal device... Its main elements include a heat exchanger, expansion tanks and circular pumps.

  • Double-circuit- they are solving the issue of purchasing additional equipment for heating water. This equipment is aimed at performing two tasks at once. These heaters are equipped with two heat exchangers. The water that circulates through the heat exchanger serves not only to heat the room, but also to provide hot water supply.

It is worth noting: a double-circuit boiler is in no way superior in size to a single-circuit one. But because of complex structure the level of reliability decreases. By the way, there is a bithermal subspecies of double-circuit boilers. Its peculiarity lies in the fact that one heat exchanger is located inside the other. With this structure, boilers become the least reliable.

  • Open camera combustion- heaters that require an inflow of oxygen from the external environment. Therefore, the occupied space must be equipped with ventilation and a chimney. The latter is necessary for the removal of combustion products. Before installing such a boiler, the room will have to be prepared according to all the rules fire safety... This type of boilers has a simple structure, high reliability, and low productivity. The models make little noise during operation.

  • Closed combustion chamber- such boilers are the least harmful to the environment. They work with a special burner. Among other parts, there is a fan that supplies air. It also removes combustion products, so it doesn't matter if there is draft in the chimney or not. This type of boilers is the most efficient, but less reliable. Often there are problems with the fan. By the way, it makes a lot of noise during operation.

Many of these models are condensing. That is, they differ in low fuel consumption with a fairly high efficiency. Others (convector boilers) lose a lot of heat along with combustion products, which is a serious disadvantage.

  • Wall mounted- the most popular type of gas boilers. The demand for them is due to their compact size, affordable price and sufficient performance to heat an apartment or private house... They are also easy to install due to their low weight. This type usually has a closed combustion chamber.

  • Floor standing- a powerful type of boilers designed for heating large rooms... Their dimensions and weight are far superior to those of wall heaters. The price is also noticeably higher. Such boilers are rarely used in everyday life.

The lineup

Ferroli products boast a wide selection of various models. You can choose a heater based on any requirement. However, not all of these models can be presented in Russian stores. household appliances... Fortunately, today Internet services with a delivery service can always come to the rescue. Consider the most famous and common boilers from the Ferroli company.

  • Domina N- one of the new models released in 2013 to replace the old boilers that were discontinued. The unit belongs to the bithermal subspecies, that is, it has two heat exchangers and the second is located inside the first. They are made of copper and coated with a heat-resistant substance that increases their service life. Wall mounted boilers this model can have both a closed combustion chamber and an open one. Domina N is distinguished by a long range of advantages, including: pleasant design, small size and weight, electric ignition function, anti-blocking pumping system, frost protection, the ability to connect a remote control, high efficiency, safety and reliability.

  • Ferroli diva- another modern wall-mounted boiler. It has two heat exchangers to heat the room and supply hot water. Equipped with a simple and accessible control panel with digital display. Like the Domina N model, it has subspecies with different combustion chambers. Among the advantages of Ferroli Diva, one can note an elegant appearance, ease of installation and maintenance, electric ignition, an efficiency level of 93%, self-diagnosis, safety, plate heat exchanger for hot water, anti-corrosion compound, coating steel chamber combustion, and an electronic board for power modulation.

  • Divatop micro Is the newest of the models featuring a number of innovative features. A rather popular boiler today. Boasts enhanced efficiency and reliability. Consists of two separate heat exchangers made of copper. And three-way inverter valves provide ease of use. The boiler program is capable of independently supporting set temperature for a long time. This model has an innovative self-diagnosis system that ensures maximum operational safety.

The Divatop Micro price may seem overpriced in comparison with analogues, but at the same time the boiler is equipped with a full set of accessories that make it much easier to operate. Other advantages include a variable speed fan, LCD display, automatic system recognizing weather conditions, wide functionality and convenient location of internal components.

  • Pegasus 23- a popular model of floor standing boilers. They are chosen, of course, less often than wall ones. The point is the high price and power, which is not needed to heat a house or apartment. But some people own large cottages that are not easy to heat with a medium-sized boiler. Here the Pegasus 23 comes to the rescue, whose power reaches 23 kW. The cost of the model can reach 50 thousand rubles. It is due to the presence of a cast iron heat exchanger, which ensures maximum boiler reliability. It is also resistant to corrosion. The boiler is equipped with elements such as a thermometer and a pressure gauge.

  • Bluehelix Tech 35 A- wall-mounted boiler, superior in power to some floor-standing ones. Designed specifically for heating large rooms. The model is a condensing type heater. Combustion chamber type - closed. The maximum power is over 32 kW. At the same time, the boiler is very reliable. The Bluehelix Tech 35 A is based on a stainless steel heat exchanger. In addition, an 8-liter expansion tank and a circulation pump are available. The filling dictates a solid price - about 65 thousand rubles.

  • Atlas D30interesting model capable of operating on both gas and liquid fuel. This boiler is single-circuit and has cast iron heat exchanger... And its thermal insulation is made of mineral wool... The maximum power of the unit is 30 kW. Of the advantages, one can single out high level Efficiency exceeding 93%, the ability to connect an additional boiler or other external panels, as well as a low amount of electricity consumed. However, there are also certain disadvantages. To use the boiler, you will need a hinged burner, which will have to be purchased separately.

  • Fortuna PRO 24F- one of the most demanded wall models... It boasts positive reviews from the owners of private houses, because the unit is intended for heating them. It is able to provide heat to an area of ​​240 square meters. In addition, the boiler will delight you with hot water supply. Maximum power - 25 kW, efficiency - 93%. The heat exchangers inside it are separate. Combustion chamber type - closed. There is an eight liter expansion tank. By the way, if desired, the heater can be converted to work on liquefied gas.

  • Econcept Tech 18A- stands out from other models with its flexible adjustment system. But alas, it is not able to boast of high power, whose maximum does not exceed 18 kW. The same can be said about average reliability indicators. This is due to the aluminum alloy from which the heat exchanger is made. But among the advantages is an increased level of security. It is achieved by a self-diagnosis function, an auto air vent, a safety valve, electronic flame modulation and other useful systems.

Launch and control

Most modern models are equipped with automated systems management. If not, they can be purchased separately and connected, which will significantly simplify the operation of the boiler. To run correctly gas heater from Ferroli, you must first connect it to the mains and turn it on by pressing the "start" button. It may take about 15 seconds for the boiler to start up. Then open the burner and fire up.

To switch off, close the valve and press the corresponding button. It is also recommended to disconnect the boiler from the power supply, however, if disconnected completely, the heater may freeze. To avoid this threat, you need to drain the water entirely. You can also add antifreeze to it.

Remote controls make it much easier to set up the work. Moreover, the adjustment in all models is carried out according to the same scheme. You can install such a remote control in any room, and you do not have to visit the boiler every time you need to change the parameters. You can manually change the room temperature or heat exchanger temperature, set a specific operating mode, activate the comfort function or reset all presets.

Also, with its help, you can give commands to the boiler sensor and set the expansion tank settings. And the digital display, which is almost always present on the remote control, will notify you of any errors. This feature greatly simplifies maintenance. Accordingly, the service life also increases.

Malfunctions and repairs

Even if your boiler is of European quality and enviable reliability, sooner or later you will encounter certain breakdowns. But don't worry. Any modern model will try to notify you of this and tell you exactly what the malfunction is. She does this using a display or color indication. In the second case, the indicators on the control panel start blinking. Why is the boiler not heating the water and the red light is blinking? What does it mean - bad ignition? Answers to these questions and a detailed designation can be found by referring to the instructions or special Internet sources.

Consider the error codes that are displayed on digital screens.

  • A01 - no flame. This error means that the system has made several attempts to light the fire, but none have been successful. Valve closed or gas pressure too low. Also, the problem may lie in the incorrect connection of the electrodes. Examine the wiring. If everything is in order, restart the equipment. The control board may also malfunction.

  • A03 - the boiler has overheated. An emergency sensor registers an increased temperature and shuts down the equipment until it returns to normal. The reason is often a violation of the water circulation. This happens because of low pressure or if air enters the system.

Keep in mind that the sensor itself can also fail and register incorrect readings. In this situation, it should be replaced.

  • A06 - ignition was carried out, but there is no torch. This error occurs when the gas pressure is low.
  • A08 - the overheating sensor is out of order. First of all, check its wiring for breaks. If everything is in order with it, the sensor must be replaced.
  • F05 - the process of removing smoke from the room is violated. Usually the problem is with the air pressure switch. Pay attention to the correct connection of the connections.

Also, the problem may lie in the heater diaphragm. However, most often the code is displayed due to a clogged chimney. Just do the cleaning.

  • F10 - two reasons. First, a short circuit has occurred. The second - somewhere in the temperature sensor circuit there was an open circuit. Check if there is a contact between the sensor and the control panel. The problem is solved by reconnecting the wiring. Find out the resistance of the sensor at the moment. If in all respects it is faulty, replace it with a new one.
  • F14 - problem with the second sensor of the pressure head heating circuit. Most likely, it is damaged and needs to be replaced with a new one. Either a short or open circuit has occurred.

  • F34 - voltage electrical network too low. The boiler generates an error when it falls below 180 V. If the problem occurs too often, it is recommended to connect the boiler to a stabilizer.
  • F37 - the pressure level in the heating system has dropped noticeably. The relay contacts open. If it is faulty, replace it. And inspect all heating system leaks may be found in it.

  • F39 - there is a short circuit or an open circuit in the outdoor temperature sensor. Check resistance and wiring between sensor and control panel.
  • F50 - the gas valve modulation coil is faulty. It should be ringed to identify an interturn short circuit or an open circuit. Check gas valve... There may be an error in the operation of the control panel. Perform a reset.

Some of the problems can be solved by hand. For example, deflating or raising the pressure is not difficult. You can clean the heat exchanger if you already have experience in this matter. But in most cases it is recommended to call a specialist or contact service center... Wizards will carry out detailed diagnostics and troubleshoot without causing harm to the system. And in order for breakdowns to occur as rarely as possible, you should follow a few simple rules. Spend at least once a year Maintenance and cleaning. Replace damaged parts to avoid over serious breakdowns... Don't skimp on installing a heater. Entrust this business to the masters who will do everything right.