A radial-type fans are belonging to the brand, which contains the wheels in their design with rebel. As a rule, they have a high efficiency, and during operation there is no discomfort from the noise of their motor. Van® trademark was first registered in 2008 and from that time it is considered a sample of comfort and modernity. Each fan is manufactured using the most recent technical developments, as well as the latest equipment. Cutting of all composite products (blades, wheels for wheels, housing walls) is performed using a laser. But the formation of details of conical and toroidal types is performed using a CNC controlled. In this case, welding wheels are carried out using a special welder robot.

Each body of the ventilation products is made of galvanized steel using sunset technology.

Since the production of fans is carried out on high-precision equipment, the serial products fully corresponds to the reference characteristics declared by the manufacturer. This guarantees constant high quality of each fan. Trademark Van® manufactures its products in 16 sizes, providing the widest choice of device performance, which is in the range of 300-120000 m3 / h, and the pressure indicator is about 2600 Pa.

As a rule, the fans from the Van are used in those systems where the functioning technology requires a high efficiency, low noise level, or a set of multiple fans that will work in parallel to each other. Such products have high technical parametersand can also completely replace the famous fan series domestic production (VC 4-70, BP 80-75, BP 86-77). It is over compared to them, the products of Vran have a number of advantages:

  • there are several classes of wheel execution that depend on the size of the circumferential speed. It is the wheels that serve as the basis for the reliable operation of the fan mechanism throughout its entire period of operation. All calculations of the working wheels, which use the finite element method, fully comply with experimental data;
  • when choosing engines, the manufacturer optimized power reserves, which, ultimately, allows the use of structures with a small installation capacity, which is particularly important for small numbers fans;
  • the use of fans of all numbers, which are made on the first constructive scheme. Each of them contains frequency converters, which makes it possible to accurately correct the mode of operation of the device during commissioning tests, as well as during the further operation of the fan. Developed and successfully implemented a technique for selecting an engine for optimal sizes, which is capable of working with frequency converter and change the frequency range of the current used;
  • high aerodynamic performance indicators are provided by a simple design of the wheel, as well as seals, which is between the wheel and the nozzle when used in the design quality technology assembly;
  • the shape of the spiral case was slightly changed, due to which the average speed of the air flow is reduced in the output section of the device, the pressure loss in the adjacent ventilation network is also reduced.

The main purpose of the fans Van

Fans can be installed in ventilation systems standard type, as well as in the air conditioning system and air heating Buildings in production or in residential premises. To travel during two hours gas-high mixesThe temperature of which is within 400-600 ° C, could not harm the fan, it is manufactured using special VANA® type versions) Du.

Fans are such types of versions:

  • general industrial, which manufacturer, as a rule, marks the sign "H";
  • heat-resistant, which are labeled as "F";
  • anti-corrosion (K1), which may interfere with the formation of corrosion and rust;
  • corrosion-heat resistant (k1zh) - such fans combined two types of mechanisms and their properties;
  • explosion-proof (marking type "B") - products are performed according to only the first constructive scheme;
  • heat resistant, the mechanism of which has protection against explosions (VZH) - execution similar to the previous type of fans;
  • fans that have a protective mechanism from the explosion and corrosion formation (VK1; VK3);
  • explosion-proof corrosion-heat resistant (VK1ZH);
  • fans are resistant to seismic activity that can be easily combined with other types of versions that are listed above.

    Mechanism of fans from within

    In its design, each fan has a impeller, which rotates both in and counterclockwise. Wheel blades have a special shape and bent slightly backwards. The spiral body of the device is also able to rotate. Fan mechanisms are manufactured both in the first and fifth structural scheme according to the adopted 5976 GOST standards.

The fans performed according to the first structural circuit, are directly connected to the engine and there are two modifications of the VANR6 type and vran9. They differ in the number of blades of their impeller.

Fans, which belong to the fifth structural pattern, in its design contain a belt type drive. Such products are only one version modification. Unlike it, Vran9, which belongs to the first constructive scheme, is equipped with engines, thanks to which you can perform a frequency of speed control.
For the climate execution devices of types U1, UHL1, T1 in the design of the mechanism is provided additional protection From atmospheric precipitation, which is equipped with a drive and exhaust part of the fan.

Fans that are used on large industrial enterprises, have a noise insulating casing, which makes it possible to largely reduce the noise level of the device to a value of 12 dB. In this case, the overall sound pressure level decreases by 25-30 dB at a distance of 5 meters.

If desired, the Customer may acquire additional components in the form of vibration insulators and flexible inserts that allow reduced dynamic loads. It will not be superfluous: reverse action flanges, frequency converters, and various devicesthat allow you to perform smooth start Fan.

Operational conditions
According to the operational rules and standards, so that the fans can serve their owner for many years, they must be installed outside the zone in which people are constantly being.

Products on the provisions of GOST 15150 are able to withstand a variety of climatic working conditions, ranging from moderate, and ending with a tropical climate.

Basic operating conditions:

the temperature around the device must match:
- "-" 45 - "+" 40 degrees Celsius for a moderate climate type;
- "-" 60 - "+" 40 degrees - for a moderately cold climate;
- "-" 10 - "+" 50 degrees - for tropics.
At the same time, the average value of the so-called vibrationability of all external mechanisms, which serve as a source of vibration oscillations, should be within 2 mm / s.

Overall and connecting dimensions of fans VRAN (1st version)

room
fan
n. n 1. n 2. n 3. dimensions, mm
A. A 1. A 2. B. B 1. B 2. D. d. d 1. t. t 1. L Max L 1. L 2.
VRAN-2,5 175 160 200 325 240 348 280 M67 80 54 8 14 2 3 460 89 86
VRAN-2.8. 199 200 222 362 300 383 310 M67 100 41,5 8 14 2 3 480 101 101
VRAN-3,15 217 200 240 399 300 420 345 M67 100 60 8 14 2 3 530 110 115
VRAN-3,55 249 200 272 454 400 475 390 M67 100 37,5 8 16 2 4 580 127 129
VRAN-4. 281 200 310 512 400 538 430 M8.9 100 55 8 16 2 4 640 143 145
VRAN-4.5 318 240 350 574 480 604 480 M8.9 120 55 8 16 2 4 770 160 164
VRAN-5. 353 300 380 643 600 668 530 M8.9 100 40 8 22 3 6 800 175 182
Vran-5,6 394 300 426 719 600 749 600 M8.9 100 63 8 22 3 6 865 198 202
VRAN-6,3 441 400 470 801 700 830 660 M8.9 100 35 8 26 4 7 975 222 231
VRAN-7,1 497 270 540 900 675 941 740 M8.9 135 135 8 18 2 5 1030 250 260
VRAN-8. 563 300 600 1009 750 1047 835 M8.9 150 150 8 18 2 5 1135 282 297
VRAN-9. 630 600 670 1132 1050 1170 940 M8.9 150 35 16 26 4 7 1250 318 335
VRAN-10. 703 450 750 1269 1050 1317 1050 M8.12 150 150 16 24 3 7 1340 353 366
VRAN-11,2 784 750 830 1424 1350 1463 1170 M10.12 150 40 16 32 5 9 1540 395 409
VRAN-12.6. 877 750 925 1593 1500 1638 1285 M10.12 150 87,5 16 34 5 10 1750 440 455
VRAN-14. 980 672 1040 1460 - 1512 - - 12 168 - - 30 4 9 2150 594 980
room
fan
Installation dimensions, mm Flexible insert on the side:
C. C 1 C 2. C 3. C 4. d 2. k. k 1. digging suction
VRAN-2.5 295 330 70 - - 10 70 - VG-N-2.5VG-B-2.5
VRAN-2.8 295 365 80 - - 10 75 - VG-N-2.8VG-B-2.8
VRAN-3.15 420 470 60 - - 10 75 - VG-N-3,15VG-B-3.15
Van-3.55 460 530 104 - - 10 90 - VG-N-3,55VG-B-3,55
VRAN-4. 520 610 127 - - 11 90 - VG-N-4VG-B-4
VRAN-4.5. 525 660 140 - - 12 100 - VG-N-4.5VG-B-4.5
VRAN-5. 525 695 160 - - 12 100 - VG-N-5VG-B-5
VRAN-5.6. 550 740 183 - - 14 110 - VG-N-5,6VG-B-5.6
VRAN-6.3. 550 830 200 - - 14 110 - VG-N-6.3VG-B-6.3
VRAN-7.1. 710 750 200 - - 14 125 - VG-N-7.1VG-B-7.1
VRAN-8. 800 845 222 - - 14 125 - VG-N-8Vg-B-8
VRAN-9. 870 950 258 - - 14 130 100 VG-N-9VG-B-9
VRAN-10. 960 960 218 - - 14 130 245 VG-N-10VG-B-10
VRAN-11.2. 1070 1090 245 - - 14 150 175 VG-N-11.2VG-B-11.2
VRAN-12.5. 1230 1200 235 - - 16 180 105 VG-N-12.5VG-B-12.5
VRAN-14. 2250 1060 1485 530 915 - 395 473 VG-N-14VG-B-14

Position of the body of the fan verso. No. 1.


room
fan
Overall dimensions, mm
0 0 45 0 90 0
B. b. H. h. B. b. H. h. B. b. H. h.
Van No. 2.5 456 186 240 173 423 190 240 312 390 173 240 270
Van No. 2.8. 515 213 310 193 471 206 310 349 441 193 310 302
Van No. 3,15 572 236 310 215 521 225 310 388 491 215 310 336
Van No. 3,55 644 267 350 245 590 256 350 438 557 245 350 377
Van No. 4. 738 301 390 290 686 310 390 514 641 290 390 437
Van No. 4.5 831 338 435 325 761 339 435 570 719 325 435 483
Van No. 5. 913 375 535 338 832 363 535 619 776 338 535 538
Van No. 5.6 1020 420 570 375 924 399 570 688 865 375 570 600
Van No. 6.3 1140 474 665 420 1034 442 665 768 973 420 665 667
Van No. 7,1 1282 534 745 480 1167 499 745 869 1103 480 745 748
Van No. 8. 1440 602 795 536 1304 553 795 972 1238 536 795 839
Van No. 9. 1615 677 890 590 1467 621 890 1078 1379 590 890 938
Van No. 10 1797 751 970 656 1627 689 970 1204 1533 656 970 1046
Van №11,2 2004 841 110 735 1822 764 1100 1342 1716 735 110 1163
Van No. 12.5 2235 947 1230 810 2050 869 1230 1487 1905 810 1230 1302
Van No. 14. 2760 1170 1365 965 - - - - 2350 965 1365 1590
room
fan
Overall dimensions, mm
135 0 270 0 315 0
B. b. H. h. B. b. H. h. B. b. H. h.
Van No. 2.5 515 202 240 234 390 173 340 186 515 202 340 190
Van No. 2.8 579 230 310 265 441 193 350 213 579 230 350 206
Van No. 3.15 644 257 310 296 491 215 410 236 644 257 410 225
Van No. 3.55 728 290 350 335 557 245 450 267 728 290 450 256
Van No. 4. 840 326 390 376 641 290 470 301 840 326 470 310
Van No. 4.5 936 366 435 422 719 325 535 338 936 366 535 339
Van No. 5. 1023 404 535 470 776 338 580 375 1026 406 580 363
Van No. 5.6 1143 455 570 525 865 375 665 420 1143 455 665 399
Van No. 6.3 1282 513 665 591 973 420 746 474 1282 513 746 442
Van No. 7.1 1447 578 745 667 1103 480 845 534 1447 578 845 500
Van No. 8. 1623 651 795 751 1238 536 895 602 1623 651 895 553
Van No. 9. 1811 733 890 846 1379 590 1010 677 1811 733 1010 621
Van No. 10 2017 814 970 939 1533 656 1100 751 2017 814 1100 689
Van No. 11.2 2253 911 1100 1051 1716 735 1250 841 2254 911 1250 764
Van No. 12.5. 2512 1025 1230 1181 1905 810 1430 947 2512 1025 1430 869
Van No. 14. - - - - 2350 965 1635 1170 - - - -

Overall and connecting dimensions of fans VRAN (5th execution)



fan
Connecting dimensions, mm n. n 1. n 2. n 3. Overall dimensions, mm
BUT A 1. A 2. IN IN 1 AT 2 D. d. d 1. t. t 1. L Max L 1. L 2.
6,3 441 400 470 801 700 830 660 M8.9 100 35 8 26 4 7 1080 222 231
8 563 300 600 1009 750 1047 835 M8.9 150 150 8 18 2 5 1200 282 297
10 703 450 750 1269 1050 1317 1050 M8.12 150 150 16 24 3 7 1540 353 366
12,5 877 750 925 1523 1500 1638 1285 M10.12 150 87,5 16 34 5 10 1710 440 455

fan
Installation dimensions, mm Insert flexible on the side:
FROM With 1. With 2 With 3. d 2. d 3. to to 1. to 2. digging suction
6,3 980 1110 245 - 12 18 120 140 320 VG-N-6.3VG-B-6.3
8 1156 1190 310 - 12 18 130 301 294 VG-N-8Vg-B-8
10 1456 1900 446 - 12 18 150 381 904 VG-N-10VG-B-10
12,5 1645 2025 550 2223 15 24 180 525 875 VG-N-12.5VG-B-12.5

Position of the fan body Van scheme number 5



fan
Overall dimensions, mm
0 0 45 0 90 0
B. B 1. b. H. h. B. B 1. b. H. h. B. B 1. b. H. h.
6,3 1140 1736 474 671 426 1034 1662 442 671 768 973 1623 420 671 667
8 1440 1833 602 843 536 1304 1746 553 843 972 1238 1697 536 843 839
10 1797 2676 751 1050 656 1627 2568 689 1050 1204 1533 2507 656 1050 1046
12,5 2235 2918 947 1230 810 2050 2811 869 1230 1487 1905 2725 810 1230 1302

fan
Overall dimensions, mm
135 0 270 0 315 0
B. B 1. b. H. h. B. B 1. b. H. h. B. B 1. b. H. h.
6,3 1282 1583 513 671 591 973 1490 420 751 474 1282 1839 513 751 442
8 1623 1646 651 843 751 1238 1531 536 933 602 1623 1967 651 933 53
10 2017 2444 814 1050 939 1533 2286 656 1150 751 2017 2833 814 1150 689
12,5 2512 2655 1025 1230 1181 1905 2440 810 1430 947 2512 3117 1025 1430 869

Radial industrial fans Van medium pressure are presented in two modifications of working wheels and with a thick-dimensional range of R20 diameters of wheels. This allows you to choose the optimal model on any mode of operation. The performance of the fans is from 300 to 150000 m³ / h, the maximum pressure is 2600 Pa. The aggregates of this type are used in injection systems and installations, where there are limitations on dimensions. Specifications Fans Van are not inferior to the indicators of imported analogs. The strength indicators are confirmed by appropriate tests.

Purpose

Van fans are installed in standard ventilation, air conditioning and air heating systems, the aggregates are suitable for production or residential premises. Especially effective in installations where there are hard restrictions on the overall dimensions of the fan. Suitable for copper ventilation.

The following versions of this model are presented:

  • N - general industrial;
  • Well - heat-resistant;
  • K1 - corrosion-resistant;
  • K1zh - corrosion-heat resistant;
  • B - explosion-proof - on the 1st constructive scheme;
  • VZh - explosion-proof heat resistant - on the 1st constructive scheme;
  • VK1; VK3 - explosion-proof corrosion-resistant - on the 1st constructive scheme;
  • VK1Zh - explosion-proof corrosion-heat resistant - according to the 1st constructive scheme;
  • C - seismic resistant.

Design

The main element of the fan design is the impeller with blades, bent back. The wheel is placed in a rotary spiral case. The inlet nozzle of a special cylindrical shape is placed outside the wheel, which ensures durability. The input flange is also not provided, due to which the air inlet on the suction side is more favorable. To protect the engine from atmospheric precipitation there is a separate mechanism. Engine three-phase asynchronous single-speed. Models Vran9 on the 1st scheme can be equipped with a drive with frequency control of the speed of rotation. Fans are able to operate in smoke mode or in the combined smoke and ventilation mode - in such models installed engines for a long continuous operation.

Operating conditions

Industrial fans are installed outside the premises on the distance from the places of permanent stay of people. Operation is allowed in a moderate, moderately cold and tropical climate when placing 1 and 2 categories. Permissible air temperature - from -45 to + 50ºС. If there is a source of vibration nearby, the vibration rate should not exceed 2 mm / s. To reduce the noise level, you can use a noise insulating casing.

The manufacturer offers the following versal fan options:

  • N - general industrial;
  • Well - heat-resistant;
  • K1 - corrosion-resistant;
  • K1zh - corrosion-resistant, heat-resistant;
  • B - explosion-proof (1st constructive scheme);
  • VZh - explosion-proof, heat-resistant (1st constructive scheme);
  • VK1, VK3 - explosion-proof, corrosion-resistant (1st constructive scheme);
  • VK1Z - explosion-proof, corrosion-resistant, heat resistant (1st constructive scheme);
  • C - seismic resistant.

Vintinform provides deliveries ventilation equipment To all regions of Russia. We offer Vran6 fans and breaks the following sizes:

  • VRAN6 number 2.5;
  • VRAN6 number 2.8;
  • Vran6 No. 3.15;
  • Vran6 No. 3.55;
  • VRAN6 number 4;
  • Vran6 No. 4.5;
  • VRAN6 number 5;
  • Vran6 No. 5.6;
  • Vran6 No. 6.3;
  • Vran6 number 7.1;
  • VRAN6 number 8;
  • VRAN6 number 9;
  • VRAN6 number 10;
  • Vran6 No. 11.2;
  • Vran6 No. 12.5;
  • VRAN6 number 14;
  • Vran9 number 2.5;
  • Vran9 number 2.8;
  • Vran9 № 3.15;
  • Van9 No. 3.55;
  • Van9 number 4;
  • Vran9 number 4.5;
  • Van9 number 5;
  • Van9 number 5,6;
  • Van9 number 6.3;
  • Vran9 number 7.1;
  • Vran9 number 8;
  • Vran9 number 9;
  • Vran9 number 10;
  • Van9 No. 11.2;
  • Vran9 No. 12.5;
  • Van9 number 14.

Among the partners "Ventenform" - leading domestic and foreign manufacturers of ventilation equipment, which guarantees high quality products. We offer our customers best prices And the most convenient conditions for purchase.

Plant Web is the largest manufacturer of ventilation equipment in Russia, including such a product as a centrifugal fan of general industrial purpose. The centrifugal fan of the BP-80-75 series or VRAN is the original verse name, the VC-14-46 or is used in the ventilation systems, air conditioning and air heating of various destinations.

Radial fans of Vran-Doo and the roofing fans are installed in special exhaust ventilation systems to remove gases occurring during fire and simultaneously removing heat outside the room. At the same time, the localization of the fire zone is ensured and the possibility of carrying out work to combat fire and to rescue people and equipment is being created. Installations can move gas-air mixtures with a temperature of 400 ° C and 600 ° C for at least 120 minutes.

Centrifugal fan BP-80-75 - replacement for fan Van at the request of the buyer.

Fans Vran. low pressure Made in the general industrial, heat resistant, corrosion-resistant, north and explosion-proof performance. Operating wheels of such a fan contain 9 or 6 curved vanes back. Due to the wide size of the working wheels, the centrifugal fan is very tightly closed the operating points in the main ventilation tasks.

A centrifugal fan is made by 1st (with a direct connection with the engine) and on the 5th (with belt drive) constructive design schemes. Performance from 1000 m³ / h to 100,000 m³ / h, full pressure from 100 Pa to 1800 Pa.

The centrifugal fan is applied in systems where high efficiency is required, low noise level and in systems with parallel operation of several fans.

Fan Vran9

Low Pressure Fans Vran6 and Vran9 serve to move gas and steam-air mixtures to which explosive can be attributed. Installations are used in stationary ventilation and air conditioning systems, as well as in air heating systems for public, industrial and residential buildings, as well as in industrial and sanitary purposes.

  • Fans corresponding to the first structural pattern are manufactured in 16 sizes.
  • Fans corresponding to the fifth structural pattern are made in four sizes.
  • Release according to TU 4861-105-40149153-2007;
  • Certified and certified for work in explosive industries.

Vran6 and Vran9 are released in the following versions, according to the operating conditions:

  • on the first and fifth structural scheme:
  1. general industrial (H);
  2. corrosion-resistant (K);
  3. heat resistant (g);
  4. corrosion-heat resistant (k1zh).
  • according to the first constructive scheme:
  1. explosion-proof (c);
  2. explosion-proof corrosion-resistant (VK1);
  3. explosion-proof corrosion-resistant (VK3);
  4. explosion-proof heat resistant (VZH);
  5. explosion-proof corrosion-heat resistant (VK1ZH);
  6. seismic resistant (C).

Van fans can be operated in the following weather and climatic conditions:

  • temperate climate (y). The ambient temperature from -45 to + 40 ° C and the average value for the vibration of external vibration generators at the installation site of the fan fan is not more than 2 mm / s.
  • moderate and cold climate (Uhl). The ambient temperature from -60 to +40 ° C and the average value for the vibration of external vibration generators at the installation site of the fan fan no more than 2 mm / s.
  • tropical climate (T). The ambient temperature is from -10 to +50 ° C and the average value for the vibration of external vibration generators at the installation site of the fan fan no more than 2 mm / s.

Advantages of fans Vran9:

    reduced installation power on the fan;

    reduced dimensions and weight;

    used new technology manufacture of galvanized steel housing;

    additional options for the use of flexible rates and vibration insulators are proposed;

    new, more thick, adopted in the world is a si-dimensional R20 series;

    an outlet is increased in accordance with European standards.

Vran-do fans

Vran-do fan It has an impeller of the left or right rotation with bent back by the blades of a special form, providing high efficiency and low noise. Spiral housing - swivel. According to the design scheme 1 (with a direct connection with the engine), all sizes of fans are made. According to a design scheme of execution 5 (with belt drive), fans No. 4 are made; five; 6.3; eight; 10 and 12.5.

The operating wheels of the fans are made of steel ST3 (for temperature to 400 ° C) and from steel 12x18H10T (for temperature to 600 ° C) with paint and varnish heat-resistant coating. The thermal protection of bearing nodes ensures reliable operation of the fan when moving hot gases.

Vran-Du fans for ventilation systems are installed in special inlet systems Smoke removal for creating overpressure (Puzzle) in staircases, tambura gateways and mines of buildings elevators to prevent smoke penetration into these rooms and create the ability to perform fire combat and to save people and equipment.

VROR-DU 6.3 fans are installed in special exhaust systems to remove gases occurring during the fire and at the same time removal of heat outside the room, can move gas-air mixtures with a temperature of up to 400 ° C and up to 600 ° C for at least 120 minutes. At the same time, the localization of the fire zone is ensured and the possibility of carrying out work to combat fire and to rescue people and equipment is being created.

According to the 1st structural scheme, fans of sizes are made: 5; 6.3; eight.

On the 5th structural scheme, sizes fans are made: 6.3; eight; 10; 12.5.

Production options

general industrial (H)
corrosion-resistant (K1)
Explosion-proof (c) - only on the 1st constructive scheme
Explosion-proof corrosion-resistant (VK1) - only on the 1st constructive scheme

Design

VRAN-DU fans 6.3 have an impeller working wheel of a drum type of left or right rotation with 32 bent forward with the blades. Spiral housing - swivel. He has an entrance nozzle cylindrical shape and not included in the impeller, which ensures reliable operation of the fan when high temperatures Movement medium.

Execution of VROR-DB 6.3 fans in a noise-insulating casing (manufactured for general industrial design and positions of the housings 0 and 90 degrees) reduces the total sound power, emitted by a fan by 12DB, due to the noise-absorbing and noise insulating properties of the casing. The total sound pressure level is reduced by 25 ... 30 DB at a distance of 5m.

An additional equipment is proposed with vibration and inserts and flexible inserts, which reduces dynamic loads, as well as flanges inverse and automation cabinet.

Exploitation

Fans should be installed outside the served room and the limit of the constant stay zone.

Fans can be operated in moderate (y); Moderate and cold (UHL) and tropical (T) climate of the 1st and 2nd category of placement according to GOST 15150.

Operating conditions

environmental temperature
from minus 45 to + 40 ° C for temperate climate
from minus 60 to + 40 ° C for temperate and cold climate,
from minus 10 to + 50 ° C for tropical climate;

the average value of the vibration of external vibration sources in the fan installation places is not more than 2 mm / s;

Purpose and Description of the fan Vran6-071 To remove gases.

Fans are certified and have permission to use on explosive and chemically hazardous industries and objects.

Design and execution

    • Typesimile: 400; 450; 500; 560; 630; 710; 800; 900; 1000; 1120; 1250 mm - 1 standard;
    • Typesimile: 630; 800; 1000; 1250 mm - 5th execution;
    • 400 ° C; 600 ° C - 120 minutes;
    • General industrial;
    • Corrosion-resistant;
    • Explosion-proof;
    • The family of duz - fans operating in common exhaust mode (in addition to the emergency response) are expanded;
    • Modification of fans with LDP;
    • Application of engines with increased efficiency at the request of IE2 or IE3

Van6-071 verse fans have an impeller working wheel or right rotation with a backbone of special-shaped blades, providing high efficiency and low noise.

Spiral housing - swivel. It is possible to work the fans in smoke mode (DF) and in combined smoke and ventilation mode (DV). In the latter case, the fans are equipped with engines for long-term permanent operation.

Fans are equipped with standard 3 phase asynchronous single-speed engines. For Van9 fans according to the 1st performance scheme, it is possible to equip the engines that allow frequency regulation Rotation speeds.

For the position of the housing P0 and LO for the 1st category of placement (street), protection against atmospheric precipitation umbrellas is provided (ordered separately as the option).

Climate, conditions Operation of the Vran6-071

Van6-071 verse fans should be installed outside the premises serviced and the limit of the constant stay zone.
Fans can be operated in moderate (y); Moderate and cold (UHL) and tropical (T) climate of the 1st and 2nd category of placement according to GOST 15150.

  • environmental temperature
    - from minus 45 to + 40 ° C for moderate climate,
    - from minus 60 to + 40 ° C for temperate and cold climate,
    - from minus 10 to + 50 ° C for tropical climate;
  • the average value of the vibration of external vibration sources in the fan installation places is not more than 2 mm / s.

Marking Vran-Doz

Aerodynamic characteristics of Vran-do



dimensions

Additional equipment on request

  • Thermo-noise insulating TSK casing
  • Soft COM-VRAN connector
  • Umbrella Protection
  • Cabinet Shsau.
  • Vibration insulators
  • Flange Reverse - FOOD - Background
  • Frequency converter
  • Smooth starter

We draw your attention to the fact that the offer is not a public offer. You can learn more on the page