A radial-type fans are belonging to the brand, which contains the wheels in their design with rebel. As a rule, they have a high efficiency, and during operation there is no discomfort from the noise of their motor. Van® trademark was first registered in 2008 and from that time it is considered a sample of comfort and modernity. Each fan is manufactured using the most recent technical developments, as well as the latest equipment. Cutting of all composite products (blades, wheels for wheels, housing walls) is performed using a laser. But the formation of details of conical and toroidal types is performed using a CNC controlled. In this case, welding wheels are carried out using a special welder robot.
Each body of the ventilation products is made of galvanized steel using sunset technology.
Since the production of fans is carried out on high-precision equipment, the serial products fully corresponds to the reference characteristics declared by the manufacturer. This guarantees constant high quality of each fan. Trademark Van® manufactures its products in 16 sizes, providing the widest choice of device performance, which is in the range of 300-120000 m3 / h, and the pressure indicator is about 2600 Pa.
As a rule, the fans from the Van are used in those systems where the functioning technology requires a high efficiency, low noise level, or a set of multiple fans that will work in parallel to each other. Such products have high technical parametersand can also completely replace the famous fan series domestic production (VC 4-70, BP 80-75, BP 86-77). It is over compared to them, the products of Vran have a number of advantages:
The main purpose of the fans Van
Fans can be installed in ventilation systems standard type, as well as in the air conditioning system and air heating Buildings in production or in residential premises. To travel during two hours gas-high mixesThe temperature of which is within 400-600 ° C, could not harm the fan, it is manufactured using special VANA® type versions) Du.
Fans are such types of versions:
Mechanism of fans from within
In its design, each fan has a impeller, which rotates both in and counterclockwise. Wheel blades have a special shape and bent slightly backwards. The spiral body of the device is also able to rotate. Fan mechanisms are manufactured both in the first and fifth structural scheme according to the adopted 5976 GOST standards.
The fans performed according to the first structural circuit, are directly connected to the engine and there are two modifications of the VANR6 type and vran9. They differ in the number of blades of their impeller.
Fans, which belong to the fifth structural pattern, in its design contain a belt type drive. Such products are only one version modification. Unlike it, Vran9, which belongs to the first constructive scheme, is equipped with engines, thanks to which you can perform a frequency of speed control.
For the climate execution devices of types U1, UHL1, T1 in the design of the mechanism is provided additional protection From atmospheric precipitation, which is equipped with a drive and exhaust part of the fan.
Fans that are used on large industrial enterprises, have a noise insulating casing, which makes it possible to largely reduce the noise level of the device to a value of 12 dB. In this case, the overall sound pressure level decreases by 25-30 dB at a distance of 5 meters.
If desired, the Customer may acquire additional components in the form of vibration insulators and flexible inserts that allow reduced dynamic loads. It will not be superfluous: reverse action flanges, frequency converters, and various devicesthat allow you to perform smooth start Fan.
Operational conditions
According to the operational rules and standards, so that the fans can serve their owner for many years, they must be installed outside the zone in which people are constantly being.
Products on the provisions of GOST 15150 are able to withstand a variety of climatic working conditions, ranging from moderate, and ending with a tropical climate.
Basic operating conditions:
the temperature around the device must match:
- "-" 45 - "+" 40 degrees Celsius for a moderate climate type;
- "-" 60 - "+" 40 degrees - for a moderately cold climate;
- "-" 10 - "+" 50 degrees - for tropics.
At the same time, the average value of the so-called vibrationability of all external mechanisms, which serve as a source of vibration oscillations, should be within 2 mm / s.
Overall and connecting dimensions of fans VRAN (1st version)
room fan | n. | n 1. | n 2. | n 3. | dimensions, mm | |||||||||||||
A. | A 1. | A 2. | B. | B 1. | B 2. | D. | d. | d 1. | t. | t 1. | L Max | L 1. | L 2. | |||||
VRAN-2,5 | 175 | 160 | 200 | 325 | 240 | 348 | 280 | M6 | 7 | 80 | 54 | 8 | 14 | 2 | 3 | 460 | 89 | 86 |
VRAN-2.8. | 199 | 200 | 222 | 362 | 300 | 383 | 310 | M6 | 7 | 100 | 41,5 | 8 | 14 | 2 | 3 | 480 | 101 | 101 |
VRAN-3,15 | 217 | 200 | 240 | 399 | 300 | 420 | 345 | M6 | 7 | 100 | 60 | 8 | 14 | 2 | 3 | 530 | 110 | 115 |
VRAN-3,55 | 249 | 200 | 272 | 454 | 400 | 475 | 390 | M6 | 7 | 100 | 37,5 | 8 | 16 | 2 | 4 | 580 | 127 | 129 |
VRAN-4. | 281 | 200 | 310 | 512 | 400 | 538 | 430 | M8. | 9 | 100 | 55 | 8 | 16 | 2 | 4 | 640 | 143 | 145 |
VRAN-4.5 | 318 | 240 | 350 | 574 | 480 | 604 | 480 | M8. | 9 | 120 | 55 | 8 | 16 | 2 | 4 | 770 | 160 | 164 |
VRAN-5. | 353 | 300 | 380 | 643 | 600 | 668 | 530 | M8. | 9 | 100 | 40 | 8 | 22 | 3 | 6 | 800 | 175 | 182 |
Vran-5,6 | 394 | 300 | 426 | 719 | 600 | 749 | 600 | M8. | 9 | 100 | 63 | 8 | 22 | 3 | 6 | 865 | 198 | 202 |
VRAN-6,3 | 441 | 400 | 470 | 801 | 700 | 830 | 660 | M8. | 9 | 100 | 35 | 8 | 26 | 4 | 7 | 975 | 222 | 231 |
VRAN-7,1 | 497 | 270 | 540 | 900 | 675 | 941 | 740 | M8. | 9 | 135 | 135 | 8 | 18 | 2 | 5 | 1030 | 250 | 260 |
VRAN-8. | 563 | 300 | 600 | 1009 | 750 | 1047 | 835 | M8. | 9 | 150 | 150 | 8 | 18 | 2 | 5 | 1135 | 282 | 297 |
VRAN-9. | 630 | 600 | 670 | 1132 | 1050 | 1170 | 940 | M8. | 9 | 150 | 35 | 16 | 26 | 4 | 7 | 1250 | 318 | 335 |
VRAN-10. | 703 | 450 | 750 | 1269 | 1050 | 1317 | 1050 | M8. | 12 | 150 | 150 | 16 | 24 | 3 | 7 | 1340 | 353 | 366 |
VRAN-11,2 | 784 | 750 | 830 | 1424 | 1350 | 1463 | 1170 | M10. | 12 | 150 | 40 | 16 | 32 | 5 | 9 | 1540 | 395 | 409 |
VRAN-12.6. | 877 | 750 | 925 | 1593 | 1500 | 1638 | 1285 | M10. | 12 | 150 | 87,5 | 16 | 34 | 5 | 10 | 1750 | 440 | 455 |
VRAN-14. | 980 | 672 | 1040 | 1460 | - | 1512 | - | - | 12 | 168 | - | - | 30 | 4 | 9 | 2150 | 594 | 980 |
room fan | Installation dimensions, mm | Flexible insert on the side: | ||||||||
C. | C 1 | C 2. | C 3. | C 4. | d 2. | k. | k 1. | digging | suction | |
VRAN-2.5 | 295 | 330 | 70 | - | - | 10 | 70 | - | VG-N-2.5 | VG-B-2.5 |
VRAN-2.8 | 295 | 365 | 80 | - | - | 10 | 75 | - | VG-N-2.8 | VG-B-2.8 |
VRAN-3.15 | 420 | 470 | 60 | - | - | 10 | 75 | - | VG-N-3,15 | VG-B-3.15 |
Van-3.55 | 460 | 530 | 104 | - | - | 10 | 90 | - | VG-N-3,55 | VG-B-3,55 |
VRAN-4. | 520 | 610 | 127 | - | - | 11 | 90 | - | VG-N-4 | VG-B-4 |
VRAN-4.5. | 525 | 660 | 140 | - | - | 12 | 100 | - | VG-N-4.5 | VG-B-4.5 |
VRAN-5. | 525 | 695 | 160 | - | - | 12 | 100 | - | VG-N-5 | VG-B-5 |
VRAN-5.6. | 550 | 740 | 183 | - | - | 14 | 110 | - | VG-N-5,6 | VG-B-5.6 |
VRAN-6.3. | 550 | 830 | 200 | - | - | 14 | 110 | - | VG-N-6.3 | VG-B-6.3 |
VRAN-7.1. | 710 | 750 | 200 | - | - | 14 | 125 | - | VG-N-7.1 | VG-B-7.1 |
VRAN-8. | 800 | 845 | 222 | - | - | 14 | 125 | - | VG-N-8 | Vg-B-8 |
VRAN-9. | 870 | 950 | 258 | - | - | 14 | 130 | 100 | VG-N-9 | VG-B-9 |
VRAN-10. | 960 | 960 | 218 | - | - | 14 | 130 | 245 | VG-N-10 | VG-B-10 |
VRAN-11.2. | 1070 | 1090 | 245 | - | - | 14 | 150 | 175 | VG-N-11.2 | VG-B-11.2 |
VRAN-12.5. | 1230 | 1200 | 235 | - | - | 16 | 180 | 105 | VG-N-12.5 | VG-B-12.5 |
VRAN-14. | 2250 | 1060 | 1485 | 530 | 915 | - | 395 | 473 | VG-N-14 | VG-B-14 |
Position of the body of the fan verso. No. 1.
room fan | Overall dimensions, mm | |||||||||||
0 0 | 45 0 | 90 0 | ||||||||||
B. | b. | H. | h. | B. | b. | H. | h. | B. | b. | H. | h. | |
Van No. 2.5 | 456 | 186 | 240 | 173 | 423 | 190 | 240 | 312 | 390 | 173 | 240 | 270 |
Van No. 2.8. | 515 | 213 | 310 | 193 | 471 | 206 | 310 | 349 | 441 | 193 | 310 | 302 |
Van No. 3,15 | 572 | 236 | 310 | 215 | 521 | 225 | 310 | 388 | 491 | 215 | 310 | 336 |
Van No. 3,55 | 644 | 267 | 350 | 245 | 590 | 256 | 350 | 438 | 557 | 245 | 350 | 377 |
Van No. 4. | 738 | 301 | 390 | 290 | 686 | 310 | 390 | 514 | 641 | 290 | 390 | 437 |
Van No. 4.5 | 831 | 338 | 435 | 325 | 761 | 339 | 435 | 570 | 719 | 325 | 435 | 483 |
Van No. 5. | 913 | 375 | 535 | 338 | 832 | 363 | 535 | 619 | 776 | 338 | 535 | 538 |
Van No. 5.6 | 1020 | 420 | 570 | 375 | 924 | 399 | 570 | 688 | 865 | 375 | 570 | 600 |
Van No. 6.3 | 1140 | 474 | 665 | 420 | 1034 | 442 | 665 | 768 | 973 | 420 | 665 | 667 |
Van No. 7,1 | 1282 | 534 | 745 | 480 | 1167 | 499 | 745 | 869 | 1103 | 480 | 745 | 748 |
Van No. 8. | 1440 | 602 | 795 | 536 | 1304 | 553 | 795 | 972 | 1238 | 536 | 795 | 839 |
Van No. 9. | 1615 | 677 | 890 | 590 | 1467 | 621 | 890 | 1078 | 1379 | 590 | 890 | 938 |
Van No. 10 | 1797 | 751 | 970 | 656 | 1627 | 689 | 970 | 1204 | 1533 | 656 | 970 | 1046 |
Van №11,2 | 2004 | 841 | 110 | 735 | 1822 | 764 | 1100 | 1342 | 1716 | 735 | 110 | 1163 |
Van No. 12.5 | 2235 | 947 | 1230 | 810 | 2050 | 869 | 1230 | 1487 | 1905 | 810 | 1230 | 1302 |
Van No. 14. | 2760 | 1170 | 1365 | 965 | - | - | - | - | 2350 | 965 | 1365 | 1590 |
room fan | Overall dimensions, mm | |||||||||||
135 0 | 270 0 | 315 0 | ||||||||||
B. | b. | H. | h. | B. | b. | H. | h. | B. | b. | H. | h. | |
Van No. 2.5 | 515 | 202 | 240 | 234 | 390 | 173 | 340 | 186 | 515 | 202 | 340 | 190 |
Van No. 2.8 | 579 | 230 | 310 | 265 | 441 | 193 | 350 | 213 | 579 | 230 | 350 | 206 |
Van No. 3.15 | 644 | 257 | 310 | 296 | 491 | 215 | 410 | 236 | 644 | 257 | 410 | 225 |
Van No. 3.55 | 728 | 290 | 350 | 335 | 557 | 245 | 450 | 267 | 728 | 290 | 450 | 256 |
Van No. 4. | 840 | 326 | 390 | 376 | 641 | 290 | 470 | 301 | 840 | 326 | 470 | 310 |
Van No. 4.5 | 936 | 366 | 435 | 422 | 719 | 325 | 535 | 338 | 936 | 366 | 535 | 339 |
Van No. 5. | 1023 | 404 | 535 | 470 | 776 | 338 | 580 | 375 | 1026 | 406 | 580 | 363 |
Van No. 5.6 | 1143 | 455 | 570 | 525 | 865 | 375 | 665 | 420 | 1143 | 455 | 665 | 399 |
Van No. 6.3 | 1282 | 513 | 665 | 591 | 973 | 420 | 746 | 474 | 1282 | 513 | 746 | 442 |
Van No. 7.1 | 1447 | 578 | 745 | 667 | 1103 | 480 | 845 | 534 | 1447 | 578 | 845 | 500 |
Van No. 8. | 1623 | 651 | 795 | 751 | 1238 | 536 | 895 | 602 | 1623 | 651 | 895 | 553 |
Van No. 9. | 1811 | 733 | 890 | 846 | 1379 | 590 | 1010 | 677 | 1811 | 733 | 1010 | 621 |
Van No. 10 | 2017 | 814 | 970 | 939 | 1533 | 656 | 1100 | 751 | 2017 | 814 | 1100 | 689 |
Van No. 11.2 | 2253 | 911 | 1100 | 1051 | 1716 | 735 | 1250 | 841 | 2254 | 911 | 1250 | 764 |
Van No. 12.5. | 2512 | 1025 | 1230 | 1181 | 1905 | 810 | 1430 | 947 | 2512 | 1025 | 1430 | 869 |
Van No. 14. | - | - | - | - | 2350 | 965 | 1635 | 1170 | - | - | - | - |
Overall and connecting dimensions of fans VRAN (5th execution)
№ fan | Connecting dimensions, mm | n. | n 1. | n 2. | n 3. | Overall dimensions, mm | ||||||||||||
BUT | A 1. | A 2. | IN | IN 1 | AT 2 | D. | d. | d 1. | t. | t 1. | L Max | L 1. | L 2. | |||||
6,3 | 441 | 400 | 470 | 801 | 700 | 830 | 660 | M8. | 9 | 100 | 35 | 8 | 26 | 4 | 7 | 1080 | 222 | 231 |
8 | 563 | 300 | 600 | 1009 | 750 | 1047 | 835 | M8. | 9 | 150 | 150 | 8 | 18 | 2 | 5 | 1200 | 282 | 297 |
10 | 703 | 450 | 750 | 1269 | 1050 | 1317 | 1050 | M8. | 12 | 150 | 150 | 16 | 24 | 3 | 7 | 1540 | 353 | 366 |
12,5 | 877 | 750 | 925 | 1523 | 1500 | 1638 | 1285 | M10. | 12 | 150 | 87,5 | 16 | 34 | 5 | 10 | 1710 | 440 | 455 |
№ fan | Installation dimensions, mm | Insert flexible on the side: | |||||||||
FROM | With 1. | With 2 | With 3. | d 2. | d 3. | to | to 1. | to 2. | digging | suction | |
6,3 | 980 | 1110 | 245 | - | 12 | 18 | 120 | 140 | 320 | VG-N-6.3 | VG-B-6.3 |
8 | 1156 | 1190 | 310 | - | 12 | 18 | 130 | 301 | 294 | VG-N-8 | Vg-B-8 |
10 | 1456 | 1900 | 446 | - | 12 | 18 | 150 | 381 | 904 | VG-N-10 | VG-B-10 |
12,5 | 1645 | 2025 | 550 | 2223 | 15 | 24 | 180 | 525 | 875 | VG-N-12.5 | VG-B-12.5 |
Position of the fan body Van scheme number 5
№ fan | Overall dimensions, mm | ||||||||||||||
0 0 | 45 0 | 90 0 | |||||||||||||
B. | B 1. | b. | H. | h. | B. | B 1. | b. | H. | h. | B. | B 1. | b. | H. | h. | |
6,3 | 1140 | 1736 | 474 | 671 | 426 | 1034 | 1662 | 442 | 671 | 768 | 973 | 1623 | 420 | 671 | 667 |
8 | 1440 | 1833 | 602 | 843 | 536 | 1304 | 1746 | 553 | 843 | 972 | 1238 | 1697 | 536 | 843 | 839 |
10 | 1797 | 2676 | 751 | 1050 | 656 | 1627 | 2568 | 689 | 1050 | 1204 | 1533 | 2507 | 656 | 1050 | 1046 |
12,5 | 2235 | 2918 | 947 | 1230 | 810 | 2050 | 2811 | 869 | 1230 | 1487 | 1905 | 2725 | 810 | 1230 | 1302 |
№ fan | Overall dimensions, mm | ||||||||||||||
135 0 | 270 0 | 315 0 | |||||||||||||
B. | B 1. | b. | H. | h. | B. | B 1. | b. | H. | h. | B. | B 1. | b. | H. | h. | |
6,3 | 1282 | 1583 | 513 | 671 | 591 | 973 | 1490 | 420 | 751 | 474 | 1282 | 1839 | 513 | 751 | 442 |
8 | 1623 | 1646 | 651 | 843 | 751 | 1238 | 1531 | 536 | 933 | 602 | 1623 | 1967 | 651 | 933 | 53 |
10 | 2017 | 2444 | 814 | 1050 | 939 | 1533 | 2286 | 656 | 1150 | 751 | 2017 | 2833 | 814 | 1150 | 689 |
12,5 | 2512 | 2655 | 1025 | 1230 | 1181 | 1905 | 2440 | 810 | 1430 | 947 | 2512 | 3117 | 1025 | 1430 | 869 |
Radial industrial fans Van medium pressure are presented in two modifications of working wheels and with a thick-dimensional range of R20 diameters of wheels. This allows you to choose the optimal model on any mode of operation. The performance of the fans is from 300 to 150000 m³ / h, the maximum pressure is 2600 Pa. The aggregates of this type are used in injection systems and installations, where there are limitations on dimensions. Specifications Fans Van are not inferior to the indicators of imported analogs. The strength indicators are confirmed by appropriate tests.
Van fans are installed in standard ventilation, air conditioning and air heating systems, the aggregates are suitable for production or residential premises. Especially effective in installations where there are hard restrictions on the overall dimensions of the fan. Suitable for copper ventilation.
The following versions of this model are presented:
The main element of the fan design is the impeller with blades, bent back. The wheel is placed in a rotary spiral case. The inlet nozzle of a special cylindrical shape is placed outside the wheel, which ensures durability. The input flange is also not provided, due to which the air inlet on the suction side is more favorable. To protect the engine from atmospheric precipitation there is a separate mechanism. Engine three-phase asynchronous single-speed. Models Vran9 on the 1st scheme can be equipped with a drive with frequency control of the speed of rotation. Fans are able to operate in smoke mode or in the combined smoke and ventilation mode - in such models installed engines for a long continuous operation.
Industrial fans are installed outside the premises on the distance from the places of permanent stay of people. Operation is allowed in a moderate, moderately cold and tropical climate when placing 1 and 2 categories. Permissible air temperature - from -45 to + 50ºС. If there is a source of vibration nearby, the vibration rate should not exceed 2 mm / s. To reduce the noise level, you can use a noise insulating casing.
The manufacturer offers the following versal fan options:
Vintinform provides deliveries ventilation equipment To all regions of Russia. We offer Vran6 fans and breaks the following sizes:
Among the partners "Ventenform" - leading domestic and foreign manufacturers of ventilation equipment, which guarantees high quality products. We offer our customers best prices And the most convenient conditions for purchase.
Plant Web is the largest manufacturer of ventilation equipment in Russia, including such a product as a centrifugal fan of general industrial purpose. The centrifugal fan of the BP-80-75 series or VRAN is the original verse name, the VC-14-46 or is used in the ventilation systems, air conditioning and air heating of various destinations.
Radial fans of Vran-Doo and the roofing fans are installed in special exhaust ventilation systems to remove gases occurring during fire and simultaneously removing heat outside the room. At the same time, the localization of the fire zone is ensured and the possibility of carrying out work to combat fire and to rescue people and equipment is being created. Installations can move gas-air mixtures with a temperature of 400 ° C and 600 ° C for at least 120 minutes.
Centrifugal fan BP-80-75 - replacement for fan Van at the request of the buyer.
Fans Vran. low pressure Made in the general industrial, heat resistant, corrosion-resistant, north and explosion-proof performance. Operating wheels of such a fan contain 9 or 6 curved vanes back. Due to the wide size of the working wheels, the centrifugal fan is very tightly closed the operating points in the main ventilation tasks.
A centrifugal fan is made by 1st (with a direct connection with the engine) and on the 5th (with belt drive) constructive design schemes. Performance from 1000 m³ / h to 100,000 m³ / h, full pressure from 100 Pa to 1800 Pa.
The centrifugal fan is applied in systems where high efficiency is required, low noise level and in systems with parallel operation of several fans.
Low Pressure Fans Vran6 and Vran9 serve to move gas and steam-air mixtures to which explosive can be attributed. Installations are used in stationary ventilation and air conditioning systems, as well as in air heating systems for public, industrial and residential buildings, as well as in industrial and sanitary purposes.
reduced installation power on the fan;
reduced dimensions and weight;
used new technology manufacture of galvanized steel housing;
additional options for the use of flexible rates and vibration insulators are proposed;
new, more thick, adopted in the world is a si-dimensional R20 series;
an outlet is increased in accordance with European standards.
Vran-do fan It has an impeller of the left or right rotation with bent back by the blades of a special form, providing high efficiency and low noise. Spiral housing - swivel. According to the design scheme 1 (with a direct connection with the engine), all sizes of fans are made. According to a design scheme of execution 5 (with belt drive), fans No. 4 are made; five; 6.3; eight; 10 and 12.5.
The operating wheels of the fans are made of steel ST3 (for temperature to 400 ° C) and from steel 12x18H10T (for temperature to 600 ° C) with paint and varnish heat-resistant coating. The thermal protection of bearing nodes ensures reliable operation of the fan when moving hot gases.
Vran-Du fans for ventilation systems are installed in special inlet systems Smoke removal for creating overpressure (Puzzle) in staircases, tambura gateways and mines of buildings elevators to prevent smoke penetration into these rooms and create the ability to perform fire combat and to save people and equipment.
VROR-DU 6.3 fans are installed in special exhaust systems to remove gases occurring during the fire and at the same time removal of heat outside the room, can move gas-air mixtures with a temperature of up to 400 ° C and up to 600 ° C for at least 120 minutes. At the same time, the localization of the fire zone is ensured and the possibility of carrying out work to combat fire and to rescue people and equipment is being created.
According to the 1st structural scheme, fans of sizes are made: 5; 6.3; eight.
On the 5th structural scheme, sizes fans are made: 6.3; eight; 10; 12.5.
general industrial (H)
corrosion-resistant (K1)
Explosion-proof (c) - only on the 1st constructive scheme
Explosion-proof corrosion-resistant (VK1) - only on the 1st constructive scheme
VRAN-DU fans 6.3 have an impeller working wheel of a drum type of left or right rotation with 32 bent forward with the blades. Spiral housing - swivel. He has an entrance nozzle cylindrical shape and not included in the impeller, which ensures reliable operation of the fan when high temperatures Movement medium.
Execution of VROR-DB 6.3 fans in a noise-insulating casing (manufactured for general industrial design and positions of the housings 0 and 90 degrees) reduces the total sound power, emitted by a fan by 12DB, due to the noise-absorbing and noise insulating properties of the casing. The total sound pressure level is reduced by 25 ... 30 DB at a distance of 5m.
An additional equipment is proposed with vibration and inserts and flexible inserts, which reduces dynamic loads, as well as flanges inverse and automation cabinet.
Fans should be installed outside the served room and the limit of the constant stay zone.
Fans can be operated in moderate (y); Moderate and cold (UHL) and tropical (T) climate of the 1st and 2nd category of placement according to GOST 15150.
environmental temperature
from minus 45 to + 40 ° C for temperate climate
from minus 60 to + 40 ° C for temperate and cold climate,
from minus 10 to + 50 ° C for tropical climate;
the average value of the vibration of external vibration sources in the fan installation places is not more than 2 mm / s;
Fans are certified and have permission to use on explosive and chemically hazardous industries and objects.
Van6-071 verse fans have an impeller working wheel or right rotation with a backbone of special-shaped blades, providing high efficiency and low noise.
Spiral housing - swivel. It is possible to work the fans in smoke mode (DF) and in combined smoke and ventilation mode (DV). In the latter case, the fans are equipped with engines for long-term permanent operation.
Fans are equipped with standard 3 phase asynchronous single-speed engines. For Van9 fans according to the 1st performance scheme, it is possible to equip the engines that allow frequency regulation Rotation speeds.
For the position of the housing P0 and LO for the 1st category of placement (street), protection against atmospheric precipitation umbrellas is provided (ordered separately as the option).
Van6-071 verse fans should be installed outside the premises serviced and the limit of the constant stay zone.
Fans can be operated in moderate (y); Moderate and cold (UHL) and tropical (T) climate of the 1st and 2nd category of placement according to GOST 15150.
We draw your attention to the fact that the offer is not a public offer. You can learn more on the page