» Roof intake installations. Roof Babeless Orion Top Conditioners

Roof intake installations. Roof Babeless Orion Top Conditioners

Air Conditioners Roof Cegless Intakt Pro are an advanced line of supply and exhaust recovery installations of outdoor versions intended for mounting on the roofs of buildings. The location category corresponds to U1 (ordinary and insulated valves) and UHL1 (North valves) according to GOST 15150-69.

Installations are designed for rooms with high ceilings and large open spaces, for example:

Roof beamless air conditioners are an innovative product on the market. ventilation equipment. To create this series were used modern technologies, the latest design decisions and many years of experience, which made it possible to get a whole range of advantages.

Advantages of using INTAKT PRO air conditioners:

  • dual EC fans provide low noise and power consumption;
  • the built-in plate heat recovery ensures the utilization of the heat of exhaust air and saving the thermal energy of the carrier;
  • to improve the energy efficiency of the installation, it provides a mixing chamber that utilizes both explicit warmth and hidden;
  • there is no need to organize a ventilation chamber, which allows to significantly increase the useful space of the building;
  • there is no need to design, acquisition and installation: air ducts, ventilation lattices and diffusers, insulating materials, consumable assembly materials, which leads to a decrease in capital expenditures on engineering equipment building;
  • this system is sufficient to be sufficient: electrical pipelines, heat pipelines and pipelines of the cooling system;
  • it is possible to resolve the system of air conditioning system by simply dividing the area of \u200b\u200bthe room to the processed area of \u200b\u200bthe selected sizes of Intakt Pro;
  • the vortex adjustable air distributor, depending on the operation mode, can change the shape of the air jet. The unique design allows you to supply air into the work area of \u200b\u200bthe room at any period of the year without the risk of reducing the comfortable stay of people indoors.

Air jet formation modes

Heating mode. The temperature of the air supplied above the air temperature in the room. Consequently, the air, camshable, rises up. The greater the difference in the temperatures of the supply air and air indoors, the less twisted should be to ensure optimal range and air supply directly into the working area.

Isothermal mode. The temperature of the supplied air is equal to the air temperature.

Cooling mode. The temperature of the supplied air is below the room temperature in the room. Air is distributed in the horizontal direction parallel to the ceiling. Having trollenged, the air is lowered down - into the working area, without creating the feeling of drafts.

At the location of the INTAKT Pro aggregates, it is necessary to exclude the possibility of entering the emissions from one unit to the fence of another unit. To do this, you need to send exhaust lattices of the aggregates on each other. The exhaust grille should not cut anything to ensure effective removal Air from the room. To maintain heat exchangers, it is necessary to leave free space from the side removable panelsThe panels are fully removed, do not have a loop, so it is necessary to maintain a minimum of space. Inflow aerial jet Must be supplied to the working area completely unhindered, so when the aggregates are arranged, the absence of any obstacles in the area of \u200b\u200bdirect air distribution should be provided. Installations are kept on the mounting frame due to their own weight. Silicone, polyurethane foam or a similar substance are needed for sealing. The filtering insert on the exhaust part is replaced through the outer module (pulls up).

Main technical characteristics

ParameterUnit.INTAKT 90.INTAKT 60.
Nominal air flow m3 / C. 9000 6000
Nominal power consumption kw 7 4
Minimum Maximum Minimum Maximum
Installation height (minimum equipment - only recovery) m. 5 25 4 25
Mounting height (maximum equipment - recovery, noiselessness, heating, cooling) m. 11 11
Distance from the center of the aggregate to the walls m. 6,5 14 5,5 11
Distance between the centers of the aggregates m. 13 28 11 22
Maximum processed area m2. 700 450
Basic vortex distributor /Lsa.i80. /Lsa.i63.

Overall drawing and specification of the roof chamberless air conditioner INTAKT PRO in full configuration

  1. Protective roof against precipitation.
  2. Protective visor on suction (on request with a drip) and exhaust.
  3. Air valves on suction and exhaust. At the outdoor temperature below -25 ° C, it is recommended to install insulated valves. At temperatures below -45 ° C, it is recommended to install North valves.
  4. Filter pocket class G4 air supply air.
  5. Recuperator plate with bypass air valve in case of recuperator frost.
  6. Drift with pallet and drainage system.
  7. Fans of inflows and exhaust, dual, with highly efficient EU engines.
  8. Air valve recycling system.
  9. Filter pocket class G4 exhaust air.
  10. The noiselessness of the supply stream is installed on request.
  11. Drainage system (connected to drainage system external module) with condensate plum pipe.
  12. Water / HW heater.
  13. Water / CW cooler. or freon / CF. with a drip, or a drop-dealer separately /as.1.
  14. Vortex adjustable air distributor / LSA. (For heating / cooling modes), or nozzle /LCN.1 (only for heating mode).

Elements internal block and climatic block are options. The composition of these blocks must be selected depending on the operating conditions. The composition of the outer block cannot be changed.

  • The external module / butt.e1 includes devices from 1 to 8.
  • The internal module without silencer /oat.i1 includes devices 9, 11.
  • The internal module with the silencer /oat.i2 includes devices 9, 10, 11.
Dimensional weight characteristics INTAKT 90.INTAKT 60.
A, mm. B, mm. L, mm. Mass, kg. A, mm. B, mm. L, mm. Mass, kg.
External module
External module Oat.e1 1400 2000 1700 550 1200 1600 1400 420
Internal module
Internal module without silencer Oat.i1 1100 1100 1800 170 900 900 1800 145
Internal module with silencer Oat.i2. 1100 1100 1800 210 900 900 1800 175
Climate module
Water heater HW.2. 1100 1100 300 46 900 900 300 35
Water heater HW.3. 1100 1100 300 54 900 900 300 38
CW.3 1100 1100 550 64 900 900 550 49
Water cooler with a drip CW.4. 1100 1100 550 70 900 900 550 54
CF.3. 1100 1100 550 64 900 900 550 49
Freon cooler with a drip CF.4. 1100 1100 550 70 900 900 550 54
Drainage AS.1 1100 1100 400 41 900 900 400 32
Air distributor
Vortex adjustable LSA. 1300 1300 560 35 1100 1100 400 27
Nozzle LCN.1. 1100 1100 300 18 900 900 300 14

Important note: Paragraph 10.5 SNiP 41-01-2003 "Emissions into the atmosphere from the ventilation systems of industrial premises should be placed by calculation or at a distance from receiving devices for outside air at least 10 m horizontally or 6 m vertically at a horizontal distance less than 10 M "refers to industrial premises with harmful emissions, does not apply to non-industrial premises. The placement of the INTAKT Pro aggregates "Influx to the influx", "extract to the hood" eliminates the increasing air in the trimming.

Roofing conditioners Boxing Production of a mustache perform various air processing functions and are designed to create and support decentralized second ventilation. Air conditioners from this line are produced by four sizes with air production capacity up to 13 thousand m3 / h, can be applied on any objects, both in civil and industrial.

A wide range of options for performing air conditioners box, as well as various configurations, among which you can pick up optimal option easily. The variety of execution options makes it possible to apply these air conditioners both as a supply, exhaust, supply and exhaust systems, and as installations that provide heating and air cooling. Boxing installations are equipped with a high-quality automatic control system that allows you to follow the exact microclimate parameters on the object and makes the use of central air conditioners more economical and efficient.

Roof Boxing Conditioners - Features and Benefits

All roof air conditioners box consist of two key elements - external and internal blocks. The external unit is mounted on the roof (comes with a roof cover, selected under the type of roof) and is frame design from reliable and strong materials. The base of the casing - the galvanized steel panels filled with polyurethane foam. The panels provide good heat insulation and reduce its losses to the minimum possible number.

External blocks are also equipped with convenient service panels that are sealed and can be dismantled for repair and maintenance in the minimum time. The external unit usually includes such elements:


  • Air-acting, exhaust, recycling valves;
  • Fans;
  • Filters of varying degrees of cleaning;
  • Warm utilizers.

The internal unit works with air coming directly from the room. He serves it and takes it, providing a permanent and high-quality exchange. In the inner block there is a heat exchanger, an air distributor, a response element for an air duct or an air distribution grille. Since the heat exchanger is mounted inside this block, in winter freezing, you can not be afraid and operate the air conditioner even with serious frosts. In addition, if desired, the air conditioner is possible through the internal unit to complete the separate air cooler.

The Smart Treding company offers a wide selection of roof air conditioners boxing, among which you can pick up right size With the necessary performance by air, and the package that ensures the creation and maintenance of the required air parameters. At the moment, thanks to the design involving the location of the main block on the roof, and due to this space-saving space, it is really the optimal option for most objects. The managers of our company will help you choose and calculate the root air conditioner box for specific working conditions in a given room.

Air Conditioners Roof Changless LM Pro Orion Top is an advanced line of supply and exhaust recovery installations of outdoor versions intended for mounting on the roofs of buildings.
Roof beamless air conditioners are an innovative product on the ventilation equipment market. To create this series, modern technologies were used, the latest design solutions and many years of experience, which made it possible to receive a whole range of advantages.

The vortex adjustable air distributor, depending on the operation mode, can change the shape of the air jet.

Heating mode

The temperature of the air supplied above the air temperature in the room. Consequently, the air, camshable, rises up. The greater the difference between the temperatures of the supply air and air indoors, the less twisted should be to ensure optimal range and air supply directly into the working area

Isothermal mode

The temperature of the supplied air is equal to the air temperature.

Cooling mode

The temperature of the supplied air is below the room temperature in the room. Air is distributed in the horizontal direction parallel to the ceiling. Having trollenged, the air is lowered down - into the working area, without creating the feeling of drafts.

Designed for operation on large objects with large open spaces and high ceilings - production facilities, warehouses, shopping centers, stadiums, etc. The aggregates are mounted in the roof of the building and prepare the supply air and its distribution directly into the working area, as well as the removal of exhaust air with the possibility of partial or complete recycling.

  • Dual fans with a "free" wheel provide minimal power consumption and noise, as well as a redundancy of 50% due to parallel independent operation of two fans.
  • The built-in plate recovery ensures the utilization of the heat of exhaust air.
  • Adjustable vortex diffuser allows us to provide an optimal airflow structure depending on the temperature of the supplied air and the desired design solution.
  • Heated air valve (optional) allow you to start and operating the unit at an outdoor temperature to -40 ° C (without this option to -25 ° C).

Modes of operation:

  1. influx and exhaust, without recycling;
  2. independent influx or exhaust;
  3. influx and exhaust, with partial recycling;
  4. recycling 100%.

Main technical characteristics

Elements of the indoor unit and climatic block are options. The composition of these blocks must be selected depending on the operating conditions. The composition of the outer block cannot be changed.

  • The external module / butt.e1 includes devices from 1 to 8.
  • The internal module without silencer /oat.i1 includes devices 9, 11.
  • The internal module with the silencer /oat.i2 includes devices 9, 10, 11.