On this page you can find and download automation instructions, regulators, modules, thermostats, ... Danfoss in PDF format.
RA-N and RA-NCX regulating valves are designed for use in two-pipe pumping systems Water heating. 2009 | Language: RU | PDF 1.27 MB.
The Danfoss Series PFM 5000 Standard series is designed to measure pressure drop, flow and temperature, for hydraulic balancing of heat and cold supply systems. User's manual. Language: RU | PDF 887.60 KB.
AME 55 QM Series Danfoss Reducer Electric Drives. Technical description. Language: RU | PDF 136.45 Kb.
AMI 140 Danfoss series electric drives for a two-position control. Technical description. Language: RU | PDF 1.10 MB.
Reducer electric drives Danfoss AMV 110 NL, AMV 120 NL. Technical description. Language: RU | PDF 122.06 Kb.
The thermostatic element of the Danfoss Qt series is the reverse coolant temperature controller when used with AB-QM valve. Technical description. Language: RU | PDF 1.29 MB.
Automated information measuring system Comfort Contour. Danfoss brochure. Language: RU | PDF 4.65 MB.
Danfoss Controllers ECA Connect Series. Passport. Language: RU | PDF 361.34 KB.
Thermoelectric Drives Danfoss ABNM Series (normally closed) with analog control. Technical description. Language: RU | PDF 327.77 KB.
Thermoelectric drives Danfoss series ABV. Technical description. Language: RU | PDF 138.87 KB.
Reductor electric drives Danfoss AMV 162/182 series (230 V) for rotary control valves. Installation instructions. Language: RU | PDF 1.34 MB.
Ame 10 - EI96L11F series Danfoss electric drives. User's manual. Language: EN, DE, IT, PL, FR, ES | PDF 799.92 KB.
Reducer electric drives DANFOSS AME 15 series (ES), AME 16, AME 25, AME 35. Technical description. Language: RU | PDF 605.78 KB.
Reducer electric drives Danfoss Ame 85 series, AME 86. Technical description. Language: RU | PDF 487.78 KB.
Ame 130, AME 140, AME 130H, AME 140H, AME 130, AME 140H gearboxes. Technical description. Language: RU | PDF 864.29 KB.
Reducer electric drives Danfoss AMV Series 435. Technical Description. Language: RU | PDF 930.12 KB.
Reducer electric drives DANFOSS AMV 438SU series (with a return spring). Technical description. Language: RU | PDF 687.15 Kb.
Thermoelectric drives Danfoss TWA series. Technical description. Language: RU | PDF 285.27 KB.
Embedded input / output units Danfoss ECA 32 Series for ECL COMFORT 310 / 310B controllers. Technical description. Language: RU | PDF 757.87 KB.
Danfoss Temperature Controllers ECL Series Comfort 110 for Heating and Hot Water Supply Systems (DHW). Technical description. Language: RU | PDF 767.25 Kb.
Universal Danfoss Temperature Controllers Series ECL Comfort 210/210 V and ECA Remote Control Unit 30. Technical Description. Language: RU | PDF 1.16 MB.
Universal Danfoss Temperature Controllers of the ECL Comfort 310/310 V Series and ECA Remote Control Unit 30. Technical Description. Language: RU | PDF 1.25 MB.
Programming keys Danfoss series A214, A314 for ECL temperature regulators Comfort 210/310. Operating instructions. Language: RU | PDF 5.56 MB.
The electronic key of the Danfoss application A217, A317 series for ECL Comfort 210/310 temperature regulators. Instructions for use. Language: RU | PDF 4.08 MB.
A230 Series Danfoss Programming Keys for ECL Comfort 210/310 Temperature Regulators. Operating Instructions. Language: RU | PDF 2.43 MB.
DANFOSS A231, A331 Series Programming Keys for ECL Comfort 210/310 Temperature Regulators. Operating Instructions. Language: RU | PDF 3.16 MB.
A260 Series Danfoss Programming Keys for ECL Comfort 210 Temperature Regulators. Operating Instructions. Language: RU | PDF 2.02 MB.
A266 series Danfoss programming keys for ECL Comfort 210/310 temperature regulators. Operating instructions. Language: RU | PDF 3.52 MB.
A275, A375 Series Danfoss Programming Keys for ECL Comfort 210/310 Temperature Regulators. Operating Instructions. Language: RU | PDF 6.43 MB.
A275, A375 Series Danfoss Programming Keys for ECL Comfort 210/310 Temperature Regulators. Installation Instructions. Language: RU | PDF 3.05 MB.
A361 Series Danfoss Programming Keys for ECL Comfort 310 Temperature Regulators. Operating Instructions. Language: RU | PDF 2.92 MB.
A361 Series Danfoss Programming Keys for ECL Comfort 310 Temperature Regulators. Installation Instructions. Language: RU | PDF 1.34 MB.
A368 Series Danfoss Programming Keys for ECL Comfort 310 Temperature Regulators. Operating Instructions. Language: RU | PDF 3.08 MB.
A368 Series Danfoss Programming Keys for ECL Comfort 310 Temperature Regulators. Installation instructions. Language: RU | PDF 3.64 MB.
A376 Danfoss Programming Keys for ECL Comfort 310 Temperature Regulators. Operating Instructions. Language: RU | PDF 5.06 MB.
A376 series Danfoss programming keys for ECL Comfort 310 temperature regulators. Installation instructions. Language: RU | PDF 2.31 MB.
Communication capabilities of Danfoss temperature regulators ECL COMFORT 210/310 series. Operating instructions. Language: RU | PDF 673.15 Kb.
OPC server for Danfoss temperature regulators ECL COMFORT 310 series. Operating instructions. Language: RU | PDF 999.75 Kb.
USB driver. Connecting the ECL Comfort 210/310 temperature regulators to the PC. Installation instructions. Language: RU | PDF 223.44 Kb.
New Danfoss ECL COMFORT 210/310 controllers are extended functionality and maximum efficiency. Brochure. Language: RU | PDF 2.97 MB.
Danfoss Temperature Controllers Series ECL Comfort 210/310. User Guide. Language: RU | PDF 3.85 MB.
Selection of ECL keys. User's manual. Language: RU | PDF 267.81 KB.
Selection of ECL keys. User's manual. Translation table with codes. Language: RU | PDF 18.62 KB.
Switching panel Danfoss series FH-WC to control systems outdoor heating. Technical description. Language: RU, EN, DE, IT, FR | PDF 85.25 Kb.
Danfoss Switching Panel FH-WC (230V) Series to control outdoor heating systems. Installation instructions. Language: RU, EN, DE, IT, FR | PDF 2.37 MB.
Cabinet with an apartment joining an apartment heating system-1-B1 (ShKSO-1-B1). Technical description. Language: RU | PDF 1.18 MB.
Wardrobe with an apartment joining the heating system-1-B4, B7 (ShKSO-1-B4, B7). Technical description. Language: RU | PDF 1.24 MB.
Cabinet with an apartment joining an apartment heating system of ShKSO-1 B1 to connect one apartment. Instructions for maintenance. Language: RU | PDF 1.28 MB.
Cabinet with an apartment joining an apartment heating system of ShKSO-1 B1 to connect one apartment. Installation instructions. Language: RU | PDF 1.04 MB.
Apartment heat meters Danfoss M-Cal Compact series (Modification 447). Passport. Language: RU | PDF 241.12 KB.
Apartment heat meters Danfoss M-Cal Compact series (Modification 447). Brochure. Language: RU | PDF 246.47 KB.
Apartment heat meters Danfoss M-CAL MS series. Passport. Language: RU | PDF 498.30 KB.
Apartment heat meters Danfoss M-CAL MS series. Technical description. Language: RU | PDF 202.01 KB.
Apartment heat meters Danfoss M-CAL Series MS for measuring, processing and presenting the current and archive information about the number of thermal energy consumed, the temperature, the flow rate of the coolant and the concomitant data in closed systems Water heating of individual consumers (consumers' consumers). Information booklet. Language: RU | PDF 444.39 KB.
Apartment heat meters Danfoss Series Sonometer 500. Passport. Language: RU | PDF 293.87 KB.
Ultrasonic apartment heat meters Danfoss Series Sonometer 500 for measuring, processing and presenting current and archival information about the amount of thermal energy consumed, temperature, coolant consumption and other data in closed water heating systems of individual consumers (apartments, cottages, office space). Information booklet. Language: RU | PDF 394.82 KB.
Ultrasonic apartment heat meters Danfoss Series Sonometer 1100 for measuring, processing and presenting current and archival information about the amount of thermal energy consumed, temperature, coolant consumption and other data in closed water heating systems of individual consumers (apartments, cottages, office space). Information booklet. Language: RU, EN | PDF 242.78 KB.
Ultrasonic apartment heat meters Danfoss Series Sonometer 1100. Passport. Language: RU, EN | PDF 1.23 MB.
Remote controller MBUS id \u003d 0x2f for apartment heat meters Danfoss Series Sonometer 1100. Instructions for use. Language: RU, EN | PDF 1.70 MB.
Apartment heat meters Danfoss Series Sonometer 1000. Passport. Language: RU, EN | PDF 1.68 MB.
Ultrasonic Sono 1500 CT flow meter for measuring the flow and volume of various liquids at utility facilities and in other industries in technological and accounting and calculated operations. Passport. Language: RU | PDF 400.05 Kb.
Thermal SPT 943 for measuring and taking into account thermal energy and the amount of heat carrier in closed and open water supply water systems. User's manual. Language: RU | PDF 607.48 Kb.
Danfoss Pulse Signal Converters Hydro Port Pulse Series To connect to M-BUS network of resource accounting devices with a pulse output. Passport. Language: RU | PDF 300.96 KB.
Danfoss Hydro Port Pulse Pulse Signals Pulse Signals. Technical description. Language: RU | PDF 139.01 KB.
Izar Port Pulse Mini Pulse Mini Pulse Signals Converters. Passport. Language: RU | PDF 252.97 KB.
Izar Port Pulse Mini Pulse Mini Pulse Signals Converters. Technical description. Language: RU | PDF 128.78 KB.
DANFOSS DANFOSS COMPUTERS, IZAR CENTER MEMORY - M-BUS signals converters. Passport. Language: RU | PDF 360.97 KB.
Danfoss Danfoss Series Center Series, Izar Center Memory 60, 120, 250 - M-BUS Signal Converters. Technical description. Language: RU | PDF 277.00 Kb.
Dispatch system individual accounting Thermal energy M-BUS. Technical information for designers, installers, engineers selling. Language: RU | PDF 727.36 Kb.
Radiator counters - Danfoss distributors of the Indiv-3, Indiv-3R, Indiv-3R2, INDIV-3RD series. Passport. Language: RU | PDF 460.78 KB.
Radiator distributors The heat of Indiv-3 for organizing quarterly heat metering in residential buildings with a vertical wiring of the heating system. Information booklet. Language: RU | PDF 486.92 KB.
Danfoss Pulse Adapter Indiv Pad Series. Technical description. Language: RU | PDF 253.81 KB.
Indiv RM Radio Set for Personal Computer. Technical description. Language: RU | PDF 198.32 Kb.
Network nodes NNV- and NNB-. Installation and operation instructions. Language: RU | PDF 515.57 KB.
Individual Energy Directorate Danfoss AMR Series AMR series with remote wireless reading instrument readings. Installation and operation instructions. Language: RU | PDF 647.70 KB.
Danfoss Pulse Adapter Indiv Pad Series. Passport. Language: RU | PDF 338.95 Kb.
Network nodes Danfoss series NNB, NNV. Passport. Language: RU | PDF 335.04 KB.
Designing an Indiv AMR system. Information booklet. Language: RU | PDF 5.70 MB.
Danfoss electronic devices of the IndiV-5, Indiv-5R, Indiv-5R-1 series for thermal energy distribution. Passport. Language: RU | PDF 282.60 KB.
Installation of meters - Danfoss heat distributors of the Indiv-5 series (5R) on bimetallic radiators. Installation instructions. Language: RU | PDF 1.16 MB.
Installation of meters - heat distributors Danfoss series Indiv-5 (5R) on cast-iron sectional radiators. Installation instructions. Language: RU | PDF 908.17 Kb.
Installing meters - Danfoss heat distributors of the Indiv-5 series, Indiv-5R on the Accord Convectors. Installation instructions. Language: RU | PDF 1.01 MB.
Installation of meters - Danfoss heat distributors of the Indiv-5 series, Indiv-5R on the "Universal" convectors with a welded bracket. Installation instructions. Language: RU | PDF 2.54 MB.
Installation of meters - Danfoss heat distributors of the Indiv-5 series, Indiv-5R on the "Universal" convectors with a straight valve. Installation instructions. Language: RU | PDF 3.03 MB.
Installation of meters - Danfoss heat distributors of the Indiv-5, Indiv-5R series at the Universal Convectors with the U-Bend valve. Installation instructions. Language: RU | PDF 3.01 MB.
Installing counters - Danfoss heat distributors of the Indiv-5 series (5R) on panel radiators. Installation instructions. Language: RU | PDF 906.56 Kb.
Danfoss Radiator Distributors of the Indiv series (modifications Indiv-5, Indiv-5R). Information booklet. Language: RU | PDF 1.02 MB.
Danfoss Radiator Distributions Series Indiv-5, Indiv-5R. User's manual. Language: RU | PDF 122.73 Kb.
Pressure regulators "to ourselves" Danfoss series AVA (PN 25 / DN 15 - 50). Installation and operation instructions. Language: RU, EN, DE, IT, FR, ES | PDF 1.70 MB.
Pressure regulators "to ourselves" Danfoss AVA-AVDS series. Service kits. Installation instructions. Language: RU, EN, DE, IT, FR, ES | PDF 4.76 MB.
Valves - pressure regulators "to ourselves" Danfoss AVA series (RU 25). Technical description. Language: RU, EN, DE, IT, FR, ES | PDF 591.49 KB.
Pressure regulators "After" Danfoss AVD series, AVDS - PN 16, 25 / DN 15 - 50. Installation and operation instructions. Language: RU, EN, DE, IT, FR, ES | PDF 2.62 MB.
Valves - pressure regulators "After" Danfoss AVD series - for water, AVDS - for steam (RU 25). Technical description. Language: RU, EN, DE, IT, FR, ES | PDF 1.02 MB.
Valves - pressure regulators "to ourselves" Danfoss AVDO series. Technical description. Language: RU | PDF 721.33 KB.
Control regulators Danfoss AVDO2 series. Installation and operation instructions. Language: RU | PDF 698.14 KB.
Pressure regulators "to ourselves" Danfoss AVDO series. User's manual. Language: RU | PDF 827.43 Kb.
Valves - Delta Regulators danfoss pressures AVP series - with variable setting for the feed and return pipeline; AVP-F - with fixed tuning for the return pipeline (RU16). Technical description. Language: RU, EN | PDF 2.44 MB.
Danfoss Pressure Delta Regulators AVP Series, AVP-F. Accessories SP AV. Installation instructions. Language: RU, EN | PDF 739.51 KB.
Danfoss Pressure Delta Regulators AVP Series, AVP-F (SP AV PN 16). Service kits. Installation and operation instructions. Language: RU, EN | PDF 1.42 MB.
Danfoss Pressure Delta Regulators AVP Series, AVP-F (PN 16,25 / DN 15 - 50). Installation and operation instructions. Language: RU, EN | PDF 2.11 Mb.
Danfoss Pressure Delta Regulators AVP series, AVP-F (SP AV PN 25). Service kits. Installation and operation instructions. Language: RU, EN | PDF 1.79 MB.
Danfoss Pressure Delta Regulators AVP Series, AVP-F. Accessories. Installation and operation instructions. Language: RU, EN | PDF 748.53 KB.
Valves - pressure drop controls Danfoss AVP series - with variable adjustment for the feed and return pipe; AVP-F - with fixed tuning for the return pipeline (RU 25). Technical description. Language: RU, EN | PDF 1.21 MB.
Danfoss temperature regulators AVTB series. Technical description. Language: RU | PDF 776.24 KB.
Danfoss Danfoss AVTB Series Temperature Controllers. Installation instructions. Language: RU | PDF 1.63 MB.
Danfoss Temperature Controllers AVTB Series, Sensor Ø9.5 / 180 mm. User's manual. Language: RU | PDF 80.08 KB.
Danfoss temperature regulators AVTB series. Installation instructions. Language: RU | PDF 655.69 KB.
Temperature regulators RAVK / RAV8 (VMT8, VMA, VMV) of direct action for applying hot water systems of small buildings (cottages). Technical description. Language: RU | PDF 1.09 MB.
Temperature regulators RAVK (25-45 ° C). Installation and operation instructions. Language: RU | PDF 1.48 MB.
Temperature regulators RAVK (25-65 ° C). Installation and operation instructions. Language: RU | PDF 1.49 MB.
Pressure regulators "to ourselves" Danfoss AFA / VFG 2 series (21) DN 15-250. Installation and operation instructions. Language: RU, EN, DE, IT, FR | PDF 6.02 MB.
Pressure regulators "to ourselves" Danfoss AFA / VFG 2 series (21). Technical description. Language: RU, EN, DE, IT, FR | PDF 884.65 KB.
Pressure regulators "After" Danfoss AFD series AFD / VFG (S) 2 (21) DN 15-250. Installation and operation instructions. Language: RU, EN, DE, IT, FR | PDF 3.74 MB.
Pressure regulators "After" Danfoss AFD series AFD / VFG2 (21), AFD / VFGS2 (for steam). Technical description. Language: RU, EN, DE, IT, FR | PDF 951.72 KB.
Danfoss Pressure Delta Regulators Series AFP / VFG 2 (21) DN 15 - 250. Installation and Operation Instructions. Language: RU, EN, DE, IT, FR | PDF 3.37 MB.
DANFOSS DANFE DETAILATORS AFP / VFG Series 2. Technical Description. Language: RU, EN, DE, IT, FR | PDF 849.64 KB.
Danfoss DNFOSS Series AFPA / VFG 2 (21) DN 15-250 Series Dump Regulators. Installation and operation instructions.
Bypass valves DANFOSS AFPA / VFG series 2. Technical description. Language: RU, EN, DE, IT, FR | PDF 678.71 KB.
Bypass valves (regulators) Danfoss series AVPA PN 16, 25 / DN 15 - 50. Installation and operation instructions. Language: RU, EN, DE, IT, FR | PDF 2.17 MB.
Bypass valves (regulators) Danfoss AVP series (RU 16 and RU 25). Technical description. Language: RU, EN, DE, IT, FR | PDF 887.98 KB.
Pressure drop regulators, Danfoss flow limiters AFPB series (-f) / VFQ2 (21) DU 15-125. Installation and operation instructions. Language: EN, DE, FR | PDF 597.42 Kb.
Danfoss Danfoss Pressure Regulators AFPB-F / VFQ2 Series with a fixed setting and manual flow limit. Technical description. Language: EN, DE, FR | PDF 197.75 Kb.
Pressure drop regulators, DANFOSS flow limiters AFPQ series (4) / VFQ 2 (21) DN 15 - 250. Installation and operation instructions. Language: EN, DE, FR | PDF 601.56 Kb.
Pressure drop controls with automatic DANFOSS flow limit AFPQ / VFQ2 series - to install on the return pipe, AFPQ 4 / VFQ2 - to install on the supply pipeline. Technical description. Language: EN, DE, FR | PDF 651.95 KB.
Danfoss flow regulators AFQ / VFQ 2 DN 15 - 250 series. Installation and operation instructions. Language: EN, DE, FR | PDF 1.23 MB.
Danfoss flow regulators AFQ / VFQ series 2. Technical description. Language: EN, DE, FR | PDF 503.85 KB.
Drives Danfoss AFT 06, 26, 17, 27 for temperature regulators. Installation and operation instructions. Language: RU, EN, DE, IT, FR | PDF 2.72 MB.
Thermostatic elements of the Danfoss series AFT 06, 26, 17, 27 for temperature regulators. Technical description. Language: RU, EN, DE, IT, FR | PDF 247.06 Kb.
Danfoss Pressure Delta Regulators AVPB, AVPB-F Series, AVPBT, AVPBT-F (PN 16,25 / DN 15 - 50) with manual flow limit. Installation and operation instructions. Language: RU, EN, DE, IT, FR | PDF 3.01 MB.
Danfoss Danfoss Delta Regulators Series AVPB, AVPB-F (RU 25) with manual flow limit. Technical description. Language: RU, EN, DE, IT, FR | PDF 1.07 MB.
Danfoss Pressure Pressure Regulators AVPB Series, AVPB-F (RU 16) with manual flow limit. Technical description. Language: RU, EN, DE, IT, FR | PDF 1.90 MB.
Danfoss Pressure Delta Regulators AVPQ Series, AVPQ-F, AVPQ 4, AVPQT (PN 16,25 / DN 15 - 50) with automatic flow limit. Installation and operation instructions. Language: RU, EN, DE, IT, FR | PDF 3.25 MB.
Danfoss Danfoss Pressure Regulators, AVPQ 4 Series (RU 25) with automatic flow limit. Technical description. Language: RU, EN, DE, IT, FR | PDF 1.41 MB.
Danfoss Danfoss Pressure Regulators AVPQ Series, AVPQ-F (RU 16) with automatic flow limit. Technical description. Language: RU, EN, DE, IT, FR | PDF 1.97 MB.
DANFOSS Flow Limpers Controllers AVQ Series (In combination with a temperature controller - AVQT) PN 16, 25 / DN 15 - 50. Installation and operation instructions. Language: RU, EN, DE, IT, FR | PDF 2.99 MB.
Danfoss flow regulators AVQ series (RU 25) for feed and return pipelines. Technical description. Language: RU, EN, DE, IT, FR | PDF 496.04 KB.
Danfoss flow regulators AVQ series (RU 16). Technical description. Language: RU, EN, DE, IT, FR | PDF 482.70 KB.
Danfoss temperature regulators AVT series. Installation and operation instructions. Language: RU, EN, DE, IT, FR | PDF 3.05 MB.
Danfoss temperature regulators AVT / VG series - with external thread, AVT / VGF - flange (RU 25). Technical description. Language: RU, EN, DE, IT, FR | PDF 887.47 KB.
Danfoss temperature regulators AVTQ series. Installation and operation instructions. Language: RU, EN | PDF 1.02 MB.
Danfoss Temperature Controllers AVTQ Series (Du 20) with consumption correction. Technical description. Language: RU, EN | PDF 485.27 KB.
Danfoss temperature regulators AVTQ series (DU 15) with consumption correction. Technical description. Language: RU, EN | PDF 680.90 KB.
FJV Danfoss Temperature Controllers. Installation and operation instructions. Language: RU, EN | PDF 566.50 KB.
Reverse Coolant Temperature Regulators Danfoss FJV Series. Technical description. Language: RU, EN | PDF 354.36 KB.
Reverse Coolant Temperature Regulators Danfoss FJV Series. Passport. Language: RU, EN | PDF 221.26 Kb.
Danfoss temperature regulators Ravi series. Installation and operation instructions. Language: RU | PDF 1.66 MB.
Danfoss Temperature Regulators Ravi / RAV8 Series (VMT8, VMA, VMV). Technical description. Language: RU | PDF 986.78 KB.
Danfoss temperature regulators of the RAVV series. Installation and operation instructions. Language: RU | PDF 1.23 MB.
Danfoss temperature regulators of the RAVV / RAV8 series (VMT8, VMA) for use in hot water systems of small buildings (cottages). Technical description. Language: RU | PDF 1.13 MB.
LLC "PROMARMATURE XXI Century" offers a wide range of Danfoss products
A range of products includes: | | | | | | |
Danfoss is the world's largest manufacturer of radiator thermostators. Over the years, Danfoss sold more than 300 million radiator thermostators around the world, which saves a million fuel liters daily and prevent harm caused by the nature of carbon dioxide tons, sulfur compounds and other harmful substances. Radiator thermostators pay off in less than two years, and the standard service life of more than 20 years is a great opportunity to save money and energy.
Danfoss radiator thermostators are manufactured with embedded and remote sensors to ensure optimal functioning; plus a wide range of valves and additional equipment Make up the widest range of our products.
Thermostatic elements of the RA 2000 series are automatic temperature control devices designed to complete the RA radiator thermostators. Radiator thermostat is a proportional direct-acting air temperature controller with a small proportionality zone, which are currently equipped with building heating systems various destination. The thermostat Ra consists of two parts:
All thermostatic elements can be combined with any regulating valves of type RA. Clip connection provides simple and accurate mounting of the thermoelement on the valve. Protective casing Thermoelements RA 2920 and RA 2922 prevents their unauthorized dismantling and reconfiguration with unauthorized persons. Specifications Radiator thermostators type RA correspond to European standards EN 215-1 and Russian GOST 30815-2002.
The main device of the thermostatic element is a bellows that provides proportional regulation. The thermoelement sensor perceives the change in the ambient temperature. The bellows and the sensor are filled with an easy-to-sleep liquidity and its pairs. The adjusted pressure in the bellows corresponds to the temperature of its charging. This pressure is balanced by the power of the tuning springs. With increasing air temperature around the sensor, part of the fluid evaporates, and the pressure of vapors in the bellows grows. In this case, the bellows increase in the volume by moving the valve spool towards the closing of the hole for the coolant duct into the heater until the balance between the spring force and the vapor pressure is reached. When the air temperature decreases, the pairs are condensed, and the pressure in the bellows decreases, which leads to a decrease in its volume and the movement of the valve spool towards the opening to the position in which the equilibrium of the system will again be established. Steam filling will always be condensed in the coldest part of the sensor, usually most remote from the valve body. Therefore, the radiator thermostat will always respond to changes in room temperature, which does not feel the temperature of the coolant in the underwater pipeline. However, when the air around the valve is still heated by heat, given by the pipeline, the sensor can register a higher temperature than indoors. Therefore, it is recommended to establish thermostatic elements to eliminate this influence, as a rule, in a horizontal position. Otherwise, it is necessary to apply thermoelements with a remote sensor.
When choosing a thermostatic element, it should be guided by the rule: the sensor should always react to the air temperature in the room.
Thermostatic elements with a built-in sensor should always be arranged horizontally so that the ambient air can freely circulate around the sensor. Do not install them in a vertical position, since the thermal effect on the sensor from the valve body and the heating system pipe will lead to the incorrect functioning of the thermostat.
Thermostatic elements with a remote sensor should be applied if: o Thermal elements are closed with a deaf curtain; o The heat flux from the heating system pipelines affects the built-in temperature sensor; o The thermoelement is located in the draft area; o required vertical installation of thermoelement. The remote sensor of the thermostatic element must be installed on the furniture-free and curtains or on a plinth under the heating device if there are no pipelines of the heating system. When installing the sensor, the capillary tube should be pulled out to the required length (maximum of 2 m) and fasten it on the wall using the accompanying brackets or a special pistol.
Thermostatic elements of the RAW series - devices of automatic temperature control, designed to complete the RA radiator thermostators. Radiator thermostat is a proportional direct-acting air temperature regulator with a small proportionality zone, which is currently equipped with systems for the heating of buildings of various purposes. The RA type thermostat consists of two parts: a universal thermostatic element of the RAW series and an adjusting valve with a pre-adjustment of the RA-N bandwidth (for two-pipe heating systems) or Ra-G (for a single-tube system).
The program of the production of thermostatic elements of the RAW series includes:
The thermostatic elements of the RAW series are equipped with system protection devices from freezing, fixing and restricting the temperature setting. RAW 5012 is equipped with an ultra-thin capillary tube with a length of 2 m, which is swept inside the sensor housing and connects a remote sensor with a thermostatic element. In the process of installation, the pipe is pulled into the required length. Clip connection provides simple and accurate mounting of the thermoelement on the valve.
The technical characteristics of radiator thermostators with thermoelements of the RAW series correspond to European standards EN 215-1 and Russian GOST 30815-2002.
In order to prevent unauthorized dismantling, the thermoelement can be fixed on the valve using a special retainer (see additional accessories).
The main device of the thermostatic element is a bellows that provides proportional regulation. The thermoelement sensor perceives the change in the ambient temperature. The bellows and the sensor are filled with a special heat sensitive liquid. The adjusted pressure in the bellows corresponds to the temperature of its charging. This pressure is balanced by the power of the tuning springs. When the air temperature is raised around the sensor, the liquid is expanding, and the pressure in the bellows grows. In this case, the bellows increase in the volume by moving the valve spool towards the closure of the heat carrier duct into the heating device until the equilibrium between the spring and the fluid pressure is reached. When the air temperature decreases, the liquid begins to shrink, and the pressure in the bellows decreases, which leads to a decrease in its volume and the movement of the valve spool towards the opening to the position in which the equilibrium of the system will again be established. To eliminate the effect of warm air from heating nozzle of the heating device, it is recommended to set thermostatic elements, as a rule, in a horizontal position. Otherwise, it is necessary to apply thermoelements with a remote sensor.
Thermostatic elements of the RAW-K series are automatic temperature controllers with a small proportionality zone. RAW-K are designed to be installed on the thermostators of HEIMEIER, OVENTROP or MNG firms, built into the steel design panel radiators Type of type Biasi, Delta, Dianorm, Diatherm, Ferroli, Henrad, Kaimann, Kermi, Korado, Purmo, Radson, Superia, Stelrad, Veha, Zehnder-Completto Fix. The thermostatic element of the RAW-K series has a liquid sensor with a temperature setting range of 8-28 ° C and is equipped with a device for protecting the heating system from freezing.
The company "Danfoss" produces 3 modifications of the thermoelements of the RAW-K series:
RAW-K 5032 is equipped with an ultra-thin capillary tube with a length of 2 m, which is swept inside the exhaust sensor housing, connecting it with the thermostatic element working bellows. In the process of installation, the tube is pulled into the required length. The thermostatic elements of the RAW-K series comply with European standards EN 215-1 and Russian GOST 30815-2002.
Electronic radiator thermostat Living ECO® is a programmable microprocessor regulator to maintain a predetermined air temperature, mainly in residential buildings serviced by water heating system. The thermostat is designed to be installed on the closens of radiator thermostators instead of traditional thermostatic elements.
In Living Eco®, the P0, P1 and P2 programs are installed, which allow you to adjust the temperature in the room at different periods of the day.
The P0 program supports constant air temperature throughout the day. P1 and P2 programs in order to save energy can reduce the temperature in the room during certain periods of time, which allows to adapt the operation of the heating system to the lifestyle of people living in it.
The Living ECO® thermostat is supplied with adapters for its installation on Danfoss thermostators, as well as most of other manufacturers. Installing and configuring the Living ECO® thermostat does not represent difficulties, there are only three buttons on its panel.
Thermostat Living ECO® is equipped with a function open windowwhich turns off the flow of the coolant into the heating device with a sharp decrease in the air temperature in the room, which reduces the loss of heat in the way increases the efficiency of the heating system.
The main characteristics of the thermostat:
The function "Long absence" allows to reduce the temperature in the room when it is not operated. The absence period and temperature are adjusted arbitrarily by the consumer.
The selection of programs and their setup are made in accordance with the instructions attached to the thermoelement.
The thermoelectric mini-actuators of the TWA series are designed for a two-position control of various control valves in heating systems and heat-drying of local ventilation plants.
The drive is equipped with a visual indicator of the stroke, which shows, in which position is the valve - closed or open.
TWA actuators depending on the modification can be used with valves of the RA, RAV8 and VMT series manufactured by Danfoss, as well as with HEIMEIER, MNG and OVENTROP valves, having a thread for fastening the drive M 30 x 1.5. In the case of applying a drive with other types of valve valve, the valve must be tested for compatibility of geometry and ensuring its closure. Power supply voltage - 24 or 230 V. Valves can be normally closed in the absence of voltage (NC) and normally open (NO). In addition, the normally closed drive with feed voltage 24 V is supplied with a limit switch (NC / S).
RA-N and RA-NCX regulating valves are assigned to use in two-pipe water heating pumping systems.
RA-N is equipped with a built-in device for preliminary (mounting) adjusting its bandwidth within the following ranges:
Ra-n and Ra-NCX valves can be combined with all the thermostatic elements of the RA, RAW and RAX series, as well as with thermoelectric drive TWA-A.
To identify RA-N and RA-NCX valves, their protective caps are painted in red. The protective cap should not be used to overlap the coolant flow through the heating device. Therefore, the handle should be applied (code number 013g3300).
Valve housings are made of pure brass with nickel coating (Ra-N) or chrome (RA-NCX).
The technical characteristics of the RA-N and RA-NCX valves in combination with thermostatic elements of the RA, RAW and RAX series correspond to European standards EN 215-1 and Russian GOST 30815-2002, and the size of the connecting thread is the HD 1215 standard (BS 6284 1984). All radiator thermostators manufactured by Danfoss are manufactured at factories with ISO 9000 quality certificate (BS 5750).
To prevent deposits and corrosion valves of RA-N and RA-NCX thermostators should be used in water heating systems, where the coolant meets the requirements of the maintenance of electric stations and networks Russian Federation. In other cases, it is necessary to contact the company "Danfoss". It is not recommended to use compositions containing petroleum products (mineral oils) to lubricate the valve parts.
Setting on the calculated value is made easily and accurately without the use of special tools. To do this, make the following operations:
Pre-configuration can be performed in the range from "1" to "7" at intervals of 0.5. The "N" position valve is fully open. Installation should be avoided on a dark zone scale.
When the thermostatic element is mounted, the pre-tuning is hidden and, thus, protected from an unauthorized change.
The RA-N valve is designed for use in two-pipe water heating pump systems with copper or stainless steel pipelines. To connect the valve with a pipeline with a pipeline, special crimping tools are required. Valve Case for appearance and the technical characteristics are identical to the standard valves Ra-N DN \u003d 15 mm. Ra-n can be used with any types of thermal static elements of the RA or RAW series, as well as with thermostatic elements of a special design of type RAX and thermoelectric TWA-A thermoelectric drive.
The RA-N control valve is equipped with a built-in device for preliminary (monkent) adjusting its KV bandwidth in the range from 0.04 to 0.73 m3 / h.
To identify valves, the protective cap is painted in red. The cap should not be used to overlap the adjustable medium. To this end, it is necessary to use a special metal handle (code number 013G3300). The valve body is made of nickel-plated brass DZR, and the pressure pin is made of stainless steel. The pin does not require lubrication over the entire life of the valve. The gland seal can be replaced without emptying the pipeline system. Ra-n should be used in water heating systems, where the coolant meets the requirements of the maintenance rules of electrical stations and networks of the Russian Federation. In other cases, it is necessary to contact the company "Danfoss". It is not recommended to use formulations containing oil products (mineral oils) to lubricate the valve parts.
The valve thermoregulating with increased bandwidth RA-G is designed for use, as a rule, in single-pipe systems of water heating with a pumping circulation of the coolant that meets the requirements of the technical operation of electric stations and thermal networks of the Russian Federation. The valve is not recommended to be used if impurities of mineral oil are present in the coolant.
RA-G is equipped with a seal that can be replaced without emptying the heating system. The pressure pin in the gland is made of chrome steel and does not require lubrication over the entire life of the valve. All performances of RA-G valves are combined with any thermostatic elements of the RA series.
Ra-G valves are supplied with gray (for identifying) protective caps that should not be used to overlap the coolant flow. Therefore, a special metal service locking handle should be applied (code number 013G3300).
The thermostatic X-TRA ™ kit is specifically designed for heated towel rails. It consists of a thermostat valve, a thermostatic element and a shut-off valve with a drainage function. Innovative self-adhesive connection of valves to the radiator is carried out using a thread one second inches. Valves and thermoelement are available in white, chrome-plated and steel versions, suitable for most heated towel rails. This kit is the perfect ending of the heated towel rail. Attractive and compact design allows you to install the thermostat under the heated towel railway parallel to the wall, eliminating random strikes on it.
Nomenclature presents two types of thermostators with various principles of regulation:
The valve assembly is a housing with a two-sided self-fitting fitting, which has two sealing rings: one - to compact fitting compound with a heated towel rail, second to seal fitting compound with valve body. The screw with an internal hexagon is used to ensure the sealing of the valve body compound with the fitting. If the sealing rings are not suitable for the fittings of the heated towel rail, the traditional sealing material is used.
Installation on the thermostat radiator is the ability to reduce the cost of heating, improving the microclimate in the house, as well as the maintenance of Earth energy resources.
The motives can be different, but the decision is incarnated in life more and more.
Many, choosing equipment manufacturer, stop at Danfoss.
And not surprisingly, the products of the famous brand are easy to meet on the shelves of many stores.
The production technology of their thermostats based on a gas-filled bellows is patented and applied at its own company plants. If you also decided to purchase a Danfoss thermostat, the installation and operation instruction will be by the way.
The goal of the installation of the thermostat is maintaining the selected by the consumer, the air temperature in the house.
The design of the thermostator for radiators includes two elements, complementary by each other:
The valve is connected directly to the battery, and the thermostatic element is installed on it.
Basis base is a thermostat. It is he who reacts to a change in the ambient temperature and affects the valve that overlaps the coolant stream.
Temperature regulator Danfoss.
Inside the thermostat head - a bellows (corrugated chamber capable of changing the size), filled with gas. Gas, depending on the temperature, changes its aggregate state (chilled it condensed). This leads to a change in volume and pressure in the chamber. The camera decreases in size, pulls the stem of the spool, which opens a greater clearance in the valve for the receipt of the coolant.
When heated, the reverse process of expanding and overlaping the lumen occurs (adopted standard - 2 V ° C of excess air temperature over specified).
When a comfortable temperature is displayed on the regulator scale, a certain compression of a tuning spring is established inside, which is interconnected with a certain gas pressure.
Danfoss produces gas bellows inside, as well as liquid. The latter are more inert, react to a change in temperature slower.
Danfoss Radiator Regulators RA 2991
There are also modifications of thermoelements in which:
Extraction electricity from the Earth is interested in many people. - How to get your own hands, read in the article.
Formulas and examples of the calculation of ventilation production premises you'll find .
With reviews about efficiency electrical convectors You can familiarize yourself with heating.
Thermostators are used for the heating system of floors. The thermostat for warm floors is simply necessary!
After all, driving fluid into the floor circuit, you need to lower its temperature from 60 to 90 in ° C, to a comfortable 35 - 40 V ° C (while the surface of the floor itself will be about 25 in ° C).
Flow meters are powerless if the pressure is jumping in the system if the air heats up, for example, from the Sun, and even if the tenants want to save on heating during their absence.
Thermomechanical regulator is better to apply for small rooms, about 10 m2.
For large squares Use room thermostat with a warm floor temperature sensors.
First of all, the valve on the radiator is mounted. For this, the flow of the coolant is overlap.
The thermal head is set to the maximum temperature value, after which it dresses on the valve with pressing (before clicking).
As already mentioned, the remote sensor is needed if the battery is built into the wall or something closed (furniture, screen, dense curtains).
In one case of this item, a sensor and a tuning node are combined.
Microclimate in the house and humidity of the air - two inextricably linked concepts. For home and health, read it in the article.
Which insulation for a warm floor to choose, read. And you will find general information About laying insulation.
At the heart of the work of thermostators - physical laws. Therefore, you need to remember that the conditions in which the device is located can be made some adjustments (for example, remoteness from the heat source). There are approximate tables of compliance of the regulator scale and temperature, which can be taken beyond the landmark when installed. However, after the main setting it will be necessary to "understand" its thermostat.
For this:
The proportionality zone is 2 ° C. If you set a temperature of 20 °, the device will hold the indicators ranging from 20 to 22 ° C.
Sensor after installation on the radiator
Two pin, which are included in the sensor, help set limitations of the minimum and maximum position of the thermoelement.
They are at the bottom of the device:
For this:
Danfoss thermostators have many positive feedback. This is a very easy-to-use device that does not require any attention after the initial installation and settings. But the result will be a more comfortable temperature in the apartment, as well as in some cases, substantial savings of budget funds.
Danfoss thermostators for heating and heating radiators
5 (100%) Votes: 1The popular brand under which thermostat is produced is Danfoss. Products of this company can be found in almost all stores.
The production technology based on a gas-filled bellows has a patent and is used on its own company plants. If you are leying for the purchase of the Danfoss thermostat, then be sure to read the instruction manual.
Check the price and buy heating equipment And you can have accompanying goods. Write, call and come to one of the shops in your city. Delivery throughout the Russian Federation and CIS countries.
Why are the thermostat set? To maintain a certain air temperature in the premises.
It consists of a product of two parts that complement each other:
The Danfoss thermostat valve is connected directly to the radiator, and the thermostat is already mounted on it.
The main thing is a thermostatic element that catches the temperature changes and gives a signal to the valve overlapping the heat carrier stream.
Inside the thermal heads - the bellows (corrugated chamber that can change dimensions) with gas. The gas at a certain temperature changes its state (when cooled condenses). This affects the change in the volume and pressure in the chamber, which becomes smaller in size and pulls the range of the spool, which turns out in turn in the lumen valve for circulating the heat carrier.
When heating occurs, the reverse expansion process starts and the lumen is overlapped (the standard is considered to be 2 in ° C of the temperature indicator above the specified).
When putting an optimal degree on the scale of the device, a certain compression of the setting spring appears inside, which is associated with a specific gas pressure.
Danfoss produces gas bellows and liquid (more inert, slower react to temperature fluctuations).
Abbreviations, according to which the heating thermostators Danfoss differ, mean the type of filler and the appointment of the device:
Service thermostatic Danfoss RTR / RTD element with integrated temperature sensor
There are modifications that perform not only their main functions, but also a lot of additional. Suppose the option of protection against the reconfiguration of the established indicators. It is convenient when children are constantly in the room. The number of modes and a variety of functions in each model individually.
In the company's assortment series, many different temperature controls Danfoss for batteries. The following are popular:
Danfoss Living Connect thermostat
All Danfoss thermostators for heating radiators have parts that simplify the device fastening and its future use.
The device is mounted on the hot water circuit pipe. Installation does not mean anything complicated, even in the case of designer options, the installation occurs according to one principle. The work is carried out in stages:
If the DANFOSS thermostat is connected correctly, there should be no problems. It is worth checking the operation of the device to the first opening and closing of the valve.
All manufacturer's devices differ in externally and technicians, but still their setup is made equally. To implement it, it is necessary to look into the instructions for use and familiarize yourself with the designation of the modes, which are indicated on the instrument housing. Indicators may differ, it all depends on the model.
Next, to adjust the Danfoss thermostator, put the required temperature on it. This can be done using the movement of the torque element in a specific side. If you installed the device with the buttons, everything you need is to click on the "plus" or "minus".
It is possible to specify intermediate values \u200b\u200bwhen they are best suited to create a certain temperature mode in room. Will be a couple of minutes and heating system It will be time to adjust the specified parameters and will warm until the optimal microclimate is obtained. Also tuning and for refrigeration equipment.
Danfoss warm floor thermostat is an important thing for the entire heating system. The device lies a responsible function to adjust the temperature to a comfortable 25 ° C.
Flow meters will not help if the pressure is unstable, the air heats up, let's say, solar rays, and the tenants seek to save on heating while they are not at home.
Mechanical regulator Specialists advise to put in small rooms by about 10 m².
IN large rooms Apply indoor thermostators Danfoss with temperature sensors of the warm floor.
The thermostatic head Danfoss deservedly has many positive feedback. This is an easy-to-use element that does not require special attention from the owner after installation and adjustment. As a result, a favorable microclimate is ensured in the house, and in some cases, and tangible cash savings.
In many countries, up to 40% of energy resources goes to the needs of ventilation and heating of buildings. It is several times more compared to advanced European states.
The issue of energy saving is especially acute, it is relevant against the background of a constant increase in energy prices. One of the devices that saves thermal energy- This is a thermostat for radiators, its installation reduces heat consumption by 20%. To do this, the consumer needs to be correctly selected to the design to the heating system, as well as make installation, you can find out if you read below.
The Danfoss thermostat is designed to support the constant temperature indoor. For the first time such devices began to be used in 1943. The company mentioned is the market leader in the production and sale of such aggregates. Constructively, the devices are in composition 2 of the main element, namely the thermal head and the valve, which are connected by the locking mechanism. The purpose of the thermal head is to determine the ambient temperature to adjust the impact on actuating mechanism, the latter protrudes the valve. It is designed to cover the flow of water that enters the radiator. Such a regulation method is called quantitative, as the device can affect water consumption that goes into the battery. There is another method called high-quality, with its help the water temperature changes in the system. This is done by name, namely, this element must be in or boiler. The Danfoss thermostat has inside the bellows, which is filled with a heat sensitive medium. It can be gas or liquid. The last variety of bellows is easier in manufacture, but does not show such speed as gas analogues, so the latter have gained so widespread. At the time of increasing the level of air temperature, the substance that is in a closed space acquires a more impressive volume, the bellows, stretching, has an impact on the valve stem. The latter move down the cone, which is designed to reduce the passage section. This allows you to effectively reduce water consumption. With a decrease in air temperature, this process proceeds in the reverse order, and the volume of the coolant increases to the optimal limit, and the Danfoss thermostat works.
Depending on which type of heating system is used, as well as the installation technology, thermal heads and valves can be used to control water flow. of different combinations. If we are talking about a single-tube system, the valve should be applied, which is characterized by increased bandwidth and insignificant, according to users, the same recommendation can be used and in the case of a two-pipe samotane system, where the water circulates naturally and does not affect the forced motivation. If you decide to choose the Danfoss thermostat, then you can install it on a two-pipe system, which is equipped with a circulation pump. In this case, according to the reviews, the valve must have the ability to adjust the bandwidth. It is fairly simple, and it is not necessary to apply a special tool for this. After you decide what valve to use, it is necessary to determine the type of thermal head.
If you are interested in Danfoss - the thermostat, the installation instructions for which will be presented below, - you can purchase it at an affordable cost. Determining the type of thermal heads, you should know that it is proposed for sale in some varieties. Thus, inside may be a thermoelement. Among other things can be remote. Sometimes the regulator is external. The devices are also programmable, in this case they are electronic. You can choose and anti-vandal thermal head. According to users who chose a regulator with an internal sensor, this device It should be installed only if it is possible to arrange it horizontally. Then the air in the room will freely go to the instrument housing.
After the Danfoss radiator thermostat was acquired, it is worth familiar with the features of its installation in more detail. Thus, it is completely unacceptable to install it on the radiator in a vertical position. In this case, the heat flux will constantly rise upwards, and elevated temperatures from the feed pipeline and the housing will influence the bellows. In the end, you will come across that the device will work incorrectly.
Homemade masters especially emphasize that in some cases there is no possibility to install the device horizontally. Then it is recommended to buy a remote one that comes with a capillary tube. The length of the device is 2 meters. At such a distance from the battery, it is recommended to have a device by installing it on the wall. Buyers emphasize that not always the absence of the installation of the regulator horizontally indicates the need to purchase a remote sensor. This may be other objective reasons. The Danfoss Temperature Regulator, the principle of operation was described above, cannot be installed for dense curtains, in this case, of course, better decision It will be the purchase of a remote sensor. Among other things, such a need arises in the case when there is any source of heat next to the thermal head or the hot water pipes pass. You can resort to such a solution, and when the radiator is under a sufficiently wide window sill. In this case, the thermoelement can fall into the area of \u200b\u200bthe draft. Buyers claim that if at least one of the above conditions is observed, it is best to get a remote sensor.
The Danfoss Temperature Regulator, the reviews about which are presented in the article should be installed according to a specific technology. As the first recommendation, it is an elimination of the installation of the thermal heads on the heater within visibility. Regulation should be subject to battery whose total power is 50 percent and more from all that are in the same room. Thus, when there are two indoors heating devicesThe thermostat must be on the same battery whose power is more impressive. If you are interested in Danfoss - a thermostat, the setting of which is simply made enough, it can be purchased and installed. The first part of the device whose role is the valve, should be installed on the feed pipeline. If it is necessary to embed it to the already assembled system, the feed liner must be dismantled. These works may assume some difficulties if the connection is made using steel pipes. The master will have to stock material tool.
A fairly popular company today in the market of relevant goods is Danfoss. The thermostat (how to adjust it is indicated in the instructions) must be installed on the radiator. The thermal head is then mounted without using an additional tool. It is very easy to do at home, in addition, it will be possible to save on the purchase of consumables.