House, design, renovation, decor.  Courtyard and garden.  With your own hands

House, design, renovation, decor. Courtyard and garden. With your own hands

» Air conditioner gree error codes e1. Error codes for all brands of air conditioners and split systems

Air conditioner gree error codes e1. Error codes for all brands of air conditioners and split systems

AUX, DAX, Renova, JAX, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu (Daihatsu), Vitek, - digital display for a series of air conditioners faults:

  • Display mode = E4
  • Priority level display = 1 Non-mitsubishi52_63_71he-s power supply defective = Plastic temp sensor is abnormal.
  • Display mode = E1 Display priority level = 2
  • Power supply failure = Copper temperature sensor abnormal (indoor) Display mode = E3 Priority level display = 3
  • Power supply failure = Copper temperature sensor abnormal (open, no signal) Display mode = E2 Priority level display =
    4

2.H series - AUX, DAX, JAX, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu (Daihatsu), Renova (except KFR-25G / H) h3 HA HB series malfunction display:

  1. Power supply failure = PG motor feedback abnormal
  2. Priority level display = 1 Power supply failure = Plastic sensor temp abnormal Display mode = Timer LED blinks 1 time every 8 seconds
  3. Priority level display = 2 Power supply failure = Copper temperature sensor abnormal (indoor) Display mode = Timer LED blinks 2 times every 8 seconds
  4. Priority level display = 3 Power supply failure = Copper temperature sensor abnormal (indoor) Display mode = Timer LED blinks 1 time every 1 second
  5. Display priority level = 4

3. Series H (Y) air conditioner model remote display, removable panel AUX, DAX, JAX, Pioneer, Vitek, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu:

  1. Power supply failure = PG motor feedback abnormal Display mode = Timer LED blinks 4 times every 8 seconds Priority level display = 1
  2. Power supply failure = Plastic temp sensor. abnormal Display mode = Timer LED blinks 1 time every 8 seconds Priority level display = 2
  3. Power supply failure = Copper temperature sensor abnormal (indoor) Display mode = Timer LED blinks 2 times every 8 seconds Priority level display = 3
  4. Power supply failure = Copper temperature sensor abnormal (open, no signal) Display mode = Timer LED blinks 1 time every 1 second Priority level display = 4

4. E. E. E. Yu. EC EZ EAA EAD EL HS1 HSZ HL1 HLZ P P1 ZZ CZ digital display series of air conditioners AUX, DAX, Renova, JAX, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu (Daihatsu), troubleshooting:

Power supply failure AUX, DAX, JAX, Pioneer, Vitek, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu = PG motor feedback abnormal Display mode = E4 Priority level display = 1

E1 or EL - as a common power error.

Malfunction of the power supply or, in Russian, the voltage in the network< 210 В (сработала защита – токовая нагрузка) = Датчик темп ненормально Режим отображения = E1 Отображение уровня приоритета = 2

E1 is a fairly common mistake, I ran into it just yesterday.

    The reasons for E1 are obvious - insufficient mains voltage< 210 В. При пуске компрессора происходит дополнительная просадка напряжения, токовая нагрузка max.
    Power supply failure = Copper temperature sensor abnormal (indoor) Display mode = E3 Priority level display = 3

1

1

5. All other E series, except EA EC E. M. E. Yu. Z. EAA EAD:

Power supply failure = PG motor feedback abnormal

Display mode = Timer LED blinks 4 times every 8 seconds

Priority level display = 1 Power supply failure = Plastic temp sensor. abnormal Display mode = Timer LED blinks 1 time every 8 seconds

Priority level display = 2 Power supply failure = Copper temperature sensor abnormal (indoor) Display mode = Timer LED blinks 2 times every 8 seconds Priority level display = 3

6. QA QB QD digital display series of air conditioners AUX, DAX, JAX, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu (Daihatsu), Vitek, Renova - malfunctions, error codes:

  • Power supply failure = PG motor feedback abnormal Display mode = E4
  • Priority level display = 1 Power supply failure = Plastic sensor temp abnormal Display mode = E1
  • Priority level display = 2 Power supply failure = Copper temperature sensor abnormal
  • Display mode = E3 Display priority level = 3 Power supply fault = overcurrent oprotection
  • Display mode = E6 Display priority level = 4

1

1

7. QC QQ light display series of air conditioners malfunction:

  • Power supply failure = PG motor feedback abnormal
  • Display mode = Timer LED blinks 4 times every 8 seconds Priority level display = 1 Power supply failure = Plastic temp sensor abnormal
  • Display mode = Timer LED blinks 1 time every 8 seconds Priority level display = 2 Power supply failure AUX, DAX, JAX, Pioneer, Vitek, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu = Copper temperature sensor abnormal
  • Display mode = Timer LED blinks 3 times every 8 seconds Priority level display = 3 Power supply failure = overcurrent oprotection
  • Display mode = Timer LED blinks 6 times every 8 seconds Priority level display = 4

1

1

8. Display malfunctions of semi-industrial series 18000BTU ~ 24000BTU, AUX, DAX, JAX, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu (Daihatsu), Renova - wall-mounted series of air conditioners:

  • Numbers for digital handset displays:
  • Power supply failure = PG motor feedback abnormal
  • Display mode = Timer LED blinks 1 time every 8 seconds Priority level display = 2
  • System errors = turns off Power supply failure = Plastic temp sensor abnormal Display mode =
  • Timer LED blinks 2 times every 8 seconds Priority level display = 3 System errors = turns off
  • Power supply failure = Copper temperature sensor abnormal Display mode = Timer LED blinks 8 times every 8 seconds Priority level display = 4
  • System errors = does not turn off Digital tube displays: Power supply failure = PG motor feedback abnormal Display mode = E1
  • Priority level display = 2 System errors = turns off Power supply failure = Plastic sensor temp abnormal Display mode = E3
  • Priority level display = 3 System errors = turns off Power supply failure = Copper temperature sensor abnormal Display mode = E2 Priority level display = 4
  • System errors = does not turn off

Baloo air conditioner error codes are required in order to timely identify the malfunction and contact the master to fix it. It should be noted that in some cases the slightest delay becomes critical, so it is better to monitor the appearance of information on the scoreboard.

True, the errors of Balu air conditioners directly depend on the series. Because the equipment is different software, which means that it informs a person about malfunctions in different ways. This means that all possible codes should be considered depending on the series.

Errors on the example of Ballu MFS2

Errors of air conditioners Balu of the MFS2 series:

  • E1, E2, E3, E4 - an error of the Ballu air conditioner, indicating that the temperature sensor has been cut off or short-circuited;
  • E6 shows emergency activation of the protection of the outdoor unit;
  • E8 - an error of the Ballu air conditioner, which requires cleaning the electrostatic filter;
  • P4 - the compressor automatically turned off, as an error appeared on the evaporator sensor, which occurs when the temperature threshold is exceeded;
  • P5 - this error code Ballu air conditioner shows when an error appears on the condenser sensor;
  • P6 will prompt that defrosting has started automatically.

The number of codes shows how much information a person receives about the operation of his own equipment.

Accordingly, he can contact specialists at the right time.

Below is the most complete list of error codes and malfunctions found in this technique in general.

Errors of the Balu air conditioner of the BSC, BR, BV series

  • E1, this error code of the air conditioner is displayed when the indoor temperature sensor does not work properly;
  • E2 - error of the evaporator temperature sensor;
  • E5 indicates that an error occurred in the outdoor unit, which led to the automatic activation of the protection mode;
  • E6 are errors of Baloo air conditioners, showing a malfunction of the fan motor in the indoor unit.

It is immediately clear that the last three series have much less codes. On the one hand, this shows how stable the models are considered. On the other hand, the user receives less information, which often leads to difficult situations and additional diagnostics of cassette air conditioner models.

Air conditioner error codes are useful information that appears on the equipment screen. If you recognize them correctly, you will be able to find out exactly which malfunction should be eliminated. Because of this, maintenance takes a minimum of time, which means that the owner does not have to suffer from a lack of equipment.

Comfortable life modern people practically unimaginable, especially in the hot season, without the presence in residential, office and production premises air conditioners different types... Failure of the split system in hot summer, and if it is used for heating the room, then in winter is a big problem that requires an immediate solution.

In this regard, the residents of Moscow are very lucky, who have the opportunity to use the services of masters. service center"ETechnik", which diagnose the malfunction of the air conditioner and eliminate it right at the clients' home. Although modern split systems are capable of self-diagnosis, and therefore, focusing on the error codes of air conditioners, or rather on their decoding, since it is unlikely that an ordinary person knows what an eeprom error is, you can independently find out which specific malfunction is in question.

Frequent error codes for air conditioners of various brands

Self-diagnosis systems of modern equipment, with the help of which air conditioning is carried out, are designed to self-test the performance of split systems, and if a malfunction is detected, notify users about this by highlighting error codes on the displays of indoor modules and / or remote controls.

Modern air conditioners and split systems are created on the basis of microprocessors, which leads to almost complete automation of the air conditioning control process, and, in addition, allows you to monitor the health of the equipment and how it works. Moreover, the microprocessor stops the system if it detects a malfunction, and, in addition, provides real assistance to specialists in identifying faulty components and parts, displaying error codes on the screen.
Next, we will discuss in more detail the most common error codes for air conditioning systems of popular brands.

Panasonic air conditioner error codes

Panasonic air conditioners enjoy well-deserved popularity due to modern design, high build quality, reliability, almost silent operation. However, they are also prone to breakdowns for a while, which they notify their owners about by displaying codes indicating a particular malfunction on the displays.

Codes Decoding the code and the essence of the problem Causes of the problem
Error H11 The air conditioner error code indicates a communication failure between the outdoor and indoor units, which is not established after thirty seconds have elapsed since the start of the unit. After the indicated error is fixed, it is likely that the fan of the indoor unit will work. The occurrence of the indicated malfunction may be due to incorrect wiring of the interconnect wires. In addition, in this way the processor can signal the failure of the electronic control boards of the external and internal units.

Error H14

With this code, the processor notifies users that the internal (room) air temperature sensor is faulty. This error fixes the fact that the room is set too high or, on the contrary, too low temperature. This malfunction is due to its appearance to an open circuit or short circuit (SC) in the sensor.

Error H19
Thanks to this error, the user knows that the motor of the indoor unit (ICU) is stuck. This is manifested by the discrepancy between the actual speed and the value set by the processor. The occurrence of this malfunction can be caused by several reasons:

· Breakdowns of the motor itself;

· Failure of the board of the indoor unit;

· Malfunction of the connectors of the MVB wires.


Error H21
Illumination of this code on the air conditioner display indicates a malfunction of the float sensor

drain pan of the indoor unit.

This malfunction is due to a blockage. drainage system... In such a situation, check the logic of the sensor and the resistance of the pump motor windings.

Error H23
The indicated error indicates a violation of the operating mode of the basic sensor (No. 1) of the temperature of the heat exchanger of the indoor unit.

The problem can be triggered by the fact that the sensor is cut off, or by a short circuit in the specified sensor.


Error H24
Thanks to this error, users will learn about the failure of the sensor No. 2 of the temperature of the heat exchanger in the indoor unit. The causes of the problem are the same as in the case of sensor # 1.
Error H27 This code is an indication that there is a breakdown of the outdoor temperature sensor.

The problem stems from the same reasons as outlined in the two previous paragraphs.

Error H28

The indicated error indicates a malfunction of the sensor # 1 of the outdoor unit temperature. A breakdown can also be connected with an open circuit or a short circuit in the sensor.
Error H30 This is a failure of the compressor discharge temperature sensor. The problem may be due to an open circuit or short circuit.

Error H35

This is an error in the drain pump. This breakdown is usually caused by a blockage in the drainage system. To restore work drain pump usually the resistance of the windings is checked

its motor, the value of which should be approximately 200 ohms.

Error F11

This code is displayed when the four-way switching valve is not working correctly.
cold / warm.
The indicated problem may be due to a malfunction of the solenoid coil of the valve in question.

In addition to those already listed above, there are error codes for Panasonic air conditioners, so, for example, those that indicate problems:

  • with temperature sensors in the indoor units of air conditioners;
  • with air temperature sensors;
  • with evaporator temperature sensors;
  • with temperature and pressure sensors;
  • with radiator temperature sensors;
  • with protective devices, etc.

And these are not all error codes for Panasonic air conditioners, and they are not needed by ordinary users, since the repair of the discussed units should be trusted only by professionals, for example, those who work in the Moscow service center "ETechnik".

LG air conditioner error codes

Another very popular brand of household appliances is LG air conditioners and split systems, which is due to its significant advantages: original design, great variety colors, excellent quality, a large number of various, including innovative functions, and, of course, a high degree of reliability. But even with these units, breakdowns occur, and therefore their happy owners will need information about the error codes of LG air conditioners.

Error code The order of flashing of the LED in case of malfunctions Causes
a problem

Trouble-shooting

Error 1 One blink after 3 seconds This code indicates that one of the thermistors of the indoor unit board is faulty, which controls the temperature of the outdoor air and the refrigerant pipe of the unit. This could be caused by an open circuit or a short circuit. To eliminate the malfunction, first check the thermistors, and if necessary, the internal block of the split system is changed.

Error 2

Two flashes after 3 seconds This error indicates a failure of one of the outdoor unit thermistors. We are talking about an outside temperature sensor or a refrigeration pipe of the unit. If such an error is displayed, the wizard first of all checks for
malfunctions in thermistors.

Error 3
3 flashes after 3 seconds This error indicates that there is a simultaneous operation of the split system for both heating and cooling. If we talk about the causes of the malfunction, then in such cases, as a rule, there is an error when connecting the split system during its installation.

Error 4
4 flashes after 3 seconds The indicated error indicates that the compressor overload protection is connected.

If the discussed error occurs, a specialist checks the compressor overload protection system for current overload, gas pressure in the system, etc.


Error 5
5 flashes after 3 seconds

This error indicates a violation in the exchange of data between the indoor and outdoor units of air conditioners with each other.

This is most likely a violation of the connection between the outdoor and indoor units. In this case, a check is carried out cable lines for the possibility of their breakage or a short circuit that has occurred. To troubleshoot, it is often necessary to change the interconnect cable.

Error 6
6 flashes after 3 seconds This error indicates the existence of a problem due to the fact that one or more relays of the outdoor unit consumed current above the norm for a short period of time. To eliminate the problem, the operability of the actuators of the outdoor unit is checked, and, in addition, there is a possibility that their control elements are faulty - it is the key power relays.
Error 7
7 flashes after 3 seconds

This error suggests that outdoor unit consumed a current above normal for a long time.

When such an error occurs, the master checks the refrigerant pressure in the evaporator-condenser system, and, in addition, checks the elements of the outdoor module for serviceability

air conditioners.

Error 8

8 flashes after 3 seconds The indicated error indicates that we are talking about the fact that the fan motor is faulty, which, of course, is manifested by a violation or lack of rotation of the fan. If this error occurs, then the engine, the elements of its control circuit and the terminal contacts are checked for serviceability.
Error 9
9 flashes after 3 seconds
This error indicates a malfunction of a part such as a four-way valve. When the indicated error occurs, then the specified valve is checked for its serviceability.

Error 10

10 flashes after 3 seconds This error is an indication of a malfunction of the thermistor that monitors the temperature of the compressor casing. The occurrence of a problem can be associated with an interruption in the network or a short circuit. After checking the health of the thermistor, if necessary, change it.

Air conditioner error codes Mitsubishi Heavy

Mitsubishi Heavy Ind ranks among the world leaders in manufacturing, in particular household air conditioners and split systems. This is not surprising, since the HVAC equipment of this brand is characterized by a number of undoubted advantages, so, for example, we are talking about:

  • about durability;
  • about efficiency;
  • the presence of a large number of functions;
  • low noise level;
  • about high power;
  • about the comfort of air conditioning;
  • about reliability, etc.

However, as you know, "nothing lasts forever under the moon", and therefore reliable air conditioners of this brand are susceptible to breakage. It is very convenient that these "smart" devices are capable of self-diagnostics, and notify their owners that this or that malfunction has been detected. The conversation is about the error codes of Mitsubishi air conditioners, the most common of which can be found in the table below.

Air conditioner error codes
Mitsubishi Heavy

How are Mitsubishi Heavy air conditioner error codes decoded?
E1 This error signals that "failed" printed circuit board indoor unit, or we are talking about a malfunction or incorrect connection of the remote control.

E3
The indicated error indicates that the address of the outdoor unit is incorrect.

E5
The indicated error is evidence of a malfunction of the control board of the outdoor unit.

E6
This error signals a malfunction of the evaporator temperature sensor, which can be triggered by an open circuit or short circuit.
E8 This error indicates an overcurrent in the evaporator or a sensor malfunction.
The indicated error indicates that the address settings are incorrect.
This code indicates that a fan error has occurred.
E28 This error is evidence of a malfunction of the control panel sensor.
The indicated code is evidence that an error has occurred in connecting the outdoor and indoor units.
E33 This is an error indicating a break in the compressor winding.
E35 The indicated error indicates a high condenser temperature or

temperature sensor malfunction.

E37 The occurrence of this code is due to the presence of a malfunction of the condenser temperature sensor.
E38 This error occurs if there is a problem with the outdoor temperature sensor.
E39 This code indicates that there is an error in the discharge pipe temperature sensor.

E49

The indicated error indicates that there is a malfunction associated with a system shutdown, which occurred due to an insufficient amount of refrigerant or low pressure, which, in turn, may be caused, in particular, by a refrigerant leak.

This error indicates a disconnection

low pressure sensor.

E63 This error indicates a malfunction associated with an emergency shutdown of the indoor unit.

Ability modern systems conditioning to self-diagnostics and the issuance of error codes extremely helps in identifying their malfunctions, which significantly speeds up and facilitates the repair of this equipment. However, it should be noted that there are a huge number of error codes for air conditioners of any brands, but they are usually used by specialists. For example, with regard to Mitsubishi Heavy air conditioners, then, in addition to those already mentioned, there are error codes indicating that there are problems:

  • with internal non-volatile memory;
  • with an indoor unit temperature sensor;
  • with blocking sensor;
  • with high pressure sensor;
  • with current sensor;
  • with motor or fan board;
  • with the fan motor of the indoor module;
  • with fan motor;
  • with a compressor motor, etc.

Note that if a particular malfunction of air conditioners is detected, they should be repaired by resorting to the services of professionals, in particular, those who work in the Moscow service center "ETekhnik".

Toshiba air conditioner error codes

Toshiba air conditioners are very worthy representatives of modern climatic equipment, which compare favorably with similar equipment from other brands in compactness and uniqueness of style. Therefore, error codes for Toshiba air conditioners are of interest not only to specialists who repair household appliances, but also to the owners of these units.

Air conditioner error codes
Toshiba

How Toshiba air conditioner error codes are decoded
00-0d

This code means that there is an error in the control board, or the sensor responsible for the temperature of the radiator is faulty.


01-04
This error indicates a burnout of the board or its fuses. In addition, this code may indicate that an interconnect error has occurred.

01-05
This error indicates a malfunction of the inverter board.

02-17
The indicated error indicates a malfunction in the compressor current sensor.
02-19 This code indicates that a board temperature sensor error has occurred.

This table contains only a small part of the errors detected by self-diagnostics. In fact, error codes for Toshiba air conditioners, like other brands, are much more widely represented. The codes cover many malfunctions, for example, related:

  • with problems in protection in external blocks;
  • with problems with the capacity of indoor units;
  • with malfunctions of external heat exchangers;
  • with cooling problems;
  • with communication errors;
  • with errors in the connection of outdoor units;
  • with errors on indoor units;
  • with breakdowns of the boards of outdoor units;
  • with poor engine performance;
  • problems with signal transmission of controllers;
  • with problems associated with the fact that there was an error in some sensor;
  • with malfunctions of power modules;
  • overloaded fan motor;
  • with problems associated with the supply voltage;
  • with high temperature outlet air;
  • with a malfunction of the air temperature sensor in the system;
  • with sensor response problems, etc.

All indicated and many other malfunctions, which are indicated by air conditioner error codes, will be quickly and efficiently eliminated experienced craftsmen Moscow service center "ETekhnik" at more than reasonable prices. By the way, the specialists of this company will eliminate any malfunction. household appliances all famous brands.

Daikin air conditioner error codes

The demand for high quality, reliable Daikin air conditioners is well known. But since they, like any other household and not only appliances, sometimes fail, their error codes are certainly of interest to users. This is not surprising, because error codes, in fact, are very useful "readings" reflecting the results of self-diagnostics of air conditioners, which is of great benefit, first of all, to specialists in finding any malfunction.

The table below shows the most common error codes for Daikin air conditioners.

Daikin codes
How to decode Daikin codes

Code A0

This error means that a general protective device has been triggered.

Code A9
If the indicated error is displayed on the display of the air conditioner of the brand in question, then this indicates a malfunction of the electronic expansion valve.

Code A7
This error indicates that there is a malfunction in the louver drive in the air conditioner.

EF code
This error indicates a defective heat storage unit.
JA code This error is evidence of a malfunction of the compressor discharge sensor.

FA code

The indicated error on the air conditioner display indicates a malfunction that entails an unacceptable level of discharge pressure.

FF code
This error indicates a malfunction that results in an unacceptable oil level.

Code 6H

This error notifies the owner of the air conditioner about the open door switch.
Code E2 This code indicates that there is a malfunction that occurred during the zero crossing.
P5 code The appearance of the indicated code on the display of air conditioners indicates a malfunction that has occurred due to high or low temperature.
CU-2E code This code indicates a malfunction of the temperature sensor in the discharge pipe of the compressor.
Code E6 The occurrence of this code is an indicator of a malfunction caused by an overcurrent blocking of the air conditioning compressor motor.

H6 code

The appearance of this code indicates a malfunction associated with the lack of feedback from the fan motor.

With Gree air conditioners and split systems, repairs are easier than hi-fay models.

Self-diagnosis of Gree air conditioners

How can the average person ask this?

The explanation is simple Gree: codes. On Gree air conditioners and split systems, there are not many protection sensors. Those. everything is simplified.

  • Internal self-diagnostics of Gree air conditioners unified and almost identical in terms of error positions of inexpensive air conditioners, for example, such as Pioneer, General Climate, Lessar and others.

You will laugh, but for example, the catalog of Supra air conditioners has not even changed the name of the outdoor unit, perhaps there is not enough Photoshop skills, perhaps they did not consider it necessary.

In short, how were Supra air conditioners certified in Russia? It's a mystery to me. Supra catalog !! In fact. Heh ...

Self-diagnosis of Gree air conditioners is, -

  • high pressure protection,
  • protection against freezing of the evaporator,
  • Compressor overload protection,
  • Errors in switching the air conditioner during installation, confusing wires,
  • And errors in the temperature sensors of the evaporator and condenser.

All, you must agree not a lot. Gree, like an air conditioner, is simple in function, so there are not many error codes.
There are disadvantages of this simplification - these are weak varistors of the control board, insufficient smoothing

Error codes table, continued.

currents with voltage surges. A trifle, but this must be borne in mind when repairing air conditioners Gree and their analogues.

Example: country house. Leaving the dacha, the owners usually de-energize the building with a general switch.
Those. extinguished and everything, calmed down. We arrived ... They turned on the light with the same switch, and the air conditioner, refrigerator, or other Appliances does not work. Why? The answer is simple.

When the power is turned on with the load, current and voltage surges occur.

Varistors that smooth out voltage surges do not cope with the current load and burn out, burn well with smoke and soot, in the absence of a protective shell, as a rule, together with the fuse of the control board of the internal block of the split system.

There are "experts" who use wire when blowing a fuse. Can I do this? It is possible, but then, in addition to the varistors, the control board, the fan motor of the indoor unit will also burn out, and ... it rushed up to the compressor windings of the outdoor unit of the air conditioner.

Fireworks in the country. - Expensive renovation.

Troubleshooting and breakdowns of the air conditioner, Gree: as usual, we start the codes with ...

- refrigeration circuit malfunctions,

- malfunctions of the electrical part, electrical system. power supply and air conditioner control.
A source:

Error map, map drawing. Primary system diagnostics.

GREE Air conditioners for semi-industrial, industrial use, - error codes.

Error code = E1
Compressor, pressure surges (horn).

Error code = E2
Coil defective

Error code = E3
The air conditioner compressor has been triggered by low pressure(sound signal)

Error code = F0
Defective room temperature sensor.

Error code = F1
Wrong sensor resistance.

Error code = F2

  • The temperature sensor of the outdoor unit of the air conditioner has been triggered.

Error code = F3
The temperature sensor circuit is open.

GREE Split Air Conditioners Error Code ...

The cause of the malfunction, - the refrigerant system with a high degree of protection, - pressure.
code = E1

Gree LED blinks 1 time.
Indicator, - cooling =
Heating indicator =

The cause of Gree's malfunction is frost protection.
code = E2

Air conditioner start LED = LED blinks 2 times.
Indicator, - cooling =
Heating indicator =

Cause of malfunction - Compressor exhaust high temperature protection.
code = E4

Air conditioner start LED = blinks 4 times
Indicator, - cooling =
Heating indicator =

Cause of malfunction - AC overcurrent protection
code = E5

Air conditioner start LED = LED flashes 5 times
Indicator, - cooling =
Heating indicator =

The cause of the malfunction is a communication failure between the indoor unit of the air conditioner and the outdoor unit of the split system.
code = E6

Gree air conditioner start LED = blink 6 times
Indicator, - cooling =
Heating indicator =

Cause of malfunction, - Anti-high temperature protection
code = E8

Air conditioner start LED = blinks 8 times
Indicator, - cooling =
Heating indicator =

Cause of malfunction - No feedback of the internal fan motor
code = H6

Air conditioner start LED = flashes 11 times
Indicator, - cooling =
Heating indicator =

Cause of malfunction - Jumper cap is defective.
code = C5

Air conditioner start LED = flashes 15 times
Indicator, - cooling =
Heating indicator =

Cause of malfunction - Closed ambient sensor open, no contact or short circuit
code = F1

Indicator, - cooling = LED flashes 1 time
Heating indicator =

Name of sensor malfunction or breakage = Indoor tube open, no contact or short circuit
code = F2

Air conditioner start LED =
Indicator, - cooling = LED flashes 2 times
Heating indicator =

The cause of the malfunction - the outdoor ambient sensor is open, no contact or short circuit
code = F3

Air conditioner start LED =
Indicator, - cooling = LED flashes 3 times
Heating indicator =

Cause of malfunction - Outer tube sensor open, no contact or short circuit
code = F4

Air conditioner start LED =
Indicator, - cooling = blinks 4 times
Heating indicator =

Name = malfunction or breakage of the exhaust sensor open, no contact or short circuit
code = F5

Air conditioner start LED =
Indicator, - cooling = LED flashes 5 times
Heating indicator =

Cause of malfunction - Over load limit / underfrequency
code = F6

Air conditioner start LED =
Indicator - Cooling = Blink 6 times
Heating indicator =

Cause of malfunction - For limiting the current / output frequency
code = F8

Air conditioner start LED =
Indicator, - cooling = blinks 8 times
Heating indicator =

Cause of malfunction, - High exhaust gas temperature limit / frequency reduction
code = F9

Air conditioner start LED =
Indicator - cooling blink = 9 times
Heating indicator =

Cause of malfunction - Overvoltage protection for PN
code = PH

Air conditioner start LED =
Indicator, - cooling = flashes 11 times
Heating indicator =

The cause of the malfunction is the AC fault detection.
code = U5

Air conditioner start LED =
Indicator, - cooling = flashes 13 times
Heating indicator =

Cause of malfunction - Compressor reverse protection
code = U4

Air conditioner start LED =
Indicator, - cooling = blinks 14 times
Heating indicator =

Cause of malfunction, - For compressor phase current protection
code = P5

Air conditioner start LED =
Indicator, - cooling = flashes 15 times
Heating indicator =

The cause of the malfunction is the malfucntion input by the sensor tube
code = b5

Air conditioner start LED =
Indicator, - cooling = flashes 19 times
Heating indicator =

Cause of malfunction - Open DC fan motor is defective.
code = L3

Air conditioner start LED =
Indicator, - cooling = blinks 21 times
Heating indicator =

Cause of malfunction - Output malfunction or breakdown of the tube sensor
code = b7

Air conditioner start LED =
Indicator, - cooling = flash 22 times
Heating indicator =

Cause of malfunction, - Compressor overload sensor is defective.
code = FE

Air conditioner start LED =
Indicator, - cooling =
Heating indicator =

Cause of malfunction - Defrosting
code = h3

Air conditioner start LED =
Indicator, - cooling =
Heating indicator = LED flashes 1 time

Cause of malfunction - static protection against dust cleaning
code = H2

Air conditioner start LED =
Indicator, - cooling =
Heating indicator = LED flashes 2 times

Cause of malfunction - Compressor overload protection
code = H3

Air conditioner start LED =
Indicator, - cooling =
Heating indicator = LED flashes 3 times

Cause of malfunction - System abnormal protection
code = H4

Air conditioner start LED =
Indicator, - cooling =
Heating indicator = blinks 4 times

The cause of the malfunction, - IPM protection
code = H5

Air conditioner start LED =
Indicator, - cooling =
Heating indicator = LED flashes 5 times

Cause of malfunction - PFC protection
code = HC

Air conditioner start LED =
Indicator, - cooling =
Heating indicator = flashes 6 times

Cause of malfunction - Compressor step loss protection
code = H7

Air conditioner start LED =
Indicator, - cooling =
Heating indicator flash = 7 times

Cause of malfunction - Heating against high frequencies temperature drop
code = HO

Air conditioner start LED =
Indicator, - cooling =
Heating indicator = flashes 10 times

Cause of malfunction - Startup failure
code = Lc

Air conditioner start LED =
Indicator, - cooling =
Heating indicator = flashes 11 times

Cause of malfunction - Compressor for phase failure protection
code = U2

Air conditioner start LED =
Indicator, - cooling =
Heating indicator = flashes 12 times

Cause of malfunction - Phase current compressor is defective.
code = U1

Air conditioner start LED =
Indicator, - cooling =
Heating indicator = flashes 13 times

Cause of malfunction - Compressor demagnetization protection
code = HE

Air conditioner start LED =
Indicator, - cooling =
Heating indicator = flashes 14 times

Cause of malfunction - EEPROM download is defective.
code = EE

Air conditioner start LED =
Indicator, - cooling =
Heating indicator = flashes 15 times

The cause of the malfunction is a communication failure between the motherboard and the driver of the board
code = P6

Air conditioner start LED =
Indicator, - cooling =
Heating indicator = flashes 16 times

The cause of the malfunction is a malfunction of the charge capacitor
code = PU

Air conditioner start LED =
Indicator, - cooling =
Heating indicator = flashes 17 times

The cause of the malfunction, - the sensor circuit IPM is faulty.
code = P7

Air conditioner start LED =
Indicator, - cooling =
Heating indicator = flashes 18 times

The cause of the malfunction, - IPM high-temperature protection
code = P8

Air conditioner start LED =
Indicator, - cooling =
Heating indicator = flashes 19 times

Cause of malfunction - PN protection voltage drop
code = U3

Air conditioner start LED =
Indicator, - cooling = blinks 20 times
Heating indicator =

The cause of the malfunction is low protection voltage PN
code = PL

Air conditioner start LED =
Indicator, - cooling =
Heating indicator = flashes 21 times

Cause of malfunction, - Current detection circuit is defective. Or malfunction or breakage of current sensor
code = Pc

Air conditioner start LED =
Indicator, - cooling =
Heating indicator =

Cause of malfunction - Compressor phase failure protection
code = Ld

Air conditioner start LED =
Indicator, - cooling =
Heating indicator =

Cause of malfunction - Compressor or rotary protection blocked
code = LE

Air conditioner start LED =
Indicator, - cooling =
Heating indicator =

The cause of the malfunction, - IPM is more than the temperature limit / frequency decrease
code = EU

Air conditioner start LED =
Indicator, - cooling =
Heating indicator =

Cause of malfunction - 4-way reversal valve abnormal
code = U7

Air conditioner start LED =
Indicator, - cooling =
Heating indicator =

The cause of the malfunction is the disconnection of the exhaust gas temperature sensor
code = U8

Air conditioner start LED =
Indicator, - cooling =
Heating indicator =

Cause of malfunction - AC zero voltage error detection
code = U9

Air conditioner start LED =
Indicator, - cooling =
Heating indicator =

Cause of malfunction, - Frequency temperature drop for the tube
code = FA

Air conditioner start LED =
Indicator, - cooling =
Heating indicator =

Cause of malfunction - Anti-freezing limit / frequency reduction
code = FH

Air conditioner start LED =
Indicator, - cooling =
Heating indicator =

Models: air conditioner repair brands KFR-32GW / BP, KFR-45LW / D, KFR-3502GW / BP, KFR-2501GW, KFR-45LW, KFR-3301GW, KFR-3201GWCPU, KFR-2608GW / BP and other KFR series, PDF fail.