The lineup air handling units with a capacity of 1200 - 100,000 cubic meters / h, consisting of 14 standard sizes, ranging from 1200 cubic meters / h to 100,000 cubic meters / h. VTS settings Ventus VS 21-650 are designed for ventilation systems in the temperature range from -40 ° C to + 60 ° C. Air handling units with a rotary recuperator or with an intermediate heat carrier (glycolic). Designed to be placed both indoors and outdoors. Post mounting (VS 21-150) and steel frame (VS 180-650). Service access from the side.
To select a VTS ventilation unit, call Center Vent and get detailed advice. The delivery set of the ventilation unit includes the selected sections, automation, sensors, automation panel. Minimum equipment: electrically driven ventilation section, air valve, automation, flexible connection. Disassembled delivery. Collection and installation of the ventilation unit at the location. In some cases, complete delivery is possible (negotiated individually).
Ventilation VTS installations Ventus VS 21-650 are equipped with one or more units, which are marked on the inspection panels. Frameless heat-insulated housing. Service access is through the unit panels on the side of the unit. Ventus VS air handling units and central air conditioners are not only the units themselves. It is also a set of carefully designed and stitched automation devices for control and monitoring, allowing convenient and stable control of the operation of ventilation and air conditioning systems.
The software control algorithms were created with the intention of minimizing the consumption of energy carriers while ensuring the necessary parameters of the processed air, as well as eliminating abnormal conditions.
Automation. There is a possibility of a simplified automation system for local regulation, and an automation system that can be integrated with external monitoring and control systems. There is a full set of sensors, electronic regulators, as well as control panels.
Technical characteristics of ventilation units VTS Ventus
Model | Air consumption, m3 / hour | Dimensions, mm | Weight, kg |
VTS Clima Ventus VS-21-R-H | 3080 | 1490x488x961 | 129 |
VTS Clima Ventus VS-30-R-H | 4322 | 1490x620x961 | 145 |
VTS Clima Ventus VS-40-R-H | 5661 | 1490x620x1168 | 167 |
VTS Clima Ventus VS-55-R-H | 8216 | 1856x755x1339 | 227 |
VTS Clima Ventus VS-75-R-H | 11379 | 1856x875x1480 | 273 |
VTS Clima Ventus VS-100-R-H | 13550 | 2221x975x1660 | 356 |
VTS Clima Ventus VS-120-R-H | 18079 | 2221x1012x1891 | 406 |
VTS Clima Ventus VS-150-R-H | 22420 | 2221x1113x2085 | 443 |
VTS Clima Ventus VS-180-R-H | 27220 | 2221x1357x2085 | 662 |
VTS Clima Ventus VS-230-R-H | 33460 | 2221x1357x2493 | 763 |
VTS Clima Ventus VS-300-R-H | 44760 | 2587x1656x2585 | 1003 |
VTS Clima Ventus VS-400-R-H | 60501 | 2587x1889x3085 | 1196 |
VTS Clima Ventus VS-500-R-H | 74350 | 2953x1889x3585 | 1484 |
VTS Clima Ventus VS-650-R-H | 98500 | 3318x2366x3697 | 1753 |
VTS Clima Ventus VS-21-R-С | 2200 | 1490x488x961 | 132 |
VTS Clima Ventus VS-30-R-С | 3100 | 1490x620x961 | 144 |
VTS Clima Ventus VS-40-R-С | 4100 | 1490x620x1168 | 181 |
VTS Clima Ventus VS-55-R-С | 6054 | 1856x755x1339 | 228 |
VTS Clima Ventus VS-75-R-С | 8150 | 1856x875x1480 | 170 |
VTS Clima Ventus VS-100-R-С | 10700 | 2221x975x1660 | 347 |
VTS Clima Ventus VS-120-R-С | 13300 | 2221x1012x1891 | 385 |
VTS Clima Ventus VS-150-R-С | 16400 | 2221x1113x2085 | 448 |
VTS Clima Ventus VS-180-R-С | 19900 | 2221x1357x2085 | 613 |
VTS Clima Ventus VS-230-R-С | 24600 | 2221x1357x2493 | 770 |
VTS Clima Ventus VS-300-R-C | 32900 | 2587x1656x2585 | 911 |
VTS Clima Ventus VS-400-R-С | 44500 | 2587x1889x3085 | 1174 |
VTS Clima Ventus VS-500-R-С | 54000 | 2953x1889x3585 | 1395 |
VTS Clima Ventus VS-650-R-С | 71400 | 3318x2366x3697 | 1686 |
VTS Clima Ventus VS-21-R-CH | 2200 | 1856x488x961 | 157 |
VTS Clima Ventus VS-30-R-CH | 3100 | 1856x620x961 | 171 |
VTS Clima Ventus VS-40-R-CH | 4100 | 1856x620x1168 | 212 |
VTS Clima Ventus VS-55-R-CH | 6054 | 2221x755x1339 | 274 |
VTS Clima Ventus VS-75-R-CH | 8150 | 2221x875x1480 | 326 |
VTS Clima Ventus VS-100-R-CH | 10700 | 2587x975x1660 | 404 |
VTS Clima Ventus VS-120-R-СH | 13300 | 2587x1012x1891 | 449 |
VTS Clima Ventus VS-150-R-CH | 16400 | 2587x1113x2085 | 522 |
VTS Clima Ventus VS-180-R-CH | 19900 | 2587x1357x2085 | 712 |
VTS Clima Ventus VS-230-R-CH | 24600 | 2587x1357x2493 | 904 |
VTS Clima Ventus VS-300-R-CH | 32900 | 2953x1656x2585 | 1070 |
VTS Clima Ventus VS-400-R-CH | 44500 | 2953x1889x3085 | 1413 |
VTS Clima Ventus VS-500-R-CH | 54000 | 3318x1889x3585 | 1610 |
VTS Clima Ventus VS-650-R-CH | 71400 | 3684x2366x3697 | 2003 |
VTS Clima Ventus VS-21-R-PСH | 2200 | 3318x488x961 | 433 |
VTS Clima Ventus VS-30-R-PСH | 3100 | 3318x620x961 | 480 |
VTS Clima Ventus VS-40-R-PСH | 4100 | 3318x620x1168 | 571 |
VTS Clima Ventus VS-55-R-PСH | 6054 | 4050x755x1339 | 771 |
VTS Clima Ventus VS-75-R-PСH | 8150 | 4050x875x1480 | 914 |
VTS Clima Ventus VS-100-R-PСH | 10700 | 4415x975x1660 | 1097 |
VTS Clima Ventus VS-120-R-PСH | 13300 | 4415x1012x1891 | 1232 |
VTS Clima Ventus VS-150-R-PСH | 16400 | 4781x1113x2085 | 1510 |
VTS Clima Ventus VS-180-R-PСH | 19900 | 4781x1357x2085 | 2053 |
VTS Clima Ventus VS-230-R-PСH | 24600 | 4781x1357x2493 | 2366 |
VTS Clima Ventus VS-300-R-PСH | 32900 | 5878x1656x2585 | 3066 |
VTS Clima Ventus VS-400-R-PСH | 44500 | 5878x1889x3085 | 3968 |
VTS Clima Ventus VS-500-R-PСH | 54000 | 6244x1889x3585 | 4548 |
VTS Clima Ventus VS-650-R-PСH | 71400 | 7341x2366x3697 | 5988 |
Using Newest technologies and innovative engineering solutions, our company has developed unique VTS Clima units. Many years of experience helps us to manufacture plants that fully meet the requirements. modern market... Supply and exhaust and supply systems VTS is a reliable energy-saving equipment, the main functions of which are:
The units are designed to work with outside air in the temperature range from -40 to +60 ° C. Air handling units VTS are manufactured without heat recovery and with rotary and cross-flow recuperators. Systems with a mixing chamber and / or glycol circuit operate with outdoor air of at least -50 ° C, provided that the temperature in the room where they are located does not fall below this mark. For a VTS unit with a rotary recuperator, the air temperature must not fall below -30 ° C.
It is important to note that PTC installations are not just machines. They include a set of carefully selected and programmed automation applications for control and monitoring that allow you to regulate the operation of ventilation and air conditioning systems. The used supply control algorithms exhaust units VTS Clima was developed to minimize operating costs while maintaining the required parameters of the incoming air, as well as to reduce the likelihood of emergencies.
A feature of MTC equipment is the ability to universal application due to a wide range of functional elements. For example, it is successfully used in both subtropical and arctic climates. Whether it is an office in Dubai, a plant in Siberia or a shopping center in Budapest, Ventus ventilation units work flawlessly, providing comfort in any climatic zone.
Note that the capabilities of the VTS VS air handling unit have been significantly expanded due to the presence of an adiabatic air humidification section. You can get acquainted with more detailed information about VTS Clima units on our official website. Here is a catalog with complete model range VTS installations, the price of which depends on individual technical features.
We invite you to familiarize yourself with the range of VTS Clima ventilation units. This section of the catalog presents duct supply, suspended supply and exhaust and floor air handling units. Each type has its own characteristics and advantages, so you will have a lot to choose from.
VTS Clima ventilation units - advantages
Ventilation units from this brand have a whole set of significant advantages, which include lightweight, but solid construction(frameless housing), good noise absorption, high energy recovery rate (up to 85%), the presence of highly efficient PLUG-fans.
An assortment of standard sizes, from suspended compact units to overall ones designed for high air flow rates, and a wide selection of sections that perform all air handling functions - all this allows you to choose the necessary unit that is suitable for a given room with the required microclimate parameters.
Smart Trading presents all models of VTS Clima air handling units. Our qualified specialists will provide advice on the selection of the installation and help you make the right choice.
Air handling units and central air conditioners VENTUS are designed to supply rooms up to 100,000 m3 / h of heated or 70,000 m3 / h of cooled air. In both cases, heat recovery units can be installed in the air handling unit: recuperative with a cross-type heat exchanger or a rotating regenerator, allowing to recover up to 85% of the energy.
The size range of 16 sizes allows you to choose an air handling unit that best suits the needs of a particular facility in terms of capital investment and operating costs. The new VENTUS range is optimized for overall dimensions units and made more convenient for placement in a variety of rooms.
The first two standard sizes of 16 VENTUS (VS10 and VS15) belong to the group of small-sized, "suspended" air handling units. Thanks to the use by VTS modern materials and accessories, VENTUS air handling units are so compact and light that they can be mounted in a suspended position and more powerful machines up to size VS150, which have a capacity of up to 18,000 m3 / h.
Suspended air handling units of the first standard size operating in the range of 1000 - 1500 m3 / h have a height of only 36 cm. Air handling units VENTUS with a capacity of up to 15 000 m3 / h can be installed in standard rooms with a height of up to 2.6 m Similar, but more powerful machines with air supply up to 25,000 m3 / h can be placed in rooms with a height of 3.2 m (EU standard).
The new VENTUS air handling units by VTS for ventilation and air conditioning systems include units for outdoor installation in the open air, as before, but the decrease in the height of the new equipment made the unit “flatter”, lowered the center of gravity and reduced the “windage” of the case.
The casing panels of the VENTUS air handling unit are made of two galvanized steel sheets, outer sheet covered with an additional anti-corrosion layer. The inner filling of the panel is a layer of polyurethane foam. This design of the casing allows the use of air handling units in various climatic zones (from -40 C to +70 C). The special design of the locks - labyrinths connecting the individual blocks of the case, increases the strength and tightness of the system.
Air handling units VENTUS are designed to save energy consumption of ventilation and air conditioning systems, which allows to reduce operating costs, in some cases, by 35%. The use in VENTUS air handling units of a new fan group with a frequency converter and a caseless fan of a new improved design also led to a decrease in power consumption. Increased efficiency of these fans, reduced acoustic noise- all this characterizes the new VENTUS air handling units.
The automatic control, regulation and monitoring system developed by VTS for VENTUS air handling units has a freely programmable controller from the SIEMENS concern, specially designed for ventilation and air conditioning systems.
The automation kit has a connector for connecting an external small-sized control panel. An external remote control of the automation system allows you to easily and quickly read and set the required operating parameters of the VENTUS unit.
In addition, the operating parameters of the unit can be set and controlled using a personal computer with a standard RS-232 port. The automation kit can be integrated with a building management system (BMS) based on the most common LON standard. VTS air handling units are certified by Rostest, Hygienic certificate, Eurovent, ISO 9001-14001, CE, TUV. VTS provides a 3-year warranty for VENTUS air handling units.
Attention! To receive a commercial proposal, the order must indicate:
1. Name / purpose of the object.
2. The address of the object.
3. The name of the company specified in project documentation(who made the project).
If there is no information about the object, indicate:
Or fill out the questionnaire: