Characteristics
Wall-mounted gas double boiler Kiturami twin. Alpha 13 with a closed combustion chamber is intended for heating and GVS of private houses, cottages and other residential premises with an area of \u200b\u200bup to 150 m2. Combines the advantages of cumulative boilers, as well as boilers with the possibility of instant heating. The heating circuit is a new type of clean copper dual heat exchanger to increase thermal conductivity in high-temperature parts and from aluminum, which is used in low-temperature parts in order to prevent corrosion and extend the service life. And the heat exchanger of the DHW built into expansion tankallows you to get continuous feed hot water. Energy saving is achieved thanks efficient work The boiler equipped with a room thermostat-regulator with a digital display of "Sleep" modes, "No", "Shower". During standby mode, energy consumption is less than 1 W. In the event of a malfunction, the control light flashes, and a digit indicates the type of malfunction appears on the indoor thermostat display. This makes it easy to establish the cause of the reality. Kiturami Twin Alpha boilers are available with two types of smoke removal system: by the Korean version (Koreatype Ø 75/100 mm - the output side) and by the European version (COAXIAL Ø 60/100 mm - the output to any side).
Features
Specifications
Gas boiler type
Method of fastening Wall
Type of combustion chamber Closed
Thermal power, kW 15.1
Yes
Yes
Natural gas Yes
Liquefied gas yes
75/100 (60/100)
Copper + aluminum
Manufacturer South Korea
Gas boiler type
Convection principle
Number of contours dualcononturic
Method of fastening Wall
Type of combustion chamber Closed
Thermal power, kW 15.1
Built-in expansion tank Yes
Built-in circulation pump Yes
Natural gas Yes
Liquefied gas yes
Diameter coaxial chimney, mm 75/100 (60/100)
Material of the primary heat exchanger Copper + aluminum
Manufacturer South Korea
Gas inlet, mm 15
Log in / out of DHW, mm 15
Log in / out Heating, mm 20
Efficiency (GVS),% 91.4
Efficiency (heating),% 91.2
Maximum temperature in heating circuit, ° C 85
Circulation method in the heating circuit Forced circulation
Productivity of DHW at Δt \u003d 30 ° C, l / min 7.2
Working pressure in the circuit of DHW, kg * C / cm2 0,2 - 6
Operating pressure in the heating circuit, kg * C / cm2 2.5
Gas consumption, kW 19.2
Gas consumption, kg / h 1.38
Gas consumption, kcal / h 16.5
W x x in, mm 430x210x730
Voltage, in 220
Frequency, Hz 50
Weight, kg 26.3
High reliability
When the gas or carbon monoxide leakage is detected, the built-in gas leakage sensor automatically stops the operation of the boiler by the twin alpha 13, and displays gas through the air vent pipe, and also displays the gas leakage error code on the room thermostat. The built-in seismic switch works with strong jokes in 4-5 points and turns off the boiler, thereby preventing secondary damage
Installation
Our company's specialists carry out a paid departure to the object, while the cost of the departure is returned at the conclusion of the contract, in place will agree with the timing, stages and volumes of work, select equipment and components.
After the conclusion of the contract and making a prepayment, the assigned period is supplied and installation and commissioning of equipment. Upon completion of work, acts are drawn up and full payment is made.
With prices for the departure of the specialist and the installation of equipment can be found on the link.
Service and repair
At your request, the company is ready to conclude an agreement with you for the annual service maintenance. The advantage is an extended warranty on the work performed and the preferential service of the equipment.
If such a contract is not concluded, you can contact the profile service cents by reference.
Buy Copper Gas wall-mounted two-round twin alpha with forced circulation of coolant with a closed combustion chamber can be for heating residential and non-hazardous production premisesas well as for hot water supply.
Main characteristics
Series - Twin Alpha
Model - Twin Alpha 13
Maximum thermal power - 15.1 kW
Type - Gas, convection
Fuel - natural gas, liquefied gas
Gas stove
Camera combustion - closed
The number of contours - double-circuit
Installation - Wall Mural
Heated area - up to 150 sq.m
KPD - 91.2%
Productivity of hot water at Δt \u003d 25 ° C - 10.7 l / min
Max. The temperature of the coolant - 80 ° C
Network voltage - single-phase
Weight - 26.3 kg
Diameter of chimney (in / out) - 100/60 mm
Sizes (VCHHHH) - 430x210x730 mm
Temperature - 35 - 60
Electronic control
Connect Twin Alpha 13
Gas connection diameter - 1/2 "
Diameter of connection circuit DHW - 1/2 "
Heating Contour Connection Diameter - 3/4 "
Max. Water pressure in the DHW circuit - 6 bar
Max. Water pressure in heating circuit - 3 bar
Comfort
Functions - Inclusion Indicator, Thermometer, Auto), Room thermostat, Programmer
Features - Display, Remote Control
Safety
Protection - Autodiagnostic, Gas Control, Overheating Protection, Performance Prevention Mode, Air Sweet
Additionally
Built-in expansion tank 7 l
Built-in circulation pump
1. Copper twin alpha - 1
2. Control panel STR-5900 - 1
3. Adapter coaxial chimney - 1
4. Set of fastening elements - 1
5. Operation Manual - 1
6. Packaging - 1
Wall mounted gas boilers Kiturami Twin Alpha, Boilers based on model Rowwho scored the popularity of WORLD 5000 boilers. They are not only economical, but also very effective. Here is a rare function as an instantaneous supply of hot water prepared. Having installed such a boiler in her house, you can not worry about the fact that when the crane is discovered from it flows cold water. The heart of the boilers of the Kiturami Twin Alpha model row is dual copper-aluminum heat exchanger. Distinctive features and advantages:
Double-circuit gas boilers Kiturami. Twin Alpha is endowed with the unique opportunity to quickly prepare hot water, which is far from every heating equipment. The heart of this model range is a dual heat exchanger made of copper and aluminum. This design allows not only to increase the efficiency, but also protect the heat exchanger itself from corrosion. At the same time, the efficiency of the efficiency in both circuits reaches 93%.
The manufacturer has worked not only over the high efficiency, but also over the power consumption of wall double-circuit boilers Kiturami Twin Alpha. Being in standby mode, they consume maximum 1 watt of electricity. In addition to increasing the cost-effectiveness, specialists from Kiturami took care of the lower noise level. The system uses a low-noise fan installed on a special platform that reduces possible vibrations. As a result wall boilers Kiturami twin Alpha have an attractive low noise level.
Contemporary wall boilers Kiturami Twin Alpha are endowed with simple and reliable design. Durable heat exchanger, expansion tank made of lightweight materials, gas consumption tracking system - all this not only increases efficiency, but also contributes to more economical fuel expenditure. If necessary, the boiler can be installed in the "absence" or "sleep" modes, as a result of which it will consume minimum gas and electricity.
Per safe job Wall heating boilers Kiturami Twin Alpha meet advanced security systems. First of all, these boilers are distinguished by the presence of an advanced gas leakage control system. The slightest leaks instantly cause the equipment stop. An earthquake detection system works in a similar way - the gas supply automatically stops when the seismacor is triggered. Boilers are able to prevent the freezing of the circulation pump and the whole heating system In general, including heating the coolant with a strong decrease in temperature. Also Kiturami Twin Alpha boilers are monitored for the presence of power, behind the heat exchanger temperature, gas pressure and traction.
Wine control two-circuit boilers Kiturami Twin Alpha is carried out using a digital control panel. It allows you to exhibit right mode Work, adjust the temperature of the hot water prepared by hot water. The display of error codes is provided, which greatly facilitates the diagnostics of the breakdown.
Kiturami twin alpha boilers possess closed cameras Combustion and most often exploited in private homes, cottages and apartments. Capacity range - from 15.1 to 34.8 kW. It is allowed to operate boilers under reduced gas pressure.
Detailed description of goods
Main characteristics
Twin Alpha series TWIN ALPHA 20 Max. Heat capacity 23.3 kW Type Gas, convection fuel Natural gas, liquefied gas Burner Gas combustion chamber Closed number of contours Two-circuit installation Wall heated area 230 sq. M DPD 91.8% Hot water performance at T 30 ° C 11.1 l / min Max. The temperature of the coolant 80 ° C network voltage is single-phase weight 26.9 kg Connecting a separate chimney (diameter 80 mm) Yes Sizes (SCHWH) 430x730x210 mm Temperature 35 - 60 Electronic control
Connection
Gas connection nozzle 1/2 "Contour connection nozzle DHW 1/2" nozzle connection Contour of heating 3/4 "Max. Water pressure in the circuit of GVS 6 bar Max. Water pressure in the heating circuit 3 bar Diameter coaxial chimney 60/100 mm
Functions Inclusion indicator, thermometer, auto-shirt, room thermostat, programmer Features display, remote control
Safety
Protection of autodiagnostics, gas control, overheating protection, freezing prevention mode, air vent
Additionally
Built-in expansion tank 7 l Built circulation pump yes
Kiturami Twin Alpha 20 convection gas boiler has wall variant Installations. The design of its heat exchanger combines the advantages of the accumulative modification units of instantaneous heating technology. It is this feature that the high efficiency of the system reaching 93% is explained. With all this, the model refers to the number of ultra economical equipment: when switching to standby mode, energy costs are less than 1 W.
The boiler with a ventilation type of burner is used as a work fuel uses natural gas. The use of a steel spiral heat exchanger for the production of hot water made it possible to increase the efficiency of the device 7 times, compared with a simple plate analogue, which was taken as the basis in the previous series heating equipment. Turbated chimney is located in the center of the unit, which simplifies mounting work, and the plug-in can be displayed as in leftand right. The operation of the two-circuit heat exchanger is based on the electronic type of ignition.
The heat supply capacity of the installation of 23.3 kW allows you to qualitatively damop the premises with a total area of \u200b\u200bup to 233 square meters. m. The design weighing 28 kg contains an expansion tank of 7 liters. Thanks to new constructive solutions, Kiturami Twin Alpha 20 is more resistant to network power supply. The heat exchanger is made in the format "dual type": its high-temperature parts are made of copper, and low-temperature - from aluminum, which prevents unfavorable corrosion processes, extending the life of the boiler equipment.
The boiler is equipped with a new fan, which gives low operating noise indicators by maintaining the required pressure in stable mode.
The control of the heating unit is operated through the CTR-5700Plus thermostat-regulator. The user will be available to the following options:
The built-in self-diagnostic system has the following set of functions:
Wall-mounted Gas boiler Kiturami Twin Alpha 30 For heating and with the possibility of instantaneous hot water supply. Kiturami Twin Alpha coincide the advantages of cumulative type boilers, as well as boilers type technologies with the possibility of instant heating. This achieves high efficiency. A new type of dual heat exchanger was installed, made of pure copper for better thermal conductivity in high-temperature parts and aluminum, which is used in low-temperature parts in order to prevent corrosion and extend life. Kiturami Twin Alpha is very economical boilers. During standby mode, energy consumption is less than 1 W.
Features:
We ask you to pay attention: Kiturami Twin Alpha boilers are produced with two types of smoke farming systems along the Korean version (Koreatype Ø 75/100 mm - the output side) and by the European version (COAXIAL Ø 60/100 mm - output to any side).
Specifications | |
Brand | Kiturami. |
Country assembly | South Korea |
Type of boiler | gas |
Number of contours | double-circuit |
The combustion chamber | closed |
Type of fuel | Liquefied gas, natural gas |
Installation | natural |
Heated Square | 340 sq. M. m. |
Power | 34.8 kW |
Efficiency% | 91.8 |
Control | electronic display |
Country of manufacture | South Korea |
Condensation | Not |
Non-volatile | Not |
Material of the primary heat exchanger | copper |
Material of the secondary heat exchanger | stainless steel |
Built-in circulation pump | Yes |
Built-in expansion tank | Yes |
Natural gas consumption cube. m / hour | 3.17 |
Nominal pressure of natural gas, mbar | 13 |
Coolant temperature, ° С | 45 - 80 |
Temperature in the DHW circuit, ° C | 35 - 60 |
Productivity hot water at T 30 ° C, l / min | 16.7 |
Max. water pressure in the DHW circuit, bar | 6 |
Max. water pressure in heating circuit, bar | 3 |
Color | white |
Comfort | |
Functions | inclusion indicator, thermometer, auto-shirt, room thermostat, programmer |
Features | display, remote control |
Safety | |
Protection | autodiagnostic, gas control, overheating protection, freezing prevention mode, air vent |
Connection and overall dimensions | |
Overall size | 486 × 730 × 210 mm |
Diameter of coaxial chimney | 75/100 mm |
Weight | 29.6 kg |
DHW circuit connections | 1/2" |
Heating Contour Connection Pipe | 3/4" |
Gas connection nozzle | 1/2" |