There are two types of water heaters: flowing water heaters and cumulative water heaters. Flowing water heaters allow hot water almost instantly, however, they are characterized by a large current (power), which is not always allowed for the existing wiring. Current water heaters consume much less power, while water heating in the tank takes some time. The complex of characteristics and experience is established that precisely the accumulative water heaters, heating water using the greatest demand.
Cumulative electric water heaters Consist of sealed (most often steel) tank, and a heating element of a TEN, which is located inside the tank of the water heater. Water in cumulative water heaters is heated to the required temperature using the heating element, while it is used relatively not high power. Inside the accumulative water heater, water coming from the water supply system is constantly heated to the required temperature and maintained during its operation. The advantage of accumulative water heaters is due to the fact that hot water can be distributed as needed by several waterproof points at the same time. For example: the use of an electric cumulative water heater in the bathroom and in the kitchen.
Water heaters Electric flowing type WPP are stationary electric heating devices designed to heat the flow water for technological and sanitary and hygienic needs at the enterprises of industry, agriculture, in everyday life, etc.
Marking of flow water heaters WEP
VEP-X UHL4:
WEP - Electric flow water heater;
X - water heater power, kW;
UHL4 - climatic performance and placement category according to GOST 15150-69. No. According to the method of protecting a person from electric shock, the water heater refers to the I class according to GOST 27570.0-87, has a splashing performance.
Water heaters correspond to TU 34 4245-400 NGOs "C" -959 / 95-5-92.
Water heater flowing is a design consisting of a steel tank enclosed in the casing. In the top of the tank there is a temperature sensor. At the bottom of the tank of the flow water heater, the heating unit is fixed. A safety valve is installed on the cold water supply pipe. It combines three valves in itself: the safety valve opens the water discharge hole to the outward when the pressure in the tank increases to (0.67 + 0.03) MPa; check valve, through which water enters the tank, but cannot flow from it, if the pressure disappeared in the supply water supply; The overflow valve opens the output of the water from the tank into the supply line of the supply water supply in the case when the pressure in the tank exceeds the water supply pressure by 0.07 MPa. The valve reduces the pressure in the tank during water heating. The arrow on the body of the safety valve indicates the direction of water supply to the heater.
In the control cabinet of the electric flow water heater, there are a magnetic starter, switching electric heaters, which allow stepwise to change the power consumption of 1/3, 2/2, 1 from the nominal; a fuse protecting the control circuit from the KZ; Automatic switches protecting the device from electromagnetic and thermal overloads.
As a temperature sensor, the temperature sensor TAD101-1, tuned to the temperature (75 + 5) degree, is used as a temperature sensor for water. C, it automatically shuts off the heating elements from the power supply and again includes them when cooled water. If desired, the water temperature can be set from 30 to 90 degrees. FROM.
The package of water heater of the flow electricity includes: flowing water heater; control cabinet; A set of spare parts and accessories (seal - 6 pcs., Fuse VP1-1-0.5 A, instruction manual).
Electric boilers WEO are designed for heating residential houses, recreation centers, public, industrial and agricultural premises, as well as other premises equipped with water heating system. Distinctive features: In the heating mode, the boilers automatically track the predetermined air temperature in the heated room.
Electric boilers WEO work offline, protected from overheating, increase water pressure, consumes the minimum of electricity.
Electric boilers may not be the most popular means of heating the premises and, most likely, will not be able to withstand competition with gas boilerBut it may well compete with boilers on liquid fuel. Electric boilers are easy to install, operate, compact, and do not require additional equipmentSafe and are an environmentally friendly source of heat, as they do not have emissions into the atmosphere.
Specifications Wao heating water heaters can be viewed in our price list to water heaters.
Our company offers accumulative water heaters of the production of "Termex", flow water heaters of the VEP type, as well as water heaters (boilers) for heating of WEO type.
Production of TEN is produced.
Large assortment of room heaters.
With assortment and technical characteristics you can find on the site page:
Main characteristics
Industrial flowing water heater VEP-6M is required to heat the flow water used on sanitary and technological needs. This stationary electric heating device can be used in catering establishments (for example, for washing dishes), in kindergartens, schools, polyclinics - in any institution, in which it is necessary to constantly have hot water.
You can purchase model VEP-6M directly on our website. To order an order, click on the "Buy" button below the product, then specify the preferred payment form (
Water heaters Electric flowing type WEP are stationary electric heating devices designed to heat the flow water at the enterprises of industry, agriculture, in everyday life, etc.
Water heater electric type WEP consists of a water heater, control cabinet and safety valve.
The water heater is a design consisting of a steel tank enclosed in the casing. In the top of the tank, the sensor is installed (sensor) The thermographer 75 ± 5ºС, it automatically shuts off the heating elements from the electrical network and again includes them when the water is cooled. As an emergency thermal switch, a sensor without self-radiant is used, tuned to a temperature of 93 ± 5ºС. At the bottom of the tank is fixed the heating unit. A safety valve is installed on the cold water supply pipe. It combines a safety valve that opens the water relief hole to outward when the pressure in the tank increases to 0.6 MPa and the reverse valve, through which water goes into the tank, but cannot flow from it, if the pressure disappeared from it. The arrow on the body of the safety valve indicates the direction of water supply to the heater.
In the control cabinet are located:
- magnetic starter, commuting electric heaters;
- a fuse that protects the chain of control from short circuit;
- Automatic switches, allow steady to change the power consumed in the ratio from the nominal.
VEP- | 6m | 6 | 9 | 12 | 15 | |
Rated power, kW | 6 | 6 | 9 | 12 | 15 | |
Rated voltage in | 220 | 380 | 380 | 380 | 380 | |
Max.t heated water, ºС | 85 ± 5. | |||||
Productivity PR Heating water to the difference in temperatures 30, ºС l / h | 110 | 165 | 260 | 335 | 415 | |
Performance PR Heating water to the difference in temperatures 70, ºС l / h | 47 | 85 | 110 | 140 | 175 | |
Water heater capacity, l | 6 | 12,5 | 12,5 | 12,5 | 12,5 | |
Mass, kg. | 12 | 18 | 18 | 18 | 18 | |
Dimensions, mm Control Cabinet | 240*140*270 | |||||
Dimensions, water heater sizes, mm | 475*220*240 | 600*290*260 |
Water heaters are stationary electric heating devices designed to heat the flow water at the enterprises of industry, agriculture, in everyday life, etc. VEP-X UHL4:
WEP - Electric flow water heater;
X - water heater power, kW;
UHL4 - climatic performance and category of placement on GOST
15150-69. No. According to the method of protecting a person from electric shock, the water heater refers to the I class according to GOST 27570.0-87, has a splashing performance.
Water heaters correspond to TU 34 4245-400 NGOs "C" -959 / 95-5-92.
TU 34 4245-400 NGO "C" -959 / 95-5-92
Technical data of water heaters are shown in the table.
Name of parameter | Parameter value for type water heaters | ||||
VEP-4. | VEP-6. | VEP-9. | VEP-12. | VEP-15. | |
Rated power, kW | 4 | 6 | 9 | 12 | 15 |
Rated voltage in | 220 | 380 | |||
Heat production, kcal / h, not less | 3100 | 4700 | 7396 | 9400 | 11740 |
Performance, DM 3 / h, when heating flow water to: | 110 | 165 | 260 | 335 | 415 |
Current frequency, Hz | 50 | ||||
Maximum temperature of heated water, ° С | 75 ± 5. | ||||
Water heater tank capacity, DM 3 | 6 | 12 | |||
Overall dimensions, mm, no more | 220 ? 240 ? 475 | 260 ? 290 ? 540 |
|||
cabinet control | 290 ? 270 ? 140 | ||||
Water heater mass, kg | 12 | 18 | |||
Average service life, years, not less | 4 |
Water heater of the WPP type (Figure) consists of a water heater and control cabinet.
The water heater is a design consisting of a steel tank enclosed in the casing. In the top of the tank there is a temperature sensor. At the bottom of the tank is fixed the heating unit. A safety valve is installed on the cold water supply pipe. It combines three valves in itself: the safety valve opens the water discharge hole to the outward when the pressure in the tank increases to (0.67 + 0.03) MPa; The check valve through which the water enters the tank, but cannot flow from it, if the pressure disappeared in the supply water supply; The overflow valve opens the output of the water from the tank into the supply line of the supply water supply in the case when the pressure in the tank exceeds the water supply pressure by 0.07 MPa. The valve reduces the pressure in the tank during water heating. The arrow on the body of the safety valve indicates the direction of water supply to the heater.
In the control cabinet are located: a magnetic starter, switching electric heaters, which allow stepwise to change the power consumption 1/3, 2/2, 1 from the nominal;
a fuse protecting the control circuit from the KZ; Automatic switches protecting the device from electromagnetic and thermal overloads.
A sensor-relay sensor TAD101-1, tuned to the temperature (75 + 5) ° C, which is automatically disconnected by the heating elements from the power supply, is used as a temperature sensor for water. If desired, the temperature of the water can be set from 30 to 90 ° C.
The package includes: water heater; control cabinet;
a set of spare parts and accessories (seal - 6 pcs., Fuse VP1-1-0.5 A, instruction manual).
Hot water today is a granted business. With its absence, there is a huge inconvenience and a sense of density from civilization. In the country or in a private house, it is not always possible to bring central hot water supply, and in the same way in apartments with convenience, it gives a failure. But progress, fortunately, inevitably affects not only large-scale industrial production, but also the living life of people - in the plumbing store you can now buy a water heater and independently take care of comfortable conditions for yourself and your family.
According to the principle of operation distinguish:
They are convenient because:
The disadvantages include:
The main minus is that: