Neva heating equipment is one of the most popular among users. The technique of this brand adapted to Russian realities, works stably at reduced pressure in the line. But this does not mean that the operation is complete without breakdowns. Errors of the "Neva Lux" boiler will indicate malfunctions in the system, and their significance will help restore the operation of equipment.

Features of operation of boilers "Neva"

Gas boiler "Neva" is presented in wall and floor version... Single-circuit devices can heat an area of ​​180 m² and are characterized by low energy consumption. They operate on main and liquefied fuel. Since the combustion chamber is water cooled, connection to an external thermostat is possible. The organization of the chimney is carried out to the main shaft or to the turbo nozzle.

Double-circuit units are represented by the Neva Lux models. The design includes two heat exchangers for heating and hot water supply (DHW). For example, a bithermal radiator is built into the Neva Lux 7224 model. This is a tube in a tube, where water is simultaneously heated for two circuits.

Instrument control is mechanical and electronic. Special sensors monitor the operation of the boiler, in case of malfunctions, they send a signal to the control module. Then the display shows a fault code. To find out its meaning, you can look at the instructions.

Neva technique error codes

We will list the main malfunctions of the device, as well as indicate options for eliminating the problem.

Neva Lux bugs

Malfunction code What does How to repair
e1 / 04 The pressure in the heating system is reduced.
  • Bleed the air from the circuit, increase the pressure.
  • Diagnose the bypass valve. Switch work to heating the area, close the valve to the system. Water must go through the bypass line, otherwise the part is faulty.
  • Flush the pump from clogging, replace if faulty.
  • Repair of the pressure sensor circuit. Inspection of connectors, cables.
  • Check sensor stem for sticking. Switch off the instrument and remove the sensor and stem. If the diaphragm is damaged, install a serviceable element.
  • The flow sensor is out of order. Diagnose and replace.
  • Inspect the 3-way valve motor.
e2 Ignition error. What to do:
  • Unscrew the shut-off valve as far as it will go.
  • Change the bottle liquefied gas.

Inspect and replace if broken:

  • Spark plug and spark plug wiring.
  • Ionization wires. To do this, remove the wire from the candle - the work should be blocked, and 01 appears on the display. Reconnect the wire, hold down the K6 and Reset buttons.
  • Ignition transformer and its circuit.
  • Gas supply regulator.

Also remove dust from the spark plug by moving it closer to the burner (3 mm). Replace control board

e6 / 03 Problems with traction.
  • Clean out debris and soot from the chimney.
  • Examine the tubes leading to the pressure switch. If they are clogged, clean them of condensation or replace them with new ones.
  • Diagnose the pressure switch and its wiring.
  • Check the fan and its circuit.
e7 The water temperature is above normal. How to proceed:
  • Remove the blockage from the heating system.
  • Make sure the thermostat is working properly, check if it really shows the exact temperature.
  • Open the valve and bleed off excess air.
  • Clean the filter from dirt, debris, rust.
  • Check the location of the bypass.
  • The pump does not start. Carry out repairs.
  • Replace the fuel regulating part.
  • Connect switch S3 on the electronics module correctly.
01 Ignition fails. How to fix the problem:
  • Make sure that the shut-off valves are in good working order, open the gas cock.
  • The spark plug is out of order or clogged. Remove dust from the part. If the spark plug or its wiring is faulty, replace it.
  • Adjust the distance between the spark plug and the burner (3 mm).
  • When the electrode is turned on, a spark hits the combustion chamber. Isolate the breakdown site.
  • Measure the ionization current. Connect a microammeter to the ionization circuit, measure the readings. Normal should be between 3 and 5 microamperes.
  • Inspect the ignition transformer circuit. Repair.
  • Remove soot from the combustion block.
02 The equipment does not work due to overheating.
  • The heating circuit is clogged. Perform cleaning.
  • Install a working thermostat.
  • Bleed air using taps.
  • Clean out debris from the heating filter.
  • Bypass valve not installed correctly. Reconnect the part.
  • The pump is defective, which removes excess air. Run diagnostics.
  • Adjust the gas regulator.
05 The temperature sensor of the circuit is broken. Check the loop from the sensor to the electronic board. Connect a new element.
06 Domestic hot water temperature sensor problems.
07 The fuel regulator coil is out of order.
  • Measure the resistance of the coil with a multimeter. In operating mode, it should be 80 ohms.
  • The contacts between the coil and the electronic circuit are broken. Check the electrical circuit.
99 Electrical problem.
  • Grounding is not organized.
  • Breakdown on the boiler drum.
  • Flip the plug in the outlet

Other problems

Not all breakdowns are indicated by error codes. Some can be identified by signs.

The boiler does not turn on.

  • Check the availability of electricity if the boiler is connected to the mains.
  • The fuse on the electronic board does not work.
  • Circuit board closure due to leakage. Inspect all assemblies and parts for leaks.

The appliance pops on ignition.

  • Ignition power or pressure incorrectly set. Adjust the settings.
  • Clean the chimney, provide adequate ventilation in the room to maintain draft.
  • Clean soot and grime from burner assembly.

If you smell gas in the room, close the shut-off valve. Contact your gas service.

Weak water pressure when opening the mixer.

  • The line pressure has dropped. Wait for recovery or install the pump.
  • Remove dirt and limescale from water filter and parts of the heat exchanger.

The coolant temperature exceeds the set.

  • Dilute the hot stream with a cold stream, increase the circulation rate.

The standby mode is switched on, the panel does not function, the display shows "-".

  • The reason is the voltage drops in the network. As soon as it is restored, the equipment will resume work. It is recommended to install a stabilizer.

After reviewing the fault codes, you can proceed to eliminate them or contact service center... Good luck!

Codes of errors and malfunctions of boilers Neva Lux

The shutdown of the Neva Lux boiler, caused by a failure or malfunction of any of its systems, is accompanied by the corresponding error code flashing on the control panel display, which makes it easier to detect the malfunction.

Error codes, possible reasons and troubleshooting methods

Error 01- Problems related to unsuccessful ignition. The boiler is not working.

Gas supply faults - Open the shut-off valve on the gas pipeline, or check the pressure in the cylinder (LPG.)

Ignition plug defective - Replace spark plug.

Spark plug electrical circuit interrupted - Check electrical circuit and contacts.

Incorrect gap between spark plug and burner section - Set gap (5 + 0.5 mm).

The spark from the spark plug electrode jumps onto the combustion chamber shell - Bend the combustion chamber shell at the place where the spark plug is installed.

The spark plug is dirty - Wipe the spark plug from dust and degrease.

Ionisation plug defective - Replace plug.

Ionization plug electrical circuit interrupted - Check electrical circuit and contacts.

Incorrect gap between ionization plug and burner section - Set gap (3 + 0.5 mm).

Ignition transformer defective - Replace the Neva Lux boiler ignition transformer.

The electrical circuit of the ignition transformer is interrupted - Check the electrical circuit and contacts.

Burner block clogged - Clean burner block.

Gas regulator electrical circuits interrupted - Check electrical circuits and contacts.

Error 02- Overheating of water. The boiler is not working.

Clogged heating system - Clean the heating system.

Thermal relay defective (normally closed at temperatures up to 90 ° C) - Replace the thermal relay.

Filter in heating system clogged - Clean filter.

Defective or incorrectly installed, bypass valve - Check that the bypass valve parts are correctly installed and replace if necessary.

Defective pump or vent valve - Replace pump or vent valve.

Defective pump relay on the electronic board - Replace the electronic board.

Gas regulator not working - Replace gas regulator.

Gas regulator not adjusted - Adjust gas regulator.

Thermal relay (overheating sensor) electrical circuit broken - Check electrical circuit and contacts.

Error 03- Lack of traction. The Neva Lux boiler does not work.

Chimney or air duct blocked - Find out the cause of the blockage and remove it.

The tightness of the pressure switch tubes is broken - Replace the tubes.

Violation of the electrical circuit of the pressure switch - Check the electrical circuit and contacts.

The pressure switch is faulty (the contacts of the press switch must close at a pressure drop of 130 Pa) - Replace the pressure switch.

Condensation in the pressure switch tubes - Remove condensation from the pressure switch tubes.

Violation of the electric circuit of the fan - Check the electric circuit and contacts.

Fan defective - Replace fan.

Error 04 - Insufficient pressure water in heating circuit... The boiler is not working.

Reduced water pressure in the heating circuit - Bring the water pressure in the heating circuit to the recommended value.

Air lock in the heating system - Open the air bleed valve.

The water pressure sensor in the heating circuit is faulty - Replace the sensor.

Defective pump or vent valve - Replace pump or vent valve.

The electrical circuit between the pressure sensor and the electronic board is broken - Check the contacts of the connectors in the control unit and on the sensor and the sensor's electrical circuit.

Error 05- Failure of the heating circuit temperature sensor. The boiler is not working.

Heating circuit temperature sensor defective - Replace the heating circuit temperature sensor.

Electrical circuit "temperature sensor - electronic board" broken - Check the electrical circuit and contacts.

Error 06- Failure of the DHW temperature sensor. The Neva Lux boiler works only in heating mode.

DHW temperature sensor defective - Replace DHW temperature sensor.

The electrical circuit between the DHW temperature sensor and the electronic board is broken - Check the electrical circuit and contacts.

Error 07- Malfunction of the gas regulator modulator coil. The boiler is not working.

Broken gas regulator modulator coil - Replace the gas regulator (modulator coil resistance 80 Ohm).

Electrical circuit "modulator coil - electronic board" broken - Check the electrical circuit and contacts.

Malfunctions of boilers Neva Lux without an error code

Neva Lux boiler does not turn on

Lack of electricity - Contact the electricity service.

Fuse blown - Replace the fuse on the board.

Water ingress on the electronic board - Dry the board with warm air or leave it for two days in a dry place to completely evaporate the water.

Failure of the electronic board (RESET does not help) - De-energize and restart the boiler or replace the electronic board.

Pops in the burner

The minimum gas pressure and ignition power have been set incorrectly - Adjust the minimum gas pressure and ignition power.

Insufficient air supply - Clean the air intake pipe or duct.

The spark from the spark plug electrode jumps to the edge of the burner section or to the shell of the combustion chamber - Bend the spark plug or bend the shell of the combustion chamber, allowing the spark to slip into the area of ​​the holes in the nozzle of the burner section.

Dirty burner block - Clean burner block.

Gas smell

Gas leaks - Check the entire gas circuit for leaks, eliminate gas leaks.

Small exit hot water or lack thereof

Insufficient water pressure at the inlet to the hot water supply - Contact the housing and communal services service.

Water filter clogged - Clean the filter on the DHW line.

Heat exchanger clogged - Clean the heat exchanger.

The set temperature of hot water is not maintained (too high)

High inlet water temperature - Increase the flow of water through the DHW circuit or dilute the hot water with cold water, avoiding a decrease in the flow through the DHW circuit.

Small water flow through the DHW circuit - Increase the water flow through the DHW circuit.

Neva Lux boiler does not work in heating mode (but works in DHW mode)

Room thermostat jumper missing - Install the room thermostat jumper.

The room thermostat jumper connecting the contacts is faulty - Replace the room thermostat jumper.

Room thermostat defective (if a thermostat is installed) - Replace the room thermostat.

The temperature of the water entering the heating system is lower than the set

Heating circuit temperature sensor defective - Clean the temperature sensor from scale (if using an immersion temperature sensor), or replace the temperature sensor.

The boiler is in standby mode, the display shows the symbol "- -" and the boiler does not respond to pressing the control buttons

The supply voltage has gone beyond 190 ÷ 250 V - Restore the supply voltage within 190 ÷ 250 V. After 30 seconds, the boiler will automatically start in the mode in which it was before the voltage went beyond 190 ÷ 250 V.

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

_______________________________________________________________________________

__________________________________________________________________________

OPERATION AND REPAIR OF BOILERS

Gas wall boilers Buderus
Logamax models U042, U044, GB072, GB172. With open and closed chamber combustion. Repair and service methods, adjustment of operating parameters. Recommendations for maintenance.
Gas heating boilers Vaillant
Models: floor-standing Atmovit exclusiv, wall-mounted condensing Ecotec plus. Service, maintenance, settings of functional components. Hydraulic diagrams.
Gas wall boilers Ariston
Clas, Clas Evo, Genus models. Recommendations for repair, maintenance and service. Elimination of errors and malfunctions. Setting and adjustment methods.
Gas boilers Immergaz
Models Eolo Star, Eolo Mini, Nike Star, Nike Mini, Metos. Repairs and adjustments. Installation, assembly and connection. Operating mode settings and additional equipment.
Kentatsu Furst boilers
Wall models Nobby Smart. Condensing Smart Condens. Floor standing Sigma, Kobold. Solid fuel Elegant, Vulkan. Malfunctions and error codes. Description and characteristics.


Errors of the Neva Lux boiler and their meanings

Error 01 (E2)- Malfunction associated with unsuccessful ignition or overheating of the heating medium. The boiler is not functioning.

Code 01 for models Neva Lux 7023, 7224, 8224. Code E2 - Neva Lux 8023, 8029.

Burner clogged. Clean burner and nozzles. The ignition electrode is faulty, its electrical circuit is broken, the gap between the ignition electrode and the burner section is incorrect. Check the electrical circuit and contacts, set the correct gap (4-5 mm). Replace the ignition electrode. The ignition transformer is defective or its electrical circuit is broken. Check the electrical circuit and connector contacts in the control unit. Check and, if necessary, replace the ignition transformer. The ionization electrode is faulty, its electrical circuit is broken, the gap between the ionization electrode and the burner section is incorrect. Check the electrical circuit and contacts, set the correct gap (3-3.5 mm). Replace the ionisation electrode. Also, in case of error 01 (E2), the coolant overheating sensor in heating mode may be triggered. Find and eliminate the cause of the coolant overheating. The coolant overheating sensor is faulty or its electrical circuit is broken. Check the electrical circuit and contacts. Inspect the overheating sensor (must be closed at temperatures up to
95C). No flame due to gas valve failure. Check for contact in the valve connector and in the control unit. Replace the valve if necessary.

Error 02 (E7)- Overheating of the coolant

Code 02 for models 7023, 7224, 8224. Code E7 - models 8023, 8029.

The fan is damaged (the motor winding is burnt out, the bearing is jammed, the impeller is jammed, the fan's electrical supply circuit is broken). Check the continuity of the circuit and contacts in the connections. Ensure free rotation of the impeller. Replace fan if necessary. Also, in case of error 02 (E7), the coolant overheating sensor may be faulty or its electrical circuit may be broken. Check the electrical circuit and contacts. Check the overheating sensor (should be closed at temperatures up to 95C). The coolant overheating sensor has triggered in heating mode. Find out and eliminate the cause of the coolant overheating.

Error 03 (E6)- Malfunction in the combustion products removal system

Code 03 for models 7023, 7224, 8224. Code E6 - models 8023, 8029.

Clogged chimney or supply air duct. Clean the pipes. The supply pipes or the housing of the air pressure switch are damaged. Repair damage or replace tubing. The electrical circuit of the air pressure switch has broken. Air pressure switch defective. Check the continuity of the circuit and contacts in the connections. Replace the sensor.

Error 04 (E1)- Lack of water pressure or lack of circulation in the heating circuit. The device does not start.

Code 04 for models 7023, 7224, 8224. Code E1 - models 8023, 8029.

Small amount of water in heating system... Top up the heating agent in the heating circuit to the required pressure. There is air in the heating system. Remove air from the heating system. Clogged dirt filter in the heating circuit. Clean the filter. Bypass valve defective or incorrectly installed. Check and, if necessary, replace the valve. Failure of the circulation pump. Replace the pump. Even with error 04 (E1), there is insufficient mobility or souring of the stem of the flow sensor in the heating circuit, which transfers movement to the microswitch, rupture of the membrane of the flow sensor. Remove the microswitch from the flow sensor housing. By switching the boiler on and off again (turning on and off the pump), release the stationary stem; if this does not help to check the integrity of the membranes on the flow sensor. Microswitch defective or electrical circuit broken between microswitch and control unit.
Check the electrical circuit and contacts in the connector of the control unit. Replace microswitch. Failure of the servo motor of the three-way valve drive. Replace the servomotor. Gas supply interrupted. Check the presence and pressure of gas at the inlet to the gas unit. Click on the Reset button. Incorrect phase connection when connecting the unit to the mains. Make the correct connection of the phases.

Error 05 (E3)- Failure of the heating circuit temperature sensor. The appliance does not work in either heating or DHW mode.

Code 05 for models 7023, 7224, 8224. Code E3 - models 8023, 8029.

The temperature sensor of the heating circuit is defective. Replace temperature sensor. Violation of the electrical circuit temperature sensor - control unit. Check the electrical circuit and contacts.

Error 06 (E4)- Damaged DHW temperature sensor. The boiler will continue to operate in heating mode and in hot water supply mode.

Code 06 for models 7023, 7224, 8224. Code E4 - models 8023, 8029.

Temperature malfunction DHW sensor... Replace the DHW temperature sensor. Damage in the electrical circuit DHW temperature sensor - control unit. Check the electrical circuit and contacts.

Error E8- Communication error

The loop connecting the controller board with the control board is damaged, or there is no contact in the loop connectors. Check the integrity of the loop and the presence of contact in the connectors. Replace the ribbon cable if necessary. Control board malfunction. Replace the board. Faulty controller board. Replace the board.

Error E9- Supply voltage out of permissible limits

The boiler supply voltage is outside the range of 180 - 250 V. When the normal supply voltage is restored, the device will turn on automatically.

Troubleshooting

For 2 years I have been operating a Neva Lux gas boiler manufactured by Baltgaz. Now defects began to appear in his work. If you use it for a long time hot water, the pressure in the system drops and it stops by error 04. Although the pressure gauge shows the same pressure of 1.6 bar. Has to
constantly use make-up. How can I fix this?

Perhaps the pressure in your expansion tank is lower than it should be. It is then that error 04 is possible.

Six months ago, I installed a double-circuit boiler Neva Lux 8230. Recently I encountered such a problem. When hot water was required, I turned on the tap as usual. At first it went warm, and then cold again. Error 02 appeared on it at that moment. I tried to reset it with the "reset" key, but after that the heating turned on. After that, hot water was required again in the evening. I turned on the tap and everything worked fine. The device worked for 4 days without problems, but today the error appeared again. I studied it more carefully. It happens like this. After the transition to heating water for DHW occurs, a sound is heard inside, similar to air intake. At the same time, you can observe the instability of the manometer readings (approximately 0.5 in each direction). And all this is accompanied by the same strong sound not only from himself, but also from membrane tank(additional, external for 18 liters). After that, the pressure rises sharply to 5 bar. It turns off, the water temperature drops to 23C. And error 02 is displayed. The instructions say that I have air in the heating system, but I work with hot water supply. What's the connection? Maybe my 3-way valve is broken? Or is the filter in the heating system clogged?

Error 02 - the coolant is overheating. The fan may be broken or the sensor is damaged.

My boiler Neva Lux 7023 stops about 2 times a month by error 07. Restarting always solves this problem. And now a new error has appeared - E5. It works for a quarter of an hour and turns off. What happened to him?

Error E7 means that the coolant is too overheated. Perhaps your heat exchanger is covered with scale on the inside, and because of it there is poor circulation in the system. Did he start making some unusual noise with you? But regarding the E5, here you need to pay attention to the pressure switch or the fan. It is necessary to look at both that and that. In an amicable way, this problem should be solved by a specialist. Also, just in case, check if your chimney is icy.

The unit showed error 03. As I understand it, it means problems with the fan. When checking, I applied voltage to it - everything is normal. I also checked the pressure switch - it is also working properly. It turns out a relay on the board? A couple of years ago I came across a similar one. But then an acquaintance helped me out, giving from his old unit. Tell me, is it possible to work somehow without this relay? I tried to manually spin the fan, it started to work, but the gas did not come in. Is the same relay responsible for this? But now the error was 01.

In order for the relay to work longer, you need to set it up more carefully. gas valve and heating power, and it is advisable to install a room thermostat. All this not only increases the service life of the device, but also saves gas. To solve error 01, you need to check the voltage on the gas valve, whether it opens normally and whether gas is flowing. It is better to call a specialist, since all these checks are life-threatening. And the master has a diff. pressure gauge for assessing gas pressure. And so, most likely you have little house and you did not tune the system for the heated area. So a room thermostat is the best solution for you.

Help me please. In our new apartment, even before us, a wall-mounted double-circuit NevaLux 7218 was installed. During the day, it constantly stops by mistake 04. They began to feed, then the temperature began to drop. And now water has also flowed out of it (in the place where the heating pipe enters it). I had to turn it off. So you can't use it?

It is necessary to check the pressure switch. In the chimney, a small air exhaust pipe could be blocked.

My wall-mounted boiler Neva Lux 7023 (Baltgaz) has a problem with hot water supply. With heating, everything is normal, and as soon as I start parsing water, error E2 appears. This does not heat up the water. If the water is turned off, then it is perfectly normal to continue heating the apartment. The water pressure is consistently good. I looked in the instructions, it says that E2 is an error of unsuccessful ignition or overheating of the coolant. During DHW operation, the burner starts working and burns for 2 seconds. Then the thermometer shows a temperature of 95C, immediately turning off the device and an error. The water runs warm while the burner is on. What could have broken?

Try to check the DHW temperature sensor, perhaps this is the case. Although, in theory, the E2 error symbolizes problems with ignition, but then there would be no heating.

My wall-mounted Baltgaz boiler at first did not want to switch from heating system mode to hot water supply. Although, sometimes, for reasons I do not understand, it still worked as it should. First of all, I checked that all contacts were in good working order, then I checked the electric motor of the three-way valve. If you clamp it with a screwdriver, then the valve is in good order and works as it should. If you switch the mode (with the engine removed), then everything works. The movement of the stem is noticeable and consistent. I contacted the service center. The master who came to me suggested that the problem was in the flow sensor. He did not see the signal coming to him. We need a new one. But he did something to make the device work. It did not work for a day, and then I needed to turn it on. And it won't start. The indicator blinks, all possible symbols are highlighted. The reboot did not help. Disconnecting the power supply did not help either. What could be the problem?

Take out the connector on the board, and disconnect the wires one by one. First of all, those that are responsible for the drive of the three-way valve. Then reattach them. This should fix your problem.

I can't fix the boiler in any way Baltgaz neva... Error 03 constantly appears, the fan does not work during ignition. If you blow on the pressure switch tube, then it starts spinning. The device does not want to turn off on its own, you have to do it manually. How to be?

Find the hatch in the upper right corner. You need to open it and restart it.

Other malfunctions

Lack of spark for ignition.

Ignition plug defective or poorly installed. Correctly install the spark plug (the gap between the end of the spark plug and the burner section is 4-5 mm) or replace it. Loose contact between terminal and ignition wire. Check the contact of the terminal with the ignition wire. The ignition electrode is dirty. Wipe the electrode from dust and degrease.

The boiler does not turn on.

Lack of gas. Lack of water. Lack of electricity. Carry out appropriate checks (incoming gas, presence of water, connectors, fuses). Burner nozzles clogged. Clean the nozzles.
Air in the gas circuit. (May occur after prolonged inactivity). Turn on the unit several times until the error is eliminated. Fuse blown. Replace the fuse on the controller board. The temperature sensor of the heating circuit has been triggered. Check pump operation. If the pump is running, check the sensor. Defective gas valve. Repair or replace the valve. Deactivated boiler. Switch on the device again.

Pops in the burner.

Gas supply problems. Check the gas pressure upstream of the unit. Dirty burner. Check and clean the burner. Insufficient air supply. Clean the burner. Poor flame control. Check gas flow and gas pressure upstream of the burner.

Gas smell.

Gas leak. Check the entire gas circuit for leaks using soapy water or a gas detector.

Little or no hot water output.

Insufficient inlet water pressure. Increase pressure by installing an additional inlet pump. Clogged water filter. Remove and clean the filter on the DHW line. Heat exchanger with partially or completely blocked pipes. Clean the heat exchanger tubes.

Cold radiators in winter.

Set too low temperature heating or the temperature sensor is faulty. Install more high fever heating or replace the temperature sensor. The pump does not work due to contamination. Remove the screw at the front of the pump and turn the spindle.

Hot radiators in summer

Winter heating mode. Set summer mode.

___________________________________________________________________________________________

___________________________________________________________________________________________

Borino, ZhMZ, Siberia, Alpha Calor, Thermotechnik.
Adjustment gas automation Eurosit 630. Replacement of thermocouple and maintenance of the ignition burner.

What does error 01 mean, how to troubleshoot the repair of Neva Lux?

Double-circuit gas boilers Neva Lux 8624, 8230, 8224 are wall-mounted apparatus with forced circulation of the heat carrier (water or antifreeze). Repair and maintenance of Neva Lux boilers is carried out according to the service instructions by a specialized service organization, which is also engaged in installation, commissioning and service work with the delivery, replacement of faulty parts with new spare parts. heating equipment Neva Lux.

So, with error 01, the flame does not ignite in the combustion chamber or the ignition starts, but it turns out to be unsuccessful - the Neva boiler does not work. Concisely, in this case, one or several reasons for error 01 may be present at the same time. Consider all the causes of the emergency and give a full volume of recommendations for repair gas boiler Neva Lux when error 01 occurs. Technical information presented to service engineers of organizations for the repair of gas equipment.

Error 01 in the electronic control board is often found when repairing gas boilers from various manufacturers of electrical heating equipment with electronic control... The first common malfunction, the lack of ignition, is the incorrect operation of the entire chain of volatile and mechanical actions, starting from the pilot and ending with the main one. gas burner... Similar issues at the time of error 01 are related to wall-mounted boilers Visman Vitopend 100, Baksi, Kiturami, Electrolux, Ariston, Immergaz, Neva Lux 8224 and other models from various manufacturers. During an external examination of the gas appliance, it is necessary to make sure that all the manufacturer's recommendations for installing a gas boiler are followed: electricity, electronics, gas, chimney, air flow, correct installation of the Neva Lux boiler according to wiring diagram and the rules of the gas industry.

Repair of the gas boiler Neva Lux with error 01 information begins with checking the gas supply to the heating boiler fittings. Next, we check all RTs for operating condition, observing the contact ability of the relay. Gas modulator valve diagnostics, static and dynamic pressure... By default, the elements of ignition, ionization are subject to inspection and maintenance. In this case, the gaps with respect to the burner section along two electrodes must be observed. Eliminate distortions and mechanical damage interfering with the correct settings of the boiler. Diagnostics of the ignition transformer unit (coil), if there is no power to the ignition electrode.

During the repair of the Neva Lux boiler, which runs on liquefied gas, it is necessary to prepare documents for the last refueling of the gas tank (technical data of the fuel), a contract for those. maintenance of the gas boiler and call a service technician for diagnostics and repair of gas. apparatus.

Timely, constant maintenance of gas boilers Neva Lux gives uninterrupted operation of equipment, warmth and comfort in your homes. By carrying out scheduled repairs, the necessary replacement of spare parts, you extend the life of the Neva Lux boilers and make the right investment.

2017-05-17 Evgeny Fomenko

The device and principle of operation of boilers Neva Lux

Gas boilers Neva Lux are presented in two variations - wall-mounted and floor-standing, consider their device using some models as an example. Neva Lux 8618 is a single-circuit heating boiler, wall-mounted installation method, has a low level of energy consumption, a fairly high efficiency of 91%, a power of 18 kW. It can heat a room with an area of ​​30 to 180 square meters.

Works on both natural and liquefied gas. It has a small size, it is equipped with a combustion chamber that is cooled with water, it can also be connected to a room thermostat, which is convenient for use. Equipped with a protection device against overheating (boiling), a thermostat against overheating of the gas exhaust device. It can be connected to both the chimney and the turbo nozzle.

Neva Lux 8224 is a double-circuit gas boiler designed to heat a room up to 240 square meters2, as well as to heat water for household needs, with a throughput of 14 liters per minute. Its power is 24 kW, it is equipped with a closed combustion chamber.

The installation method is wall-mounted, equipped with a built-in 6-liter expansion tank, which makes it possible to connect the boiler to a 70-liter heating circuit. The design provides for two heat exchangers, a copper one for the heating circuit, and the second one, made of stainless steel, for hot water supply.

Powered by natural or liquefied gas, for ease of use it has a display that reflects the current and set temperature in the coolant.

Neva Lux 7224 is a wall-mounted, double-circuit device designed for heating a room with an area of ​​up to 240 m2, the throughput of water for domestic needs is 14 liters per minute. It can operate on natural gas and liquefied gas, the efficiency is 92%.

Boiler Neva Lux 7224

Equipped with a bithermal heat exchanger, thanks to which it is possible to reduce the final cost of heat. Equipped with electronic system self-diagnostics, and also a small display is installed on the case to indicate readings.

Neva deluxe 7023 - wall mounting, designed for heating a room up to 250 meters2, as well as heating technical water 13 liters per minute. It works not only from natural gas, but also from liquefied gas; for ease of operation, you can connect a room controller.

The smoke is removed forcibly, with the help of a built-in fan, air for burning the fire is forced from the street. Equipped with a closed combustion chamber, has a coaxial heat exchanger, expansion tank volume of 6 liters.

Neva Lux 8023 is a double-circuit wall-mounted boiler, which has the ability to provide heat to a room, the area of ​​which does not exceed 240 m2. The circulation of the liquid in the system is forced, with the help of a pump, equipped with a closed combustion chamber.

Fume extraction takes place thanks to an exhaust fan. The power of the device is 23 kW, the presence of two heat exchangers is provided, the heating circuit is of paramount importance, made of high-alloy stainless steel.

Major error codes

Like any other device, it periodically fails, then we will consider in detail the error codes for the Neva Lux gas boiler.

Gas boiler control panel Neva Lux

e1

Error e1. This malfunction indicates a low fluid pressure in the heating circuit.

The reasons may be as follows:


e2

Error e2. Failed ignition, check the following:


e6

Error e6. No cravings. Check the possible causes of this malfunction:


e7

Error e7. Exceeding the permissible temperature in the coolant.

What are the possible reasons and what to do, we will consider in more detail:


01

Error 01. Malfunctions caused by unsuccessful ignition.

Possible reasons:


02

Error 02. Indicates boiler overheating.

Possible reasons:


03

Error 03. In order to fix it, check:


04

Error 04. Low pressure in the heating circuit, you need to check:

  • Too much the pressure in the heating system has dropped, raise it to the recommended level.
  • Perhaps in the system an air lock has formed, remove the air using the vent valve.
  • Broken pressure sensor in the heating circuit. Replace it.
  • The pump is broken, clean it and replace if necessary. Visually inspect all connections and connectors on the control board.