Parapet boiler KSG / KSGV-P Luch with a closed combustion chamber, universal (right / left) connection to the heating system and the possibility of selection hot water for household needs (second circuit).
A feature of boilers of this type is a combustion chamber isolated from the room - air for the combustion process is supplied from the outside through a special coaxial chimney (pipe in pipe).
The boiler is equipped with modern gas automatics TGV307 (full analogue of the Italian EUROSIT630).
Ideal for installation in private houses and apartments.
Specifications | |||||
Model | KSG / KSGV-8 / P | KSG / KSGV-10 / P | KSG / KSGV-12 / P | KSG / KSGV-16 / P | KSG / KSGV-20 / P |
Thermal power, kW | 8 | 10 | 12 | 16 | 20 |
Heated area, m 2 | 80 | 100 | 120 | 160 | 200 |
Gas consumption, m 3 / h | 0,8 | 1 | 1,2 | 1,5 | 1,9 |
Efficiency,% | 92 | ||||
Working pressure, MPa | 0,19 | ||||
Inlet gas pressure, Pa | min-600 / max-2800 | ||||
Duct size, mm | 216x234 | ||||
Building wall thickness, mm | 270-455 | ||||
Dimensions, mm | 750x570x320 | 830x640x410 | |||
Weight, kg | 50 | 80 |
Detailed description
The parapet gas boiler KSG / KSGV "LUCH" is a modern heating equipment with compact dimensions and a closed combustion chamber. The air involved in the combustion process is supplied and removed through a single coaxial chimney. The air flows in such a chimney are divided: the external one works to supply fresh air, the internal one carries out the exhaust gases.
The small dimensions of the equipment make it possible to install it even in tight spaces with a small area. A gas boiler with a closed combustion chamber "LUCH" can be connected to communications from the left and from right side... The branch pipes for connecting gas, heating and water supply pipes are brought out both to the left and to the right side. Those nozzles that are not used are closed with plugs.
Insulated combustion chamber
A boiler with a closed combustion chamber is a gas heating equipment in which the gas burner device is located in a compartment isolated from the room. Thus, the air from the interior of the room is not used during the operation of the boiler. Special device coaxial chimney allows you to heat the incoming air, thus reducing heat loss.
Parapet gas boiler "LUCH" KSG / KSGV, thanks to a closed chamber and a coaxial type of chimney, can be installed on any wall. It does not require planning and organization of a traditional chimney, the terminal is displayed on any outer wall in compliance with the indents indicated in the passport from the window, land and neighboring buildings. It is not allowed to bring the chimney into the staircase, balcony or loggia. A boiler with a closed chamber does not require additional ventilation; it can be installed even in a small room (for example, in a kitchen).
Tubular heat exchanger
Reducing the size of the heating gas boiler LUCH did not affect its performance and economy. The efficiency of the parapet boiler is at least 92%. This was achieved, among other things, due to the special structure of the steel tubular heat exchanger... The heat exchanger is equipped with an optimal number of vertical tubes for the maximum possible heat removal. The heat exchanger itself is made of 2mm thick heat-resistant stainless steel. All these factors made it possible to significantly extend its service life.
Gas automation TGV307 (analogue EUROSIT630)
Reliable automation, time-tested - TGV307 (full analogue of the Italian EUROSIT630) controls the gas supply and is responsible for the safety of parapet gas boilers. Gas automatics TGV 307 are autonomous and do not need to be connected to the mains. Automation TVG307, depending on the readings of the coolant temperature sensor, modulates the flame of the main burner, thus regulating the power.
Automation ensures safe operation of gas heating equipment and produces an instant protective shutdown in the following cases:
The automatic gas burner device is located in the front of the parapet gas boiler (as in models with open chamber combustion). This simplifies its removal, maintenance and repair of heating equipment. The burner is a pipe-in-pipe type. Before being fed to the main outer tube of the larger diameter, the gas flows through the inner tube. In the inner tube, gas is preheated and treated with combustion. This approach can significantly reduce fuel consumption and increase efficiency.
Appointment of heating boilers KSG / KSGV "LUCH" parapet
Parapet boilers "LUCH" can help in solving the issue of heating and preparation of warm water. Models marked with KSG are equipped with one circuit and are intended for heating only. Equipment marked KSGV has two separate circuits - for heating and water treatment, so on their basis it is possible to organize a reliable heating and hot water supply system for domestic needs.
Single and double-circuit boilers with a closed combustion chamber "LUCH" are produced in the power range from 8-20 kW, which allows you to choose the optimal solution for rooms with an area of 80 to 200 m².
Floor-standing heating boilers of the KSG / KSGV "LUCH" series are modern, efficient and safe equipment that will allow organizing a reliable, non-volatile heating system in any premises with an area of 80 to 500 m². Gas boilers Russian production"LUCH", depending on the configuration, can operate on both natural and liquefied gas.
Floor standing gas boilers"LUCH" refers to equipment with an open combustion chamber, work in open and closed systems heating, maintain the natural circulation of the coolant, work in heating networks with forced circulation, do not require additional installation of smoke exhausters and fans.
Depending on the purpose in the series, there are:
The boilers of the TGA plant are equipped with one of the most reliable GGUs; in terms of reliability, the KSG / KSGV "LUCH" gas burner device surpasses its analogues. Before being fed to the burner, the gas passes through the automatic filter mesh. The filter retains particles of dust and debris, protecting the burner jets from clogging. The LUCH non-volatile gas boiler is equipped with a carpet-type low-flame burner - one of the most efficient. The number of jets in it is increased, while the diameter, on the contrary, is reduced. This makes it possible to reduce gas consumption and at the same time ensure uniform heating of the combustion chamber and heat exchanger, which increases the efficiency of operation and increases the reliability of the boilers at the TGA plant.
Russian-made gas heating boilers "LUCH" are equipped with non-volatile, reliable, modern automation. All automation elements use mechanical drives that are triggered when the pressure of gas, water, temperature, and the state of safety sensors change. The used automation has a built-in regulator, which makes it possible to smoothly and accurately modulate the fuel supply to the burner and instantly stop it when certain conditions... In addition, the regulator allows you to compensate for pressure drops in the main gas, which are not uncommon in real operating conditions.
Automation allows you to implement 5 steps of safety. The safety shutdown is triggered in the following cases:
Floor-standing boilers of the TGA plant are produced in a wide range of capacities. In the product line, you can find boilers from 8 to 50 kW, which allows you to choose the best option for heated areas of various sizes. Depending on the power, LUCH gas heating boilers are equipped with the following types of safety automatics:
In low power models, the thrust sensor is located on the front panel. Due to this, it was possible to reduce the length of the electrical circuit, and, consequently, the energy loss to overcome the resistance. The production of gas boilers is constantly being improved, changes are made to the design to improve efficiency, safety, ease of use and maintenance.
Russian boilers "LUCH" KSG / KSGV 8-50 operate on the principle of natural draft. Good, stable traction in any weather throughout the season was achieved thanks to a draft stabilizer and a bump stop in the design of gas heating equipment. The stabilizer with a bump stop is located in the upper part of the boiler above the heat exchanger.
In powerful models (25-50 kW), the flue is brought back. The flue pipe on the flue can be installed both upward and backward for ease of installation and compact placement of the boiler. If necessary, the cover with the tube can be easily removed and installed in the desired position. The diameter of the chimney corresponds to GOST and the capacity of the unit, which allows maintaining the efficiency of the equipment at high level and extend its service life.
Any of the boilers of the KSG / KSGV "LUCH" series can be converted from natural to liquefied gas and back. To do this, you just need to purchase a translation kit supplied separately. The procedure for transferring from liquefied gas to natural gas (and vice versa) is carried out with minimal interference in the design: the jets, the ignition tube are replaced and the automation is adjusted.
It must be remembered that any work on the installation, maintenance and conversion of gas boilers must be carried out only by certified specialists of the gas service.
Specifications:
Specifications | Boiler model | |||||
product name | KSG / KSGV-8 | KSG / KSGV-10 | KSG / KSGV-12 | KSG / KSGV-16 | KSG / KSGV-20 |
|
Rated heating capacity, kW | 8 | 10 | 12 | 16 | 20 | |
Rated input heat power, kW | 9,5 | 11,9 | 14,2 | 19,0 | 23,8 | |
Type of consumed gas | Natural gas, GOST 5542-87 Liquefied gas, GOST 20448-90 |
|||||
Natural gas pressure at the boiler inlet | Minimum, Pa | 600 | ||||
Nominal, Pa | 1274 | |||||
Maximum, Pa | 2800 | |||||
Nominal pressure of liquefied gas at the boiler inlet, Pa | 2940 | |||||
Average gas consumption, no more | Natural, m 3 / hour | 0.48 | 0.6 | 0.8 | 1.1 | 1.4 |
Liquefied, kg / hour | 0.35 | 0.44 | 0.525 | 0.7 | 0.88 | |
Efficiency,%, not less | 92 | |||||
Approximate heated area, m 2 | 80 | 100 | 120 | 160 | 200 | |
Maximum coolant temperature, ° С | 90 ± 5 | |||||
Maximum slave. pressure, MPa, not more | In the heating circuit | 0.19 | ||||
In the water heating circuit | 0.6 | |||||
Combustion products temperature at the outlet of the boiler, not less, ° С | 110 | |||||
Required chimney vacuum * | Minimum, Pa | 25 | ||||
Nominal, Pa | 4.0 | 4.0 | 4.0 | 4.0 | 5.0 | |
Maximum, Pa | 6.0 | 8.0 | 8.0 | 10.0 | 10.0 | |
Rated consumption of hot water, l / min, not less | Δ t = 25 ° С | 3.6 | 3.8 | 4.0 | 7.5 | 9.0 |
Δt = 35 ° С | 2.5 | 3.0 | 3.5 | 4.5 | 5.0 | |
Chimney connecting diameter, mm | 120 | 120 | 120 | 124 | 124 | |
Connecting dimensions of branch pipes | Strip | G 1/2 ″ | ||||
Cold / hot water | G 1/2 ″ | |||||
Heating | G 1 1/2 ″ | |||||
dimensions | height, mm | 615 | 675 | |||
width, mm | 340 | 400 | ||||
depth, mm | 448 | 510 | ||||
Weight, kg, no more | 35 | 48 | ||||
Error of readings of the temperature indicator, thermostat, ° С | +/- 5 | |||||
Climatic performance | UHL 4.2 | |||||
Warranty, years | 3 |
* Note 1: a vacuum of 10 Pa approximately corresponds to a chimney height of 6 meters.
Floor-standing gas boiler Hearth KSG - 7E Sit-630 - are characterized by ease of use, installation and provide maximum comfort to the consumer. Economical gas consumption and high efficiency are the main characteristics of these boilers. Wide the lineup represented by single-circuit and double-circuit boilers power from 7 kW to 25 kW. The boilers are equipped with EUROSIT automatics.
Features Outbreak KSG - 7E Sit-630:
Specifications | |
Brand name | Hearth |
Build country | Russia |
Boiler type | gas |
Number of contours | single-circuit |
The combustion chamber | open |
Type of fuel | Liquefied gas, Natural gas |
Installation | outdoor |
Heated area | 80 sq. m. |
Power | 7 kW |
Efficiency% | 85 |
Control | mechanical |
Country of origin | Russia |
Non-volatile | Yes |
Primary heat exchanger material | steel |
Liquefied gas consumption, kg / hour | 0.64 |
Natural gas consumption cub. m / hour | 0.87 |
Nominal pressure of natural gas, mbar | 13 |
Heat carrier temperature, ° С | 50 - 90 |
Max. water pressure in the heating circuit, bar | 1 |
Additional Information | gas control unit 630 EUROSIT |
Colour | White |
Model | SDG outbreak |
Connection and dimensions | |
Overall dimension | 360 × 655 × 480 mm |
Chimney diameter | 85 mm |
The weight | 37 kg |
Heating circuit connection | 2" |
Gas connection | 1/2" |
Consider a series of Premium AOGV and AKGV. This line has a power of 10 to 35 kW, and serves as a heating device for a residential building up to 300 square meters. The devices are characterized by high performance and reliability. The manufacturer provides for the operability of the equipment from natural or liquefied gas. In the case of a planned connection to a liquefied gas cylinder, it will be necessary to purchase an additional set of nozzles with subsequent adjustment of the equipment.
FLOOR GAS BOILERS AOGV PREMIUM | |||
Name | Heating area | Dimensions / Weight | Natural / liquefied gas consumption |
Heating Gas Water Heating Unit, one circuit and works only for heating. | |||
AOGV - 8 C / E | 80 m2 | 350 * 450 * 760/38 kg. | 0.81 / 0.63 m³ / hour |
AOGV - 8 11.6 C / E | 100 m2 | 350 450 850/57 kg. | 1.18 / 0.91 m³ / hour |
AOGV - 17.4 C / E | 160 m2 | 350 450 850/61 kg. | 1.76 / 1.36 m³ / hour |
AOGV-23.2 C / EM | 210 m2 | 430 565 850/66 kg. | 2.35 / 1.82 m³ / hour |
AOGV-29 S / EM | 260 m2 | 430 565 850/82 kg. | 2.95 / 2.28 m³ / hour |
AOGV-35 S / EM | 320 m2 | 430 565 850/96 kg. | 3.6 / 2.79 m³ / hour |
AOGV-45 C / EN | 400 m2 | 500 650 930/102 kg. | 4.6 / 3.54 m³ / hour |
Combined Gas Water Heating Unit, two circuits, one for heating the room, the other for heating hot water. | |||
AKGV - 11.6 C / E | 100 m2 | 350x450x850 / 57 kg. | 1.18 / 0.91 m³ / hour |
AKGV - 17.4 C / E | 160 m2 | 350 450 850/62 kg. | 1.76 / 1.36 m³ / hour |
AKGV - 23.2 С / ЕМ | 210 m2 | 430 565 850/68 kg. | 2.35 / 1.82 m³ / hour |
AKGV - 23.2 С / ЕМ | 210 m2 | 430 565 850/68 kg. | 2.35 / 1.82 m³ / hour |
AKGV - 29 С / ЕМ | 260 m2 | 430 565 850/86 kg. | 2.95 / 2.28 m³ / hour |
AKGV - 35 С | 320 m2 | 500 640 930/96 kg. | 3.6 / 2.77 m³ / hour |
Let's note the technical characteristics of the most popular models of gas boilers Ochag.
This volatile single-circuit unit is different affordable price... The approximate cost is 10,000 rubles. The material used for the manufacture is steel. Available in floor-standing design, the device is very simple and convenient to operate.
Gas boiler Hearth KSG-7 AT
This gas boiler Hearth uses fuel economically, the device is able to efficiently heat a room with an area of 80 m². Specifications:
The unit operates without interruptions and malfunctions even with minimal pipeline pressure. The package includes a gas block, built-in pressure and draft stabilizer, compact steel heat exchanger. The burner is made of high temperature resistant stainless steel. It is simple and convenient to maintain - the lining can be easily removed, gas is connected on both sides. There is a device that collects condensate.
Users note that this model has good characteristics... If you replace the burner nozzles, then liquefied gas can be used as fuel.
Outbreak KNG-24
The approximate price for such equipment is 25,000 rubles. It is double-circuit, in wall-mounted, small in size. Differs in stylish design.
In operation, the device is absolutely silent - you can mount it right in the room, it will not create discomfort.
On the front panel there is a liquid crystal display, which shows the current parameters. The boiler can be used for heating rooms that are equipped with a water heating system, as well as for heating water.
Technical indicators:
A floor heating system can be connected to such units. The combustion chamber is closed, it can operate on natural or liquefied gas. There are several stages of automatic protection. The weight of the boiler Hearth KNG 24 is 36 kg.
KSG-11 is a floor-standing gas boiler Hearth, designed for heating premises for various purposes.
Installation is simple and convenient, because gas can be connected from any side. The door can be mounted on any side convenient for the user.
There is a device for collecting condensate, the heat exchanger is made of steel, the thermal insulation is 30 mm. The type of combustion is low-flame; during operation, the device does not emit any noise.
Technical specifications:
Combined single-circuit boiler, maximum power is 16 kW. The device operates on gas and coal. Designed to supply heat to premises up to 160 m². Floor-standing installation, without auto-ignition and flame modulation. The efficiency is 75%.
The unit is floor-standing, with a heating capacity of 10 kW, and heats a room with an area of up to 100 m².
Gas boiler Hearth KSG-7 AT
Fuel consumption is 1.11 m³ / hour. The cost of the device is 11,000 rubles.
If you replace the burner nozzles, then liquefied gas can be used as fuel. The unit has a compact size, dimensions - 25x47x75 cm. Weight - 48 kg. Tank capacity - 18 liters.
Floor-standing single-circuit gas boiler Hearth KSG-7 E, which is characterized by stable operation at reduced pressure in the gas supply pipes. It is small in size, has an attractive design, is fuel efficient, and efficiently heats houses up to 80 m² in size. The weight of the device is 37 kg.
The combustion chamber is open, there is no auto-ignition, and there is also no flame modulation. This model is inexpensive, but its functionality is also very narrow.
Summarizing all of the above, it is worth noting that the Ochag gas boilers occupy a worthy place in the domestic market among the variety heating appliances... Wide range of models for technical specifications, appearance and the price allows each user to choose the most optimal option. Owner reviews of the Hearth boilers are mostly positive. Their efficiency and ease of use are noted.
You can also pay attention to German, Japanese, Korean, Czech and gas boilers.
Structurally, the Hearth boiler is made in such a way that it can be fitted into any heating system. The front door is reversible as required and opens either on the left or right side. Two return lines, from the side and from the back, make it possible to supply the heating medium from the convenient installation side.
In the lower part of the body, there is a combustion chamber; it is closed from the side and back with sections of the water jacket. A heat exchanger is located above the combustion chamber. High efficiency of heat transfer and heat exchange between the exhaust gases and the coolant is carried out due to the developed convective part of the heat exchanger, consisting of “flame” tubes.
In the upper part of the heat exchanger there is a smoke collector with a built-in draft stabilizer. In the front part of the smoke collector there is a draft sensor, in the upper part of the smoke collector there is an outlet pipe of the boiler. When installing the boiler in chimney, it is necessary to coordinate the diameter of the outlet pipe with the cross-section of the chimney. The technical parameters of the chimney must correspond to the technical parameters specified in the instruction manual.
In the middle part of the smoke collector, there is a partition plate, to ensure stable operation of the device, regardless of weather conditions... The heat exchanger, complete with the flue gas collector, provides effective work boiler without consumer intervention, and without requiring manual adjustments. Stabilizer draft contributes to the stable operation of the boiler in case of unstable draft.
A gas burner device of Russian production by Service Gas company is installed in the combustion chamber of the apparatus. It consists of a front panel, burner pipes, safety sensors (flame sensor and draft sensor), and a SABK AT control unit.
Below, under the burner tubes, there is an easily removable distribution grid. Designed to supply secondary combustion air
It is very important to ensure free air access through the lower part of the boiler along the distribution grid to the burner pipes when installing the boiler in the room.
The boiler must be installed with a clearance to the height of the foot relative to the floor. Boiler The hearth is connected to the gas mains on both the left and right sides. This allows the design of the block. A temperature sensor is installed on the front panel, which indicates the temperature in the room.
Buyers most often choose the following models of Ochag boilers:
Heat generators "Ochag" are marked with numbers and letters. The numbers indicate the power of the boiler, that is, the KST-20 M model has a capacity of 20 kilowatts. Letter designations are deciphered as follows:
The peculiarity of parapet heating boilers is that they do not need the installation of an expensive chimney. The smoke exhaust pipe is included with the heater. The device must be hung on the wall, after making a hole in it for the chimney pipe. Accordingly, installation of the heater is possible only on the wall that borders the street. The chimney is designed so that the wind does not blow into it.
Pay attention to the construction of the chimney. ...
There are two models in this line:
In one of our articles, we have already explained principle of operation double-circuit boiler ... The power of the units can be 10 and 12.5 kW. The boilers are equipped with automatic equipment SABK-AT, which is marked with the letters "AT", and Eurosit, which is marked with the letter "E". Combustion chamber of parapet boilers closed type, while in the design of the device there is not a single volatile element. The air for the flame enters through the smoke exhaust pipe from the street.
Due to the fact that the nominal cross-section of the nozzles for connecting to the heating circuit is 5 cm, the unit can operate in a gravitational system with natural circulation.
The boiler casing is insulated with mineral wool laminated with foil. In this case, the housing can be easily removed so that you can access the heater elements for cleaning. The heat exchanger is protected from scale and salt, so it does not need to be cleaned, which greatly simplifies the operation of the unit. The sensors for traction and the presence of a flame on the wick are responsible for safety. The igniter of the unit does not need adjustments; it does not emit soot during operation. The efficiency is 89%. 2.5 year warranty. How to clean the heat exchanger.
Double-circuit heating boilers The hearth of KSGV, and single-circuit heating boilers KSG are manufactured in the version of gas floor heating boilers.
These floor-standing boilers FOCUS KSG supplied with a highly efficient steel heat exchanger. For the most optimal removal of the gas combustion energy by the convective heating surface, the method of extensive high-speed heat removal with a smaller volume of the coolant in the boiler is used, thereby achieving a high efficiency.
A gas pressure stabilizer built into the gas block of a domestic boiler ensures uniform combustion gas-air mixture on main burners with a constant heating capacity, regardless of the gas pressure in the network.
The main gas-burners made of heat-resistant stainless steel with slotted grooves are placed evenly under the heat exchanger, creating a uniform thermal field in the furnace volume, which excludes the formation of local zones of overheating of the heat exchanger and its destruction.
You can send an application for boilers to email [email protected] and we will contact you shortly
Floor standing gas boilers Hearth | boiler KSG-7 | boiler KSG-10 | boiler KS (V) -12.5 | boiler KSG (V) -16 | boiler KSG-20 | boiler KSG-25 |
Rated power of boilers, kW | 12.5 | |||||
Approximate area of the heated room, sq. M with a ceiling height of 2.7 m | <70 | <100 | <125 | <160 | <200 | <250 |
Efficiency of boilers Hearth,% | 90,4 | |||||
Boiler gas flow rate, cubic meters m / hour | 0,87 | 1,11 | 1,46 | 1,78 | 2,4 | 2,8 |
Heating agent temperature control range, ° С, within | 50-90 |
|||||
Maximum temperature of the coolant at the outlet of the boiler, ° С, no more | ||||||
Working pressure of the heating agent in the heating system, MPa (kgf / sq. Cm.), No more | 0,1(1) |
|||||
Working pressure of water in a water heater, MPa (kgf / sq.cm), no more | — | — | 0,6 (6) | 0,6 (6) | — | — |
Hot water consumption through a water heater at a temperature difference of 35 ° C, l / h | — | — | 150 | 300 | — | — |
Overall dimensions of the boiler hearth: |
||||||
- width, mm; | 380 | 275 | 420 | 370 | 420 | 480 |
- depth, mm; | 460 | 500 | 530 | 530 | 570 | 570 |
- height, mm; | 655 | 750 | 670 | 820 | 850 | 850 |
Nominal pressure of natural gas, Pa | 1300 |
|||||
Boiler vacuum, Pa, within | 5-15 |
|||||
Maximum pressure of natural gas, Pa | 3000 |
|||||
Boiler weight, hearth, kg | 102 |
|||||
Connecting thread for heating agent inlet and outlet, inches | G2-B |
|||||
Connecting thread of a water heater, inches | — | — | G 1/2-B | G 1/2-B | — | — |
Connecting thread of gas inlet unions, inches | G 1/2-B |
|||||
- cross-sectional area, sq. Cm | 125 | 125 | 154 | 154 |
||
- boiler chimney height Hearth, m | ||||||
- diameter of the boiler chimney Hearth, mm | 100 | 100 | 125 | 125 | 140 | 140 |
Prices for gas boilers Ochag rubles | 12850 | 13200 | 14150 | 15000 | 18500 | — |
Send your request or application by email [email protected] and we will contact you shortly
In this class of hot water equipment, there is only one model with a power of 100 kW, which can be used to heat 1 thousand square meters of premises with a ceiling height of 2.7 m. Solid fuel boilers The hearth is marked with letters KP. The main type of fuel is wood with a moisture content of up to 30%, while wood trimmings and briquettes can be used as an energy source.
Solid fuel boilers The hearth is always white.
The firebox of the heater is large; it can hold 75 cm logs. On one full load, the device can work for up to 8 hours. The design of the heater includes a fan and a control unit that operate from the mains. You can set the required temperature of the coolant, which will be maintained due to the intensity of rotation of the fan. When placing firewood in the firebox, the fan turns off automatically.
Characteristics of the pyrolysis boiler Hearth:
The heater weighs 1.4 tons excluding the heat carrier. Floor-mounted. It requires an ordinary chimney with an internal section of 300 mm, since the diameter of the outlet pipe is 280 mm. The minimum height of the chimney is 5 m. To avoid the formation of condensation, the flue gas pipe must be insulated in areas that run in an unheated room and outdoors.
Universal heaters can operate on both solid fuels and natural gas. It can be heated with wood, briquettes and coal. This is convenient in areas where there are gas interruptions. Also, these units are installed when there is no central gas pipeline yet, but it should appear in the near future, and the house needs to be heated now.
There are two modifications in the line - these are KSTG and KSTGS. They differ in the type of installed automation and the color of the case. The KSTG line is produced with SABKT-ZS-RD and SABKT-ZD automatics, the body is completely white. KSTGS models are equipped with SABK-8-50S-RD and SABKT-8-50T automatics, white casing with red inserts. All universal heaters are independent of the mains supply.
In fact, the temperature of the battery in the apartment, according to the norms, depends on the weather. The main thing is that the degree of heating of the air corresponds to the standard.
It is written about what is the normal temperature in the apartment in winter.
General specifications:
In addition to automation, the KSTG and KSTGS models, with equal power, differ in the volume of the coolant in the boiler and the size of the furnace. For example, a 10 kW KSTG heater holds 34 liters of coolant, the volume of the furnace is 25 liters, and in KSTGS - 40 liters and 31 liters, respectively.
Installing solid fuel boilers is not the most difficult task. Basic system requirements:
Advice! The boiler should be connected to a chimney made of two pipes with heat-insulating material between them. This is to prevent condensation from forming. The height of the pipe is determined depending on the power of the model (this parameter is indicated in the instructions).
For the installation of boilers with an open firebox, it is recommended to equip a separate room. As a rule, it is located in the basement or in the basement. The boiler room should be equipped in accordance with the requirements of fire and sanitary safety.
When installing the boiler, the following rules must be observed:
Modern boilers operating on solid fuels have gone far from their "progenitors". Today, a boiler is a device that ensures long-term combustion of fuel by using the pyrolysis effect. Thanks to this, it was possible to significantly increase the efficiency of fuel technology.
In addition, modern boilers are equipped with a device for adjusting the heating power and combustion intensity. Thanks to this, the owners have the opportunity to choose the optimal temperature regime in the house, saving fuel.
The boiler is divided into two parts:
Fuel combustion takes place at extremely high temperatures, this process ensures the release of gas from the fossil fuel, as well as a large amount of heat.
Description
Heating household boilers cast iron KCHG are designed for heating residential buildings with a total area of up to 700 m2 with a ceiling height of 2.7 m. These heating boilers operate on low pressure natural gas in automatic mode according to the temperature of the coolant.
When using KCHG cast-iron gas boilers with a cast-iron heat exchanger in heating systems, the following is achieved:
Household cast-iron gas boilers KChG operate in automatic mode at a given temperature of the coolant in the heating system, have 5 degrees of protection in emergency situations:
These floor standing cast iron boilers use a high efficiency cast iron heat exchanger with a needle convection heating surface, the main burners are made of heat resistant stainless steel with slotted slots. The gas pressure stabilizer, built into the gas block, ensures uniform combustion of the gas-air mixture on the main burners with constant heat output, regardless of the gas pressure in the network, without requiring adjustment.
The traction interrupter (draft stabilizer) equalizes the air pressure in the suction zone into the ejector of the main burners and near the outlet of the gas-air mixture from the slot slots when the main burners are open, ensuring stable combustion of the gas-air mixture at a constant vacuum in the furnace without regulation, and blowing out the pilot burner during short-term rollover thrust.
The main burners are located evenly under the heat exchanger, creating a uniform thermal field in the furnace volume, which excludes the formation of local overheating zones of the heat exchanger and its destruction.
Advantages of KCG cast iron boilers:
When choosing, you should pay attention to the material from which the heat exchanger is made. Highlighted models that are made from:.
Become
This material has good ductility, the risk of cracking due to thermal stresses is minimal here. Usually steel heat exchangers are presented in inexpensive models. Its service life cannot boast of its duration, tk. is susceptible to corrosion.
Cast iron. This design weighs a lot and is more expensive than others. As a disadvantage, one can single out the fact that due to temperature drops such a heat exchanger can crack. However, its advantage is that it is not subject to corrosion and can successfully serve for 40-50 years.
Copper. This material is lightweight, corrosion resistant. Most often, copper heat exchangers can be found in wall-mounted models.
You can learn more about the types of heat exchangers for gas boilers
Before purchasing this or that model of heating equipment, you should think about whether you need hot water in addition to heating in the house. The design may be volatile or not dependent on the supply of electricity. Some installations have a chimney or do not have this unit.
The best gas boiler "Ochag" is one that is distinguished by its low noise, efficiency, convenience and ease of use, as well as safety. More popular today are two-circuit options. Wall-mounted ones have a smaller heating area, but are more compact. Before buying a gas boiler "Ochag", you must calculate its capacity. This parameter should be taken with a margin, because then the equipment will not work for wear and tear.
KSG "Pechkin"
Floor-standing gas boilers KSG "Pechkin" are designed to heat residential, administrative and utility premises with a total area of up to 500 sq. m. They have a simple design and simple intuitive control. Equipment characteristics and advantages:
Description of the model range
Gas heating boilers KSG "Pechkin" are represented by a large selection of models that differ in their power - it varies from 10 to 50 kW. Thanks to this, this equipment can heat houses and buildings of a large area. Some models from this model range are built according to a two-circuit scheme, so they can be used not only for heating rooms, but also for preparing hot water.
Floor heating boilers KSG "Pechkin" are designed to operate in closed heating systems. They are characterized by a simple and reliable design, as well as minimal maintenance requirements. A simple design means a minimum of parts, which significantly increases the degree of equipment reliability. The boilers are easy to install and do not require frequent maintenance. They can operate at a fairly low gas pressure, and are characterized by flawlessly stable performance.
Economy and environmental friendliness
The manufacturer of floor heating boilers KSG "Pechkin" managed to achieve reduced gas consumption, and the efficiency of the equipment presented reaches 88.5%. There is also a reduced amount of pollution emitted into the atmosphere. The coolant temperature in boilers varies from 40 to 90 degrees, and the maximum exhaust gas temperature does not exceed +110 degrees. Mains natural gas is used as fuel. The maximum pressure of the heating agent in the heating system should not exceed 0.1 MPa. Also noteworthy is the low noise level generated by the operation of this equipment.
Owners of gas boilers KSG "Pechkin" note the simplicity of control of the presented equipment and its reliability. The boilers do not require regular user intervention and are equipped with a minimum of control elements. They do not need to be connected to the electrical network for their work, so they can work in non-electrified utility buildings for various purposes. They will also become indispensable in suburban housing, where there is often a lack of electricity.
Other characteristics
The service life of boilers KSG "Pechkin" is up to 20 years, the warranty period is 2 years. They are easy to install and do not require any special skills for their installation. They are ready for use in heating systems immediately after connection. Built-in security systems from Italian manufacturers TGV or EUROSIT are responsible for the safety of others.
In order to buy a KSG floor heating boiler, you should familiarize yourself with the equipment presented in the catalog and choose a model that is suitable in terms of power.