Universal heating boilers Bosch. Unimat UT-L is designed to work on gas and light liquid fuel. The use of condensation technology allows the use of heat released during combustion as efficiently as possible, reducing the harmful effect on the environment. Block construction and other configuration features make their use optimal for large objects - industrial enterprises, hospitals, CHP, factory workshops.

Main advantages

  • Bosch Unimat UT-L boilers have traditional German quality, developed in accordance with the TRD 300 standards, are safe subject to installation and operation rules. Production in Russia provides absolute technical adaptation and the possibility of combining with the applied equipment during the arrangement or modernization of the heat supply system.
  • A wide range of power (650-19200 kW) and the ability to choose the execution of the heat exchanger allows you to perfectly adapt the boiler under the parameters of the room and climatic conditions. It is possible parallel or sequentially connecting to a single installation of several boilers with an appropriate increase in power.
  • Environmentally friendly at maximum heat transfer is achieved through the principle of the three-way passage of combustion products. Even with the use of liquid fuel, the emission of harmful substances is minimized.
  • Compact design and installed lightweight alloys simplify the transportation and installation of the boiler. At the request of the consumer, the front door and the burner can be hung on the right or left. Frame from a channel at the base of the boiler makes it possible to install without additional foundation (if there is a flat floor boiler room).
  • Modern engineering development optimize temperature loads on the body, increasing reliability and increasing the life of the equipment.
  • Characterized high efficiency due to the maximum decrease in probable thermal loss and the use of hidden heat flue gases. Condensation technology allows you to reach the efficiency above 100%.

Boilers Bosch Unimat UT-L combine excellent specifications With ease of service. The design involves the availability of the heat chamber and additional surfaces of heating, easy cleaning, the ability to inspect the rotary chamber. Additional comfort is provided by the individual selection of configuration.

For ease of operation, a consistent control system of heat supply control, boiler and burner, depending on user requirements and designs adapted to various software applications are used. The use of the SMS-930 functional module allows you to control the installation, which includes up to 8 boilers with a total or separate coordination of each of them.

Construction review

Boilers Bosch Unimat UT-L of various models are designed for burning natural gas or liquid fuel, respectively, the standard for the production of heat carrier low pressure. The versatility of the application is achieved by the possibility of setting design modules and optional equipment According to the needs of the user.

  • The covering of the boiler is made of structured (corrugated) aluminum sheet.
  • The boiler and the burner door are carefully insulated (layer of insulation 100 mm).
  • Connecting reverse feed lines, drain and safety valves are performed through fittings.
  • The flue gases collector is equipped with a control bottom hatch.
  • When water heating in the heating system, over 110 o C is triggered by an automatic safety limiter.
  • Supply of variatives: assembled with a burner and boiler or separately.
  • The heat exchanger can be built-in or separate.

The three-way passage in the heat exchangers provides uniform heating of surfaces and the maximum energy yield in combination with low emissions of harmful substances. Such a constructive solution guarantees a high coefficient of using boilers Bosch Unimat UT-L.

Table. dimensions Heat exchanger flue gases boilers Bosch Unimat UT-L

Type of heating boiler Unimat UT-L

Limit power, kW

Dimensions, mm.

Dry gas connection, mm

Reference frame, mm

H5 Schweller

UT38 / 6000 (LN) 4)

UT44 / 8000 (LN) 4)

UT48 / 10000 (LN) 4)

UT52 / 12000 (LN) 4)

UT56 / 14000 (LN) 4)

UT62 / 17500 (LN) 4)

1) The size L1 is approximate and depends on the manufacturer of the burner, design, as well as the actual thermal power. If the volume of the delivery includes heat exchanger of flue gases, the corresponding length should be taken into account according to the technical passport DA170 / DA171.

2) minimum transport sizes with dismantled fittings, burner and terminal box (without cable channel; with cable channel + 75 mm on the right).

3) Maximum height, taking into account the fittings of the boiler, lifting eyelet or stop ring of the door.

4) Unimatic is located on the side

Type of boiler Unimat. Power boiler Copper length Width of the boiler Height of the boiler Boiler weight without burner (kg)
(kW) (mm) (mm) (mm) 6 bar 10 bar
UT-L (LN) 2 750 2680 1324 2170 2200 2300
UT-L 4 1000 2680 1324 2185 2300 2400
UT-L (LN) 6 1000 2950 1424 2285 2800 2900
UT-L (LN) 8 1250 3220 1524 2385 3300 3400
UT-L 10 1350 2950 1424 2285 2900 3100
UT-L (LN) 12 1500 3675 1574 2570 4200 4500
UT-L 14 1900 3220 1524 2520 3500 3700
UT-L (Ln) 16 2000 3725 1674 2670 4700 5100
UT-L 18 2500 3675 1574 2670 4600 5000
UT-L (Ln) 20 2500 4075 1724 2820 5300 6100
UT-L (LN) 22 3000 4570 1824 2920 6900 7600
UT-L 24 3050 3725 1674 2770 5000 5400
UT-L (Ln) 26 3500 4700 1924 3020 7700 8600
UT-L 28 3700 4075 1724 2900 5700 6500
UT-L 30 4150 4570 1824 3000 7300 8000
UT-L 32 4250 5090 2124 3300 9300 10800
UT-L 34 5200 4700 1924 3085 8300 9200
UT-L (LN) 36 5250 5320 2274 3435 11400 13000
UT-L (LN) 38 6000 5520 2424 3585 13400 15700
UT-L 40 6500 5090 2124 3285 10200 11700
UT-L 42 7700 5320 2274 3435 12400 14100
UT-L (Ln) 44 8000 5980 2574 3735 16000 18600
UT-L 46 9300 5520 2424 3585 14800 16900
UT-L (LN) 48 10000 6315 2724 3885 19300 21900
UT-L 50 11200 5980 2574 3765 17800 19900
UT-L (Ln) 52 12000 7050 2924 4115 24700 27000
UT-L 54 12600 6315 2724 4025 20200 22800
UT-L (LN) 56 14000 7530 3224 4525 30800 34400
UT-L 58 14700 7050 2924 4225 25700 28100
UT-L 60 16400 7530 3224 4525 32300 35800
UT-L (LN) 62 17500 7980 3424 4725 36700 38800
UT-L 64 19200 7980 3424 4725 37800 39800

general description

The body of the boiler consists of a cylindrical body located in the center of the heat pipe, and in the circumference of the smoke-frame pipes of the second and third stroke.
The heat insulating layer is mineral wool Under aluminum protective trim.
Fully folded front door of the boiler opens into the right and left side.
All boiler seams are made automatic welding. All tests and complete equipment surveillance is made at the factory.

Possible equipment of the boiler:
1. Flange simple VL stream space with safety reinforcement (duct sensor, maximum and minimum pressure relay, pressure gauge, sleeve for temperature sensor);
2. Flange simple RL reverse stream (a sleeve for temperature sensor and nozzle for connecting the compensation pipeline);
3. The heat exchanger of the outgoing gases - the economizer (execution of the integrated module);
4. LBC boilers management system (provides boiler power control, maintaining and adjusting the temperature coolant temperature);
5. LSC boilers management system (cascading management in weather-dependent mode);
6. RT circulation device (mixing pump, electric valve, shock fittings);
7. Module maintaining a boiler in the "hot" reserve (pump, check valve, shock fittings and an electric valve);
8. WTM water treatment module (timer control or water quality).
Boilers can be equipped with Dreizler, Saacke, Weishaupt U Oilon.

The reliability of the three-way structures of UNIMAT boilers has been repeatedly proven by examples of their practical application in 140 countries of the world. The pipe-tube water boilers of the Unimat series are offered different sizes and can operate in a cascade.


UT-L boilers can be used in hospitals, private and apartment buildings, office institutions, as well as on industrial enterprises. Due to the high degree of versatility, UT-L can be used as a backup boiler or used to cover peak loads.

The water boiler may be offered as part of a fully equipped functional module, including a boiler body, a burner device, exhaust heat exchanger (economizer), as well as security and security management systems.

Basic equipment

Completeness of delivery depends on customer preferences

Boiler room components:

  • WTM water treatment module
  • ECO 1/7 Heat Exchanger
  • ECO 6 exhaust gas heat exchanger for use as a condensation heat exchanger
  • SP / RP feed / reverse link connecting pipes
  • RTS Reverse Flow Temperature Devices
  • GRM fuel supply module
  • OCM liquid fuel fuel supply module (fuel circulation module)
  • OSM liquid fuel fuel supply module (fuel supply module)
  • BCO boiler control cabinet
  • SCO Boiler Cascade Control Case

More information about

  • Effective three-way design
  • Effective thermal insulation, high efficiency
  • It is allowed to use low temperatures Reverse Flow (from 50 ° C)
  • The maximum allowable difference between the temperature of the reverse and direct flow of the boiler 50 to
  • Permissible minimum boiler load - 10% of nominal power
  • Well combined with burner devices of leading world manufacturers
  • Reducing emissions of harmful substances due to the use of modern burner devices and careful selection of the combination of boiler and burner
  • Easy maintenance due to the fully opened front door of the boiler
  • Lack of turbulizers in smokery pipes
  • Suitable for liquefied gas and light liquid fuel
  • Construction confirmed by long-term exploitation

The heat pipe ends with a rotary chamber of flue gases washed with water, which goes into the second course of smokehead pipes. Total boiler has three stroke heat exchange: the first - in the firebox of the boiler (radiant heat exchange), the second and third - in the smoke-step pipes of the boiler (convective). The arrangement of smokery pipes in a circle provides the optimal mode of flue gases. The smoke tubes do not have internal turbulizers creating additional resistance to the movement of combustion products. The furnace chamber, water space, radiant and convective heating surfaces are optimized and mutually agreed.

The front door of the boiler opens completely. Depending on the preferences of the customer, the loops can be located on the left or right. Thanks to the fully opened door of the boiler, it is possible to fulfill full maintenance, cleaning and revision. The absence of turbulizers in the pipes of the second and third turn reduces the complexity and time costs for regulatory work on maintenance boiler. High-quality mineral wool insulation surface minimizes losses by radiation. At the request of the customer, the boiler can be equipped with a built-in or separate economizer, as well as a condensation heat exchanger.

Range of capacity of hot-three-way fireboat-smoke boilers UNIMAT UT-L ranges from 750 to 19200 kW. Designed to work with gas, diesel and combined burners.
UT-L boilers are presented by 2500, 3050, 3700, 4200, 5200, 6500, 7700, 9300, 11200, 12,200, 14,200, 11200, 12,200, 14,700, 16400, 19200, 14,200, 16400, 19200 kW.

Application area

UT-L boilers are an ideal solution for heat supply systems, including city trunk networks. The UT-L model is used in hospitals, apartment buildings, office buildings, as well as various industrial enterprises. In addition, the UT-L boiler is ideal for use as a backup or peak boiler on thermal electric stations.

Reliable technology

The reliability of the three-way design of UNIMAT UT-L boilers is repeatedly proven by examples of their long-term use in 140 countries of the world. The water boiler has the marking of the CE, and its design and equipment correspond to the European directive for pressure vessels. The boiler is certified in accordance with the requirements of the technical regulations of the Customs Union and is intended for use in temperatures mode up to 110 ° C and pressure up to 16 bar.

High level of efficiency

High-quality mineral wool insulation surface minimizes losses by radiation. At the request of the customer, the boiler can be equipped with a built-in or separate economizer, as well as a condensation heat exchanger. Standard settlement efficiency without heat exchanger of exhaust gases is up to 95% and to 105% when using a condensation heat exchanger.
Low emissions of harmful substances due to application modern Systems Burning and optimal combination of boiler and burner. Well combined with burners of many manufacturers.

Installation and maintenance

Compact design to facilitate the delivery of the boiler to the object in case of limited space. Simple commissioning due to pre-parametric boiler management. Simplified installation of wiring at the installation site of the boiler due to connected connections. Easy service, cleaning and revision due to the fully opened front door of the boiler. Depending on the preferences of the customer, the loops can be located on the left or right. Dymaging pipes without turbulizers.

Simple and convenient control

Intelligent and regulation systems provide additional features For energy saving. Compact and affordable CONTROL 8000 system with an intuitive touch screen. Alternatively, for complex boiler systems, you can choose the BCO boiler control system.

File name Valuable to Download
Certificate of compliance RU_S-RU.ME09.B.00107_EN until 06/25/2022. Download (JPG 0.6 MB)
Certificate of conformity RU_S-RU.MO09.B.00089_EN until 03.04.2022. Download (PDF 0.4 MB)
Certificate of compliance RU_S-RU.MO09.B.00026_EN until 28.03.2021 Download (PDF 1.4 MB)
Product brochure Download (PDF 3.3 MB)
Declaration of conformity until 06/25/2022. Download (PDF 0.4 MB)
Certificate of conformity TC010. until 14.10.2023 Download (PDF 0.9 MB)
Certificate of Compliance TC016. until 14.10.2023 Download (PDF 0.9 MB)
Pattern of the questionnaire Download (PDF 0.2 MB)
User's manual Download (PDF 9.0 MB)
Specifications Download (PDF 0.2 MB)
Main dimensions Download (PDF 0.6 MB)

Equipment level

Water-heating boiler Unimat UT-L is offered as a fully functional unit included with the associated components. Equipment equipment can vary freely and configure in accordance with the requirements of the customer. The basic set of high-quality equipment includes a boiler housing, a burner, heat exchanger of exhaust gases or a condensation heat exchanger, as well as a control system and security devices connected to it and a compact system Control 8000.
Alternatively, you can also choose the BCO boiler management system along with the control cabinet. All wire connections have already been performed in the embedded terminal block. Pre-mounted marked cable harnesses simplify the electrical installation of the boiler control cabinet with a terminal box.

Equipment

  • System control Management 8000 (Alternatively: BCO boiler control system inside the control cabinet)
  • Direct stream nozzle complete with necessary devices
  • Safety valves
  • Reverse Flow Pipe Completed with Required
  • Eco Exhaust Gas Heat Exchanger
  • Torch device
  • Gas ramp
  • Support Rama
  • Isolation with trim
  • Shut-off drainage valve
  • Terminal box
  • Viewing hole
  • Injection device
  • Watching hole on the side of flue gases

Related components boiler rooms

  • WTM water softening module
  • ECO 1/7 Heat Exchanger
  • ECO 6 Condensation Heat Exchanger Heat Exchanger
  • SP / RP direct / reverse flux
  • RTS Reverse Flow Temperature Device
  • Module with GRM gas regulator
  • OCM liquid fuel circulation module
  • OSM liquid fuel supply module
  • SCO control system
UT-L. UT-L. UT-L.
Size of the boiler 18 24 28
2500 3050 3700
2734 3350 4020
Transport weight, kg 4460 4880 5940
Boiler length, mm 3675 3725 4075
Boiler width (general), mm 1574 1674 1724
Boiler width, mm - - -
- - -
Total height, mm 1930 2030 2080

Industrial heating water heating boilers Unimat UT-L UT-L. UT-L. UT-L.
Size of the boiler 30 34 40
Nominal heat production, kW 4200 5200 6500
4578 5675 7147
Transport weight, kg 7530 8480 10500
Boiler length, mm 4570 4700 5090
Boiler width (general), mm 1824 1924 2124
Boiler width, mm - - -
Distribution area of \u200b\u200bthe burner door, mm - - -
Total height, mm 2180 2280 2480

Industrial heating water heating boilers Unimat UT-L UT-L. UT-L. UT-L.
Size of the boiler 42 46 50
Nominal heat production, kW 7700 9300 11200
8403 10118 12190
Transport weight, kg 12830 14630 18770
Boiler length, mm 5320 5520 5980
Boiler width (general), mm 2274 2424 2574
Boiler width, mm - - -
Distribution area of \u200b\u200bthe burner door, mm - - -
Total height, mm 2630 2790 2940

Industrial heating water heating boilers Unimat UT-L UT-L. UT-L. UT-L.
Size of the boiler 54 58 60/64
Nominal heat production, kW 12600 14700 16400/19200
13635 16000 17620/20758
Transport weight, kg 21100 25970 33390/38690
Boiler length, mm 6315 7050 7530/7980
Boiler width (general), mm 2724 2924 3224/3424
Boiler width, mm - - -
Distribution area of \u200b\u200bthe burner door, mm - - -
Total height, mm 3090 3300 3600/3800

The reliability of the three-way structures of UNIMAT boilers has been repeatedly proven by examples of their practical application in 140 countries of the world. The pipe-tube water boilers of the Unimat series are offered different sizes and can operate in a cascade.


UT-L boilers can be used in hospitals, private and apartment buildings, office institutions, as well as industrial enterprises. Due to the high degree of versatility, UT-L can be used as a backup boiler or used to cover peak loads.


Design:

The heat pipe ends with a rotary chamber of flue gases washed with water, which goes into the second course of smokehead pipes. Total boiler has three stroke heat exchange: the first - in the firebox of the boiler (radiant heat exchange), the second and third - in the smoke-step pipes of the boiler (convective). The arrangement of smokery pipes in a circle provides the optimal mode of flue gases. The smoke tubes do not have internal turbulizers creating additional resistance to the movement of combustion products. The furnace chamber, water space, radiant and convective heating surfaces are optimized and mutually agreed.

The front door of the boiler opens completely. Depending on the preferences of the customer, the loops can be located on the left or right. Thanks to the fully opened door of the boiler, it is possible to fulfill full maintenance, cleaning and revision. The absence of turbulizers in the second and third turning pipes reduces the complexity and temporary costs of regulatory work on the maintenance of the boiler. High-quality mineral wool insulation surface minimizes losses by radiation. At the request of the customer, the boiler can be equipped with a built-in or separate economizer, as well as a condensation heat exchanger.

Equipment:

The water boiler may be offered as part of a fully equipped functional module, including a boiler body, a burner device, exhaust heat exchanger (economizer), as well as security and security management systems.

Basic equipment


Completeness of delivery depends on customer preferences

Boiler room components:

  • WTM water treatment module
  • ECO 1/7 Heat Exchanger
  • ECO 6 exhaust gas heat exchanger for use as a condensation heat exchanger
  • SP / RP feed / reverse link connecting pipes
  • RTS Reverse Flow Temperature Devices
  • GRM fuel supply module
  • OCM liquid fuel fuel supply module (fuel circulation module)
  • OSM liquid fuel fuel supply module (fuel supply module)
  • BCO boiler control cabinet
  • SCO Boiler Cascade Control Case