House, design, repair, decor. Yard and garden. Do it yourself

House, design, repair, decor. Yard and garden. Do it yourself

» The first launch of the Ariston gas boiler. Work modes and settings of Ariston boilers

The first launch of the Ariston gas boiler. Work modes and settings of Ariston boilers

Some boiler malfunctions may be due to the wrong parameters in the settings of the service menu. This may occur for example after unqualified interference or ... as one day it was in my practice, after pouring the boiler board with water.

Of course, first of all, the service menu is used to configure, adjust and diagnose the boiler operation. In this article, I will share how to enter the Ariston Class 24 FF service menu and how to change the parameters, as well as bring values \u200b\u200bthat were installed in my boiler from the factory.

Before proceeding with any settings, it is important to carefully consider the menu structure, as well as understand whether it is necessary to interfere and change any parameters. Incorrect intervention can lead to serious malfunctions. For example, there is a parameter that is exhibited depending on the boiler version and is used by specialists when replacing the board.

Considering the foregoing, you must understand that some parameters given by me as "factory settings" may differ from the necessary specifically to you, and therefore all these television management and settings you carry out at your own risk.

Fast navigation on the article

Structure Menu Boiler Ariston

At first it may seem difficult, but how to figure it out everything will be simple and understandable, so:

Each parameter is denoted by a three-digit digital code. For example 228 (this is just a parameter code that depends on the boiler version)

The first digit of the three-digit code means a separate menu group, in the boiler there are six separate menu groups, each is responsible for its settings section. Here they are.

2 - Boiler settings

3 - Solar collector and cumulative boiler

4 - zone parameters 1

5 - Zone parameters 2

7 - Testing and maintenance

8 - technical parameters.

The second digit of the three-digit code is denoted by the submenu, and the third is the parameter itself to which access opens.

For example, the code 228 already known to us is decrypted as follows: 2 - Boiler settings (this menu), 2- Basic installation of boiler (submenu), 8 - boiler version (parameter).

So typing three-digit code 228 We access the set value of this parameter, which according to the table may vary from 0 to 5 and depends on the boiler version.

Tables with menu codes and a description of what is regulated by a specific code I will give a little lower, but for now let's figure out how to enter the boiler's service menu.

Cottage service menu

For all manipulations with switching modes, only 4 buttons are involved - plus, minus, OK / MENU, ESC.

It is important to understand that not all the boiler menu items will be available to you, some of them will be available only when connected to the boiler additional devices, eg external sensors or solar collector.

And most menu items are available only on the service code, I will tell you about it below, but for now, "practice on cats"

Our cats will be open to free access values. But first, read how to work with the menu.

How to work with menu

Pressing the "OK" button on the digital indicator flashes the number 2 - it will be the first digit of the future three-digit code (menu number)

Buttons "Plus" and "minus" can be changed this value from the group number 2 to any other group. To fix the selected group for further introduction of the code number, you need to once again click "OK" - after that it begins to flash the second digit of the future three-digit code (submenu)

Selecting the submenu fix it with another pressing the "OK" button and choose and fix the third digit (parameter)

Everything! Now the screen will not display the three-digit code, but the established value of this parameter that can be changed by pressing the plus "minus". Making the necessary changes do not forget them to fix by clicking "OK".

Note that selecting the desired menu, after a few seconds inactivity, the one-step appearance of the three-digit code will begin (for reminding where you are) and the parameter corresponding to this menu.

The ESC button serves to output and menu of settings and return to the previous step. The output is made step by step, one press is equal to one step back.

Practitioner

Now, if you want to practice, it would be better to understand the switching order. For example, enter the menu code 701 by this, you turn on the forced air removal mode, in fact use the pump in the boiler for 6 minutes.

When this mode is turned on, the "P I -" symbol will be shone to exit the "Anti-duch" mode without waiting for 6 minutes if you press ESC.

Then, with the ESC, try to go back and go to 300 mode, which means (the installed water temperature in the boiler) in the values \u200b\u200byou can see the temperature that is currently set by the GVS regulator.

How to enter the closed menu sections on the access code

So, if you understand how to work in the menu, it's time to move to more serious things. The overwhelming majority of all settings are closed from accidental intervention by the access code. Therefore, to proceed with the settings of the boiler, make the following actions.

Click "OK" several times, as long as the indicator does not value 222 - then hold the "plus" until the value becomes 234 - then again "OK" - everything is ready!

Now we constantly have one digit 2 and one more 2 blinks -Who, as you understand it means the following - enabled Menu 2 and you can select a submenu, and then the parameter. By setting the desired three-digit code and pressing "OK" we will see the value of the parameter that can be changed.

Use the ESC button to go back and go to the selection to other discharge menus and the submenu.

Tables with three-digit codes, descriptions and set values

Values \u200b\u200bare read in white fields, these are values \u200b\u200bused in my boiler. If there is no correction, it means that I have the same meanings as the table printed. To enlarge, click on the photo of the table.




Table 3.

Turning the Ariston BS 24 FF boiler to heating mode, set the temperature of the coolant more than 60 degrees and the beginning began to occur - after the burner is turned off, after 5 seconds, cracklers are beginning in the boiler, approximately at the top in the heat exchanger area. What is this fault? In the operation of the boiler 2 years.
Maintenance was carried out besides cleaning the heat exchanger from the inside of scale and other things! The master who conducted maintenance said that there is no need to clean from scale! The device as he worked 2 years ago, so works unchanged, except for cracking after the burner extinction, but only at the coolant temperatures above 60 gr.
Conducted installation and installation of the wall-mounted boiler Ariston. Heating works fine. The DHW turns on, heats about a minute and turns off the flame, the green 40-80 are burning, then blinking the green 40-50 error and the yellow chimney "alert for insufficient water under pressure." After that, the flame appears and heats on, then it turns off again.
Copper Ariston UNO is set on the summer mode. Turn on in Crane hot waterThe boiler works fine (warms the water). After turning off the hot water, gas is lit on the contour of radiators, and the boiler continues to warm the water in the system. After some time, he stops or stops (it seems to be "recalls", that it is on the summer mode) or to make attempts to light gas on the heating system again. But he does not work.
Most likely, you have to reflash the software memory.
Installed ARISTON UNO 24 MI gas boiler. At first it worked fine, but the problems began 3 months ago, first with hot water, and then with heating. When the boiler is ignited, the ignition clicks are heard for 7-10 seconds, and then the protection is triggered, the boiler swings, a red light is on. After pressing the reboot button ignites and works normally. It used to be 1-2 times a day and only when the hot water is turned on, and now constantly. Tell me what could be the problem?
Clean the zero flame control electrode, for sure the soot covered. We do not know who is responsible for control - clean everything in the combustion chamber over the burner does not hurt. Well, if it does not help, then the board.
What is the reason for blocking the ARISTON UNO 24 MFFI boiler when the heating is turned on? Moreover, the blocking occurs, approximately after half an hour - when the batteries are warmed completely. I thought there was a temperature sensor, but the indicator "says" the ignition.
It is necessary to repair a fee, not necessarily change.
Faulty boiler Ariston UNO 24 MFFI EE - turns off and burns yellow lamp. How to fix?
Check the working capacity of the turbine.
Check the presostate.
Check the performance of email. fees.
The boiler Ariston UNO 24 operates in heating mode and periodically off. With the swelling of all diodes. At incl. Its on the button on. It begins, for some time it can work for an hour or half an hour and off. It seems to me that fee.
Recently, repair spent. Made the following.
1- Clean the airlock valve. Completely did not work.
From this in the heat exchanger due to the presence of air, it turned into some black flakes. (Local overheating affected).
2- washed both heat exchanger. The secondary was scored by 90 percent.
The second operation did twice. But I think it will have to repeat in the spring.
3-washed filter on the return.
It seems that the secondary heat exchanger is scored, overheats and turns off. Need to rinse!
In operation Gas boiler EGIS Plus 24 FF. Pressure in the heating circuit for two weeks by 0.5 atm. Checked the expansion tank, there was zero. Pumped to 1ATM. Now it began to fall slower, in the expansion tank the pressure is normal. For what reason can there be such a drop in pressure in the Republic of Belarus? Externally, it is whole, the air does not poke. Mostly the pressure in the heating circuit drops after using hot water. For
pumping closed cranes for feeding and reverse. I merged the water from the boiler, it turned out a little when he pumped out. Until this season worked fine.
If we are confident that in the circuit of the heating system drops, it means that you look for leakage in it.
Installed and connected Ariston Egis plus 24 with open camera combustion.
There is a problem, you need advice:
1. The temperature in the DHW circuit does not depend on the set parameters and always maximum. In the heating circuit is adjustable.
2. The feeling that the boiler does not change the intensity of the flame (in both modes). It is lit at the maximum and works so before turning off the maximum temperature. Somehow configured or something more serious?
First you need to watch the gas valve settings.
The boiler in the work of heating gives an error 104. Pressure in the expansion tank is 1bar. The pressure in the device 1.4bar does not fall, the bypass is fine, the turbine and everything else is also normal. Everything is purely by contour. What can the third digit in the error? Copper ariston class chimney. And if we have a pressure sensor? I did not find it.
If an error only when working on heating, most likely, a malfunction must be sought in the heating system, I would begin with checking filters with CO. Most often no, but there were instances with a pressure sensor. For loyalty, check the menu parameter 247 and, if necessary, set 0.
Made the installation and launched the ARISTON CLAS SYSTEM 15 FF wall boiler. When working it gives an error 104. Pressure in the expansion tank 1. Pressure in the 1.5 boiler does not fall. Filter clean. Air in CO NO. The heat exchanger is washed clean. What could be for a malfunction? On a day, 3-4 times stops. I noticed that when an error occurs, some hissing and a pressure jump from 1.5 to 1 and again at 1.5 it becomes and an error 104 becomes.
Options: Board, pump, NTC.
Tell me, the heat carrier must necessarily drain before loading the air?
We merge the coolant until the pressure gauge shows 0. Before you overlapping the cranes under the boiler. Then download the pump pressure in the air expansion tankBy checking the pressure by a third-party pressure gauge. Pump 1.0-1.2 bar. Open taps. Then pumped with pressure in Co, control the pressure to the boiler pressure gauge. Publish or through the fuel faucet or third
pump at the point of filling CO. Pump up to 1.3 -1.5 bar. We check whether the air vent is opened. Turn on the boiler, and if there is a mode for removing air from CO, then we chase the device in this mode. Also warming up to maximum. The air is removed from CO. We pass by heating devices And through the crane of Maevsky we blend the air of them. Pressure slightly falls. Sign up to the specified values \u200b\u200babove. Everything. If everything is correct, then when
heating to maximum temperature, pressure in closed system Does not rise more than 0, 3 bar.
Malfunction in work double-circuit boiler Ariston Egis 24 FF - when turning on hot water 20 seconds of work, the flame shocks and the error 109 failed the test of the troubliness. What is it and how to fix it? First, the burner rushes, and then the 109 DHW temperature lights up is the water temperature in the faucet? Is it possible to make repairs yourself?
Select one of the options:
1. Error 109 lights up and then the burner flops;
2. The burner sweeps and after that the error 109 lights up;
Place the temperature of DHS 50 degrees or less and see if there will be changes.
Tell me where is located on the gas boiler EGIS 24FF expansion tank, and a particular spool for pumping? And how to drain the water from the boiler? What to properly pump pressure into the expansion tank.
It is behind, from above behind the boiler.
- Close the entrance crane cold water in the apparatus.
- Open the hot water faucet on the mixer at any point of water treatment.
- Open the fuel faucet.
- Wait until the pressure gauge arrow will not sit on zero.
The problem is in the operation of the two-circuit boiler Ariston BS II 24 CF. When the heating is turned on, the burner starts and turns off after a short time, the system does not heat up completely, and the device is already turned off. Called the master, he said that the pump was faced, although when the boiler is turned on, a small vibration is felt and the feed pipe is heated and the first three radiator too (the remaining three there was no possibility to check). But
the reverse is a warm. The bug boiler does not give out. Tell me how to check the performance of the pump?
Turn off the boiler with a button and outlet; To block all the cranes, drain the water from the machine through the drain fitting, to close the board from above, so that the water does not hit, remove the pump and try to rotate manually - how easy it is.
1. The filter is scored on the return.
2 clogs the filter in the boiler (the tube where the pressure gauge comes).
3 scored heat exchanger.
4. The pump does not enter the operating parameters.
In the work of the egis boiler plus 24 FF. When I turn on the DHW, the device is turned off after 30 seconds and gives an error 303. Tell me, what could be damage?
Most likely, you will need to change the fee.
An ariston BS 24 FF boiler has been installed, 4 years worked without breakdowns. Now there is a problem: you specify the temperature, for example, 70, the boiler does not warm up the entire system, although it was before everything. Only the first 3 batteries are heated, respectively cools, the device is turned on for a while (the sensor on the dial shows a maximum of 40) and the heating turns off, although the return is a slight warm. I do not know what is the problem, can you need to put an additional pump? (Stabilizer is worth, filter only from mechanical impurities.).
Craised filter in the boiler.
We are going to connect a single-mounted wall gas boiler Ariston by 15 kW. Does the expansion tank need it? How to check the boiler after launch?
This model already has a regular expansion tank, but its volume does not always have enough to work. It is necessary to inspect the heating system. If it is large enough, you will need to cut the extra tank outside the boiler. Before starting commissioning, you should fill the heating system with water, including warm floors and radiators, as well as ensure the readiness of the chimney.
In the operation of the ARISTON boiler, which works from a cylinder with liquefied gas. Last time it became scary to include it: the volume of flame takes off high upwards. How can I fix and repair?
You need to see why there is no control of the flame, and that it failed - a gearbox or a flame controller, or there is a different reason for such a phenomenon.
Malfunction of the boiler Class Evo. Suddenly stopped turning on, only the fan works without stopping. Highlights errors 201 and 607. Is it possible to fix it?
Error 201 means closing or breaking in a hot water circuit temperature sensor circuit. Error 607 - Pressure Relay Contacts are closed before the fan is turned on.
In EGIS Plus 24, the heating modes were disconnected, only hot water was left. It became impossible to run: writes "fear of the board". How to repair yourself?
Measure the potential between the zero and the earth, there should be nothing. If there is a voltage at least 2-3 V, the boiler will write a mistake and you need to remove the potential. Then you should find out the voltage on the network: at 180-190, the fee will also be. If everything is in order, then problems in the board itself.
ARISTON GENUS 24 is connected, it began to issue an error "Out of the flame". How is it eliminated?
In the boiler is clearly too high gas pressure. Gas valve should be adjusted. It is also possible to have a problem with the air supply to the boiler.
The Class 24 two-round boiler stopped giving hot water, the error 103 is displayed. What can I do yourself?
This error code indicates the insufficient circulation of the coolant. It should be checked the water pressure in the DHW circuit if it is low, then it is possible to leak. If the feed does not give anything, or gives a short-term effect, you should call a specialist.
When you open the hot water crane, the wall gas double-circuit boiler Ariston Class 24 turns on, the d38 is displayed on the scoreboard, and after 2-3 seconds. 5p3 appears and immediately again D38, after 2-3 seconds again 5p3 and immediately again D38. And so on the scoreboard information changes during the first 20-25 seconds. Water heating. Next, the water is heated without problems and D38 is constantly on the screen. It started after it was stopped to dump the house, that is, the boiler
it works only on water heating. This is the first question. And the second: After closing the hot water crane, an error 104 lights up. The boiler starts only after pressing Reset. What could be the reason for these problems?
There was the same malfunction. We decided washing the secondary heat exchanger of the DHW. But rinse comes from every six months. The symptoms were one in one. Yet. There is a special device for washing, connects to the input / output of the DHW circuit. If they enjoy every six months, then enough such washing. If the heat exchanger is polluted by very deposits, then it is necessary to remove the heat exchanger, and "soak" in a solution with citric acid (vinegar).
Made the installation and launch of the Clas EVO 24 FF boiler. There was a malfunction. The boiler does not pump the heating system, the first two radiator are heated. Heating polypropylene. In this case, no errors give out. What could be the problem? I also want to add that the temperature quickly is gaining about one and a half minutes and the boiler goes out.
There is no circulation of the heating system, there may be a blockage or removed traffic jams with radiators, may be air both in the pump and in the system.
ARISTON CLAS SYSTEM 24 FF gas boiler was commissioned. When starting the boiler does not always be burned down, it can be seen that there is a spark, there is some amount of gas (I noticed the indications of the counter), but the flame does not ignite. After 8 seconds, as it should be, an error 501 is displayed. Sometimes at the moment of ignition it can be seen as a small flame flashes and goes out, sometimes it is without any problems with a normal flame. I also noticed that the flame on the burner happens
of different strength. I thought it was associated with the temperature of the coolant, but with several inclusions and shutdations of the boiler, the flame is different at the same temperature. The boiler was established what is called "as is", i.e. No settings were carried out. The only parameter that tried to change this parameter 220 "Smooth Rizhag" is the factory setting 47, I tried to zoom to 80 - the result did not give it back.
No more parameters changed. Still noticed that with an increase in the temperature setting to 61 degrees, the device does not turn off, i.e. He gradually as approaching the temperature reduces the flame and continues to burn in this mode. When setting the temperature of 53 degrees, it was heated and disconnected, but then it cannot start the above problem. Find a specialist in such boilers in our outback
it is impossible, and to the nearest center 200 km. Can someone come across a similar problem? Advise what verification operations must be done to identify a malfunction.
It is necessary to slightly increase the minimum gas pressure on gas. valve. Dogery to a given temperature, occurs on the min. pressure. Adjustment (handle) of the DHW - to the maximum. The duct must correspond to the maximum (12 l / min). The first measurement, (by gas) at the entrance, in statics, then on the start. If, the pressure drops, less than 14 mbar to the valve do not touch, otherwise you will somete all the factory settings.
Tell me, I have a wall-mounted gas double-circuit boiler Ariston Class 28 CF. When the DHW is turned on, the water temperature does not correspond to the temperature displayed on the screen. At first, I did not pay attention to this, but the recent times the testimony is very much dismantled, exhibiting 45, and flows, about 38. How to fix? Can I repair it yourself?
Need to check and maintenance with full cleaning.
After turning on the boiler (in heating and DHW mode) green LEDs 50/60/70 and the yellow LED house, the boiler does not burn. What to do?
This error is the presence of a flame with a gas valve (false flame). Fee need to be repaired.
I have a wall-mounted boiler EGIS II 24 FF for three years of operation. During the year, a fan relay was out of order several times what is the reason? The fan constantly works!
Shipping contacts. Perhaps the propeller is seriously rotated, because of this high current through contacts. Try to put a relay with a lot of current. (More than stood) Current on the relay case is specified. Even check the contacts of the fan connector on the board and contacts on the fan itself - perhaps somewhere contact is not very good-because of this and the relay does not work for a long time. In the boilers of this series, the reconfiguration of this parameter (protection from
the hydroudar) is not provided for any of the three modifications of the management board.
The boiler is new. For some reason, the outline of the DHW does not work. Heating is working fine. On an attempt to turn on hot water, the boiler only shows the temperature, and he is not even going to warm, waited for about 5 minutes.
Problem in the three-way valve. Put water caliper - spoiled the mechanics of the servomotor. You need to change both.
Installed wall gas boiler BS II 24 CF NG. When the DHW is turned on, the yellow light lights up (T-40)., And then it starts flashing. Water warms fine, heating works, in general, everything works. There should be a light bulb or some kind of system failure. When heating and DHW, it burns, does not blink. I was told that one should not be, I should just burn. The boiler has just been afraid of failures in winter.
The boiler was installed in this spring, there were no problems. Now there is a rather strange breakdown - an error 5p3 appears (flame separation). Moreover, the error appears only if the temperature of the heating conserve is below 60 degrees (the device tries to start, the ignition is heard, the burner icon appears on the panel for a second, then it disappears and pops up an error). If I exhibit 60 and higher degrees, the problem goes. What could it be?
This error 5p3 on these boilers may occur due to the pulsed power supply installed there. The potential that sees the ionization electrode occurs as a result of burning occurs with the potential of the boiler itself (which will be more than 5V) if it is not grounded, this error may occur. A specialist can test this by disconnecting the "Earth" wire from the main control board and restart the boiler at the temperature you need. The error should disappear. If this did not happen or you have a boiler grounded. You need to watch the gas valve settings.
In operation Gas boiler Ariston Egis plus 24 FF. When you open the hot water crane, almost immediately after discovery, it starts to go cold, then hot seconds so 20, and again cold, the hot the same approximate 20 seconds, and again cold, and so continues to infinity. On the display gas boiler ERR 109 is displayed, judging by the instructions, this is a "crawling text failure." Can tell you what is the test than
an error may be called, and how to fix this problem?
It is necessary to carry out the maintenance of the boiler.
Tell me about connecting a room thermostat to the boiler. I did everything according to the scheme that was attached to him. To begin with, leaning the jumper, the boiler did not start - this is normal! Connected a room thermostat, the device did not start, but when scrolling the handle, somewhere more than 23 degrees was a click in the thermostat, the boiler began to work, but turns off and turns on, without reacting to the thermostat. I tried to throw over the thermostat
terminals, on the contrary, the device turns on up to 23 degrees, when turning the handle of the thermostat, a click and a boiler turns off, but also in this position it does not react to the thermostat. Who knows, tell me, maybe that's wrong!
Probably disconnected due to overheating of the coolant above the ordered temperature. Add temperature on the boiler.

Dual-circuit gas devices make our lives more comfortable and pleasant. They are quite practical in use, suitable for heating country houses, and small apartments. Used for heating production or warehouse buildings, which are no more than 500 sq.m.

The advantages of Ariston boilers is that in addition to heating buildings in the winter, they heat the water used in everyday life. round year. It is quite convenient and does not require the installation of additional equipment.

General Characteristics of Ariston Boilers

The description of the ARISTON gas units should be started with the characteristics of their main part - burners. This element serves to burn fuel and for the impact of thermal energy into the heating system.

Types of burner boilers:

  • normal
  • modulation

Modulation burner is more convenient to use. It provides automatic power regulation depending on the temperature of the device.

By type of removal products combustion, burners are divided into:

Units with a burner of a closed type are safer in operation. Natural gas combustion products in this case do not fall into the room. The use of chimney is not required. The device is simply connected to the device. coaxial pipe And bring it out.

The design of the coaxial pipe provides for the presence of two layers, which ensures the simultaneous conclusion of the ugon and air flow from the street in the burner.

Equipment with an open burner provides for the mandatory use of chimney to remove combustion products.

Technical data of ARISTON gas devices

  • ARISTON boilers are used for heating and heating water, that is, they are two-circuit. Each modification has its own features, but the type of fuel is gas.
  • The gas combustion chamber can be either an open type or closed. In the presence of chimney, units with an open camera are used. And in the apartments multi-storey houseswhere there are no chimneys, use equipment with a closed combustion chamber.
  • Power. With this indicator, the gas consumption required to heat the room is calculated.
  • Compactness. Wall instruments are used in small, narrow rooms. Floor units used in industrial or warehouses are heavier and require a larger space for installation.
  • The presence of a control unit. This element is indispensable when the water is turned off, a sharp reduction in gas. For any work disorders, the block will turn off the device, which will prevent breakage. It can also be saved by fuel consumption.

ARISTON boilers are used for heating and heating water, that is, are two-circuit

Characteristics of ARISTON boiler models

A distinctive feature of Ariston boilers is their high quality. After all, the company name is translated from Greek as "best."

Its products are especially popular among consumers with an average income. Gas boilers of this brand are purchased for heating rooms up to 500 m.kv. Products are universal. The transition to a liquefied type of fuel is carried out only by replacing the burner.

Practical in use are two-circuit wall gas appliances. It is represented by three lines, each with its modifications.

For all modifications of boilers, the general is:

  • small size.
  • the supply of hot water, in the absence of its centralized feed.

Gas boilers of different modifications differ among themselves the structure, the general is their low cost and high-quality performance.

Basic equipment of aggregates from Ariston:

  • double heat exchanger.
  • electronic control module gas burner.
  • control of carbon monoxide.
  • support for microclimate in a building or in a separate apartment.
  • control freezing of water inside the system.

Consider more existing types of ARISTON equipment.

ARISTON GENUS.

  • Produced with a double heat exchanger. All modifications are two-door and mounted on the wall.
  • This model is considered the most functional of all ARISTON devices. It has a LCD display, the control panel on the buttons. Ariston Genus can be customized on the offline work for a whole week.
  • The display shows the basic data on the state of the device and list possible errors. The burner is modulated, that is, completely controlled by electronics. This feature increases the comfort of the use of this model of the gas device, due to the minimum control from the consumer.

Ariston Genus line includes EVO models and more expensive Premium.

The EVO model is a two-round gas device with a burner of both types: open and closed.

Genus Premium. condensation boilers. Used for heating residential houses and commercial destination buildings. Capacity range from 24 kW to 35 kW.

Ariston Clas.

  • Device of small sizes.
  • This is a boiler with two contours and elegant appearance. Reduced dimensions did not deteriorate its functionality.
  • Expansion tank for 8 liters. Hot water heating occurs fast enough

Existing modifications:

  • EVO is available open and closed combustion chambers. Power with an open burner - 24 kW, with closed - 24 - 28 kW.
  • Premium EVO Condensation Device. Has extended comfort and freezing functions
  • Premium Simple condensation unit.

Ariston Egis.

  • It is installed mainly in rooms of up to 200 m.kv.
  • Our most common ariston gas instrument model. Heats the water with a stainless steel heat exchanger, and a copper heat exchanger is used for heating.
  • The compact device is characterized by economy and can be used with complicated weather conditions. For example, with sharp minus temperatures.
  • The device is equipped with a gas burner modulated, which allows electronic control over the work of the boiler.

This model is adapted to work in harsh climatic conditions. It normally withstands gas pressure drops. The device is equipped with a collection in which condensate flows. This provides operation at temperatures below 50 degrees.

\u003e Cost of ARISTON boilers

The average cost of Ariston Genus boilers is 54,000 - 72,000 rubles, Ariston Clas - 25000 - 34,000 rubles, Ariston EGIS - 27000 - 34,000 rubles

Choose a gas device for heating

Ariston products can be found in the catalogs. There are many models gas devices. Basic errors in case of incorrect selection of the unit are made from lack of information. Therefore, before visiting the store, you should familiarize yourself with the main tips on choosing a wall gas device.

Choosing a boiler, take into account the following points:

  • The size of the kitchen, as the place where the heating device is most often installed. In the store, the choice starts with the consideration of the overall dimensions of the device and select it individually for your kitchen.
  • Next, go to the technical data and study the type of water heater in the device. If in the family a large number of people, it is not recommended to acquire a boiler with a flow water heater.
  • In this case, more rational to purchase a boiler with a cumulative tank for hot water and choose the equipment to the amount of water that you will need for everyday use.
  • Rate the combustion chamber gas equipment. It happens closed and open. It is recommended to choose a boiler with a closed camera, due to the fact that it is more secure in operation. The presence of chimney is not necessarily important in multi-storey houses. Enough to buy and take a coaxial pipe to the street.

The most frequent error codes and troubleshooting methods

Amiston's most popular among boilers are wall-mounted models by 24 kW. In the process of operation, the gas of the ARIRISON boiler may occur faults and malfunctions, as in any other technique. The list of error codes is given in the instructions in the form of a table. Some of them are a collection of automatics (call a protective disabling of the machine) and are eliminated by pressing "reset", and some signals about faults and interference in the boiler operation and require interference (block operation of the system).

All codes are divided into six groups by the number of boiler nodes. The first meaning indicates the node in which the failure occurred, the remaining error -code. But it should be noted that if the protective error is repeated often, this indicates a malfunction.

Most frequent from them:


Ariston Clas Evo Boiler Control Panel

  • error 501 - no ignition. Check if the gas valve is not blocked if there is a feed, you should pay attention to the ionization electrode, it can get wet, dried with a hairdryer. Look, if it did not rendered, the distance from the electrode to the ridge should be 8mm with a 1mm tolerance, whether the electrode compound is qualitative;
  • error 607 - sticking the contacts of the fan control relay, will help replacing the relay, and sometimes the entire electronic control unit.
  • 101

    Error 101 denotes overheating, the sensor is triggered, after cooling the boiler starts. The reason may be the accumulation of scale in the heat exchanger, as a result of which the duct decreases and the temperature increases, or interruptions in the operation of the circulation pump. Rinse the heat exchanger, adjust either change the pump. Sometimes the reason can be wounded in an enlarged gas supply, screw the valve, if it does not help, you need to adjust the gas valve.

    103,104,105,107

    Error 103, error 104, error 105, error 107 occur in violation of water circulation in the circuit, its absence or low pressure. This happens when the air has accumulated in the system, to remove it in the ARISTON EGIS Plus 24 boilers (Ariston Egis Plus 24), press and hold the MODE button for 10 seconds. On the boilers, Ariston Mathis and Ariston Unwanted the Rezet button no more than 6 seconds. For 5 minutes a pump will operate without ignition, removing air from the system. Then check the pressure, the rate of 1-1.2 bar, if necessary, increase.

    Copper Ariston EGIS Plus 24

    108

    Error 108 appears when insufficient pressure Water in the heating circuit. Why pressure drops - the cause may be leakage of heating radiators, it is necessary to check the locations of the connections in the pipes. In the heating season, it will notice a small leakage will not be easy, as it will evaporate a small sublock on hot batteries. You need to turn off the heating and add pressure to 2.5 bar to determine the seat of the subsidiary.

    The next reason may be the leakage of heat exchanger pipes. To eliminate, the heat exchanger can be selected if the soldering is impossible, it is required to replace it. An expansion tank can be deployed or an indestructible membrane in the expansion tank - seal the tank or change the membrane.

    It can flow and the tank itself - it is possible to determine this by pressing the spool in the upper part of the tank. If at the same time the water is released, change the tank. How to lift pressure - you can use a homemade original device consisting of a plastic bottle, crane and spool. On a plastic bottle, cut on the cover with the help of a thread tap so that the crane can be fixed on it.

    From the reverse side, drill a hole to fasten the spool on it. Spool we get into the bottle and fastened. Pour water into a bottle, close the crane and connect the heating system through the hose, we connect the pump to the spool and, shaking it, overflow water into the heating system. The procedure for pumping water into the system repeat to normalization of pressure, up to 1.5 atm.

    109

    Error 109 appears when overweight Above 3 bar and is considered one of the infrequently cases. To eliminate, it is necessary to reset the pressure, as it is written in the instructions for the device, with the help of the crane Maevsky. If it does not help, most likely, the reason lies in the secondary heat exchanger.

    When the partition is destroyed inside the heat exchanger, it can be fistula in it, the mixing of fluids begins. Water from the water supply, which has a higher pressure, begins to enter the heating system, resulting in pressure. What to do if this happened - the setting of the fistula or the replacement of the heat exchanger will help solve this problem.

    117

    Error 117, according to the instructions to the aggregate ariston BS 24 FF, means insufficient circulation. To eliminate, press the reset button, in this case the system will check and adjust the temperature difference at the inlet and output of 3.5 degrees for 8 seconds.

    RESET button on the boiler Ariston - "Reset"

    201

    When breaking the chain or a short circuit of the sensor on the feed in the contour of the hot water, the 201 error appears. You can check the contacts, perhaps they oxidized, or the wire departed, or the sensor itself was defective and it will have to be changed.

    302

    Error 302 appears on the display in the absence of a chain between the control board and the display. The reason may be a violation of contacts or their oxidation, in which case the contacts should be connected or read. There may also be due to the control board - replacement.

    303

    Error 303 means a malfunction of the main control board, solving the problem can only be replaced.

    304

    Error 304 also appears in the event of a malfunction of the control board and appears if more than 15 recesses are performed for 15 minutes.

    Boiler board Ariston

    307,308

    Error 307, Error 308 also appears in the event of a malfunction of the control board, correct the situation will help pressing the Reset button.

    501

    The code 501 is described above in the section most frequently repetitive errors.

    601

    On ARISTON EGIS Plus 24 models (ARIRISON EGIS PLUS 24) CF, Class 24 FF and others, with an open combustion chamber, error 601 means the absence of thrust. The sensor blocks the column operation in case of interference in the smoke removal system.

    This blocking is temporary, after 12 minutes the system will switch to the operating mode if the reason is eliminated, otherwise repeated again. To eliminate, clean the chimney if the chimney is free, check the help of the thrust sensor.

    604

    Error 604 occurs with a low frequency of rotation of the fan or malfunction of the Hall sensor. You should check the fan and the sensor if you find a breakdown, replacement is required.

    Hall Sensor

    607

    Description The causes of the occurrence and the removal method is described above, in the most frequently repetitive errors.

    a01.

    Error A01 blocks the boiler operation due to automatic ignition failure. It may occur with low unstable voltage on the network, set the stabilizer. Can affect the polarity, in some cases the problem can be eliminated, changing the polarity in the outlet, turn the plug, change the phase to zero.

    In addition, problems with the ionization sensor of the flame are possible. Check if it is not clogged, it is not bent, it may have broken or the wire connecting the sensor with the board was broken. Sleep or clean the wire.

    e34

    ERROR E34 means a fleecylet failure with a fan running. What to do - check the relay and replace it if necessary.

    e108.

    ERROR E108 means a drop in pressure in the heating circuit. The reason and solution of the problem are described above in the description of code 108.

    sP2.

    Error SP2 (5P2) means that the second ignition attempt is unsuccessful. If the boiler does not start, the reasons may be somewhat - there is a problem in the ionization sensor, reduced gas pressure, insufficient air inflow, removing combustion products. Check the performance of the sensor, possibly closed or the gas crane is not open enough, open the window and door, check if the chimney is not clogged.

    Ionization electrode

    sP3 (5p3)

    This malfunction code is described in frequently repeated errors.

    1p1.1p2 (IP2)

    Error 1p1, 1p2 (IP2) appears in the case of poor circulation of water or its absence. Causes and solving the problem are similar to Code 108 and are described above.

    6p1

    Error 6p1 appears when there is problems with air and smoke removal, a relay is delayed. To eliminate the problem, check whether the air enters the room where the boiler is installed, whether the chimney is not clogged, whether the relays are not covered.

    6p2.

    The 6P2 error also occurs when problems with smoke removal and air flow, while opening the contacts of the combustion products pressure relay during the normal operation of the fan. The solution to the problem is the same as when the code 6p1 appears.

    Pressure Relay Boiler Ariston

    Other breakdowns

    In addition to those described above, such codes may appear:

    • 608 - the system issues such an error when the fan earned, but the press service did not work.
    • H45 - two recent digits can change. The reason lies in the NTSC sensor, there is no hot water at the output, the safety valve leaks. If there is no hot water, but the heating system works, most likely the water flow sensor is faulty, the garbage has been driving.

      Another reason can be that the blades of the turbines have greatly worked, stuck to the body, it can be a hindrance of rotation, replace the blade or the Turbine itself.

    The second reason in such a situation can be the NTC sensor, to check its performance, measure the multimeter resistance on its contacts, if it is unstable, replace the sensor to the new one. If a safety valve occurs, the gaskets may be worn out, replace them.

    NTC Sensor

    How to determine the error code if there is no display on the device or without a dial, how for example, on the ARIRISON BS II 24FF model? Such a device is equipped with light bulbs, thanks to which you can define a breakdown. For example, if the indicator 90 is lit and the crossed out of the water drop icon, this means that there has been overheating and blocking the boiler. To eliminate, check the press service and its connection to the board.

    Search for breakdowns and faults at the ARISTON BS boilers

    Gas boiler Ariston BS 24 can not start. When you hold the on / off key, the burner device works. If you press the key, the unit immediately swings. Tell me the cause of the breakdown?
    Probably, the thermoelement or breakage of the gas valve failed. A low gas pressure may also occur at the input pipeline. Sometimes there is a lack of voltage of the electronic board.
    Recently a malfunction arose. Start is done very hard. Opt device It is lit, but there is no main burner fire. I can not understand what is the reason?
    Apparently, damage to the parts of the ignition node. You must perform the service of the unit and clean the incitement device.
    Why does the ARISTON BS 15 FF wall boiler stopped disconnected while setting the set temperature? Heating is up to 85 degrees, then gives breakdown. After the restart operation, the cycle begins again.
    Apparently, the fee is not in order, the thermal sensor has a malfunction, the overheating protection button broke. It is possible that the automation setup fails.
    I would like to know for what reason the boiler does not heat the water above 70s? I need to set more, but the screen gives out that this is the maximum parameter. How to increase heating?
    In case the device does not increase the temperature of the heating circuit, then the following factors can be assumed. The settings set a limit to the maximum heating temperature not higher than 70c. There is a decrease in thrust in chimney.
    ARISTON BS II 24 FF unsatisfactorily performs functions in the mode of heating the DHW system. Cold water follows from the crane, then hot. Tell me, because of what this malfunction?
    The factor of the problem may be such. Cold water is mixed due to the fact that the three-way valve has failed. The heat exchanger is littered. You need to clean it.
    Under the boiler there is a crane, the water flowing regularly occurs from it. The unit itself does not work. What do you need to do?
    Apparently, there is a discharge of the coolant from the safety valve. This feature indicates an increase in pressure in the system. In addition, there can be an open system feeding the system or you should swing the extender tank.
    Explain that for what reason the pressure increases hard, and at the same time the protective valve opens? The screen always highlights the heating icon in the heating cycle of the instrument. What to do?
    There is a breakdown of the temperature sensor of the heating circuit. There is no normal circulation in the heating line.
    What is the breakdown when the Gas 24 FF gas boiler was constantly disconnected? Let's say, today the ignition is absolutely unable to work. Maintenance of the boiler did at the beginning of the month. What could be?
    We can assume that there are malfunctions in the decay device. You must complete the chimney. Incorrect electrical engineering operation will mean damage to any part in the event of a voltage or water penetration.
    Please help figure out the chimney pipe? Already 2 days a reverse thrust appeared, while the smoke began to fall directly into the room. Chimney I made myself. It consists of metal pipe. It seems that an error is made in the calculations.
    The boiler works great on the DHW, and when you turn on heating, water quickly comes to a boil, and the device stops working. What is the malfunction, and how to eliminate it?
    It is possible that the circulation pump is inoperable, the control failure failed, the thermal sensor is faulty. Also, the filter grid was hampered.
    At the DHW stage, the unit alternately began to issue it cold, then hot water. Help me understand what it happens. How to adjust water heating?
    Apparently, the heating system is dirty or it is necessary to clean the heat exchanger. In addition, a malfunction of the pressure control sensor is possible or the circulation pump is faulty.
    The main reason may not be correctly made the configuration of the chimney channel. Sometimes the pollution of the soot, which sufficiently lowers its efficiency. In addition, it is recommended to check the ventilation indoors.
    In the work of the Gas Copper Ariston BS. The device instantly produces a set of temperatures up to 96 s, and after overheating. In the future, when it is cooled, it turns out to be rebooted. How to eliminate breakdown?
    Failure of overheating functions denotes the lack of circulation in the system. Mainly, it is necessary to control the position of the cranes of radiators. They must be opened. After checking on the contamination of the filtering element, it is also necessary to make sure whether the heat exchange device does not contain the mud.
    Performed the connection of this unit in 2015. Approximately after 2 months the device sharply became noise. Explain why noise occurs?
    Most likely, there is a scale in the heat exchanger. If the water is rigid, then with time on the walls of the radiator pipes, lime will be postponed.
    I am going for heating at home to connect the ARISTON BS II 15 FF boiler. Tell me, please, how best is it necessary to run it into operation?
    For a correct start in the operation of the boiler device, you must make subsequent actions. We connect electrical power to the instrument. Open gas faucet. Then we launch the burner device. After adjust the desired temperature.
    We want to carry out maintenance. Advise how to drain the heat carrier from the device?
    In accordance with the manual, this work is done like this. Turn off the device from the network. Close the gas valve. We open the automatic air vent. Open drain crane. Next to collect the spilled water. In another case, you can merge water using a reset valve. This valve is placed at the bottom of the device.
    Explain to me how to diagnose the 3-way valve? I think he incorrectly opens. On the heating mode, weakly pumps long-distance batteries, but the pipe is heated on the DHW. heating water Under the boiler unit.
    It is true, it is necessary to inspect the three-way valve for the presence of rod watering in an intermediate state. We also recommend diagnosing the heating itself.
    I have functions in the house of the boiler BS 24 CF. Until this time served as well. Currently, after 1 minute after the start, the device sweeps.
    It seems that he can't catch water into the system. Explain that this is for the reason? The probable factor of this damage may be an ignition electrode that does not see the flame, or the lack of circulation.
    Literally yesterday, a nuisance was revealed with this unit. When working, he began whistle. I tried to restart - it was possible, but the changes did not happen. Perhaps someone will say what is the problem?
    Very often a sharp whistle occurs when the pressure setting on the nozzles of the gas melting device is incorrectly. You need to check the gas pressure adjustments and correct if necessary.
    Water recently flooded in the boiler, and the unit began to function with errors. For example, if you adjust any temperature, and the heating mode reaches exclusively to 22 degrees, and then the unit stops. Could you tell me what happened?
    In case of water from entering the control board, it can be assumed that it works not correctly. Let us advise you to reset it by completely shutting down the unit from the power grid. Then re-enable and experience its performance.
    We introduced two years ago to operation the device of the same model. Today, at the time of start, the phytyl burns 8 seconds, but the main burner does not support the flame, and because of this, the device swings. How can I fix the breakdown?
    Probably faulty melting machine or burner problems. In any case, it is necessary to check if the phasing was not disturbed at the time of connection to the electrical network.
    Completed independently in the middle of this year, commissioning the same model. Somewhere 4 months later, a failure in the DHW circuit emerged, but the heating mode acts normally. I tried to open the crane of hot water, but the device is only depicting the temperature, and it does not even think to heal. Why does the DHW do not work?
    Most likely, a 3-chassing valve is faulty. It must be replaced.
    Tell me, why the boiler is equipped with a safety thermal sensor?
    This part overlaps the flow of gas for the burner, with the overheating of water in the main heat exchanger.
    It is required to rinse and clean the primary heat exchanger. Tell me, what should be done in order to qualify it to disconnect it?
    The main heat exchanger is easy to remove from the boiler unit when using a conventional screwdriver. Below is the procedure for dismantling. We carry out the drain of water from the device, using a trigger crane. Then empty gVS system. Remove the fastener screws of the heat exchanger and pull it out of the frame.
    Performed the start of this unit. Presumably three months later the water pressure decreased in the device. Often he slows him and stops working. In other words, absolutely does not keep pressure. Why is this happening?
    If the device does not increase the water pressure, probably flows the fuel tap. When the water is turned off and the water pressure drops sharply to zero, then the 3-way faucet is damaged.
    Tell us how to clean the cold water filter?
    The initial stage is to drain the water from the DHW circuit. Secondly, unscrew the nut of the flow sensor. Then give the sensor and the filter from the cavity. After that, we clean from the accumulated impurities and dirt.
    The device when started and previously could buzz, and at this time the noise is much louder. Initially, the sound quickly disappeared, now it keeps longer. Someone observed such a problem?
    The appearance of excess noise indicates the presence of mineral deposits inside the heat exchanger, the heating of which occurs unevenly due to the different wall thickness. The more heat exchanger is polluted, the more distinct the root, and the heat transfer is reduced accordingly.
    The unit functions, although in the water system, apparently does not circulate. The pump acting on the return is noticeably heated. How to fix it?
    Apparently, the filter-mud filter or somewhere closed the crane, which prevents the passage of the coolant. Circulation pump may also be faulty.
    What does hot water cease to warm up? Water flows completely warm. Explain what happened?
    Clarification of problems lead in the following directions. In case of damage to the DHW temperature sensor, it should be replaced. It may have occurred the power settings of the device for heating DHW.
    Periodically browsing the flame break during the incitement. The burner is clean, everything is fine with chimney, the thrust is good. What could be a malfunction?
    The unit does not define a spark due to a weak signal from the combustion mechanism. Here it is necessary to check the wire between the ionization sensor and the electrode. Probably need to pull it up. There may also be damage in the insulation of the sensor, which is subject to replacement.

    • Gas boilers
    • Electric boilers
    • Bug codes Boilers
    • Troubleshooting boilers
    • Gas speakers
    • Faults and repair of gas columns
    • Water heaters
    • Troubleshooting Water Heaters
    • Repair of indirect heating boilers
    • Elimination of electroconvectors
    • Baxi Eco Four.

    Control of the heating system. Installation. Connection. Translation to another type of gas. Adjustment devices and protection devices.

    • Baxi Luna.

    Features. Installation and installation. Automation components.

    • Baxi Main Four.

    Technical specifications. Installation. Adjustment and verification. Maintenance.

    • Baxi Slim.

    Adjustment and protection. Installation and installation. Pressure setting. Maintenance.

    • Buckuck - Repair

    After starting, a malfunction appeared. It does not want to turn on, worked for two years, now it caught fire all the scoreboard as when the boiler is turned on, when the self-diagnosis mode goes on, then clicks, it turns off on miles sec and again includes all the scoreboard. Once it turned on, but it gives an error E10 water pressure, although the pressure in the system is 1.5 atm. Tell me, what could be?

    • Buckuck - Operation
    • Bakcy - Settings

    Installed and connected BAXI FOURTECH 24 F Copper. What cold water pressure is allowed at the entrance to the device for DHW?

    • Bosch - Repair

    Bosch boilers 6000 24 kW, single-concert with built-in three-way valve. Does not see the boiler sensor, gives an error. Tell me how to make a mistake not to give out and worked fine on both heating and boiler.

    • Bosch - adjustment

    If you turn off the DWP duct sensor, can it be possible through the L3 menu to reprogram in a single-circuit machine?

    • Arderia - repairs

    Installed ARDERIA ESR 2.13 FFCD boiler. If I have a slightly pressure of the coolant for 2-3 days by a couple of divisions, can there be a cause in a threshold valve fault (no leaks from radiators)?

    • Arderia - adjustment

    In operation Gas boiler Ardery 2.35. Tell me about a reduction in power. I heard something about modulation, the speed of rotation of the fan and so on. Is it possible to really reduce the power?

    • Buderus outdoor

    Installation and connections of the boiler Buderus Logano. G234-WS-44 kW, Automation of logomik 4211. Heating on cylinders without DHW, also replaced jets for reduced gas. Winter survived, the cylinders were replaced, everything without problems. Then in the spring, when the temperature on the street + 16 + 18, the boiler began to turn off for a long time and when turned on, it began to give the burner error on the screen and the red light bulb on the front wall lights up. Pressed the button, re-turned on the power and everything worked. Several times it was, then for the summer turned off the boiler completely, what could be a malfunction?

    • Buderus wall mounted

    In one-mounted Budyrus 072, the contour of the Kmeevik BKN is heated by the same heat exchanger that heating or the same as on the 2-contour which is on the DHW?

    • Vaillant - Repair

    Tell me, for Vaillant's wall gas boilers, is there real / actual differences for the better in the new generation of Turbotec Plus VU / 5-5 compared with / 3-5?

    • Vaillant - adjustment

    Malfunction in the work of the boiler, the green LED flashes (nutrition), the instructions say that worked heavy protection, the green indicator flashes, even if nothing is connected to the board. How to fix? Checked all SMD resistors and transistors, everything is in order.

    • Daewoo.

    In operation gas boiler double Daewoo Gasboiler with electronic panel. When the DHW is turned on, heating is heating, the mode of operation is summer. Removed the three-way valve, dirt and production. It seems that the board does not control the three-way valve. How to check?

    • Electrolux

    Installed and connected wall boiler Electrolux Basic XI. The problem has begun that the boiler stopped seeing the flame and turned off the gas supply in 7-8 seconds. And after 3 attempts issued an error E1. How can I fix?

    • Korea Star

    Koreastar boiler fault. Heating works fine, hot water goes with interruptions, when the hot water crane is turned on, cold water first goes, then boiling water. After a few seconds, cool, then boiling water again. What could be the problem?

    • Ferroli.

    Malfunction of the Ferroli Boiler Domiprode 24 - setting up 60-70 degrees, it goes to minimal burning, does not turn on, does not turn off. Re-launch is unstable. No regularity is detected. What to do?

    • Junkers.

    In operation, the Junkers Euroline gas boiler, when the hot water is turned on, it's gas, then goes well and so several times. If you turn on when working heating, the water heating is turned on immediately. Tell me, please, what could be the problem?

    • Navien.

    Tell me on adjustments of the gas boiler Navien Ace 16 turbo remote v1.3. It fails to configure the fan eating. I put 30 sec., But still 2 minutes. turns.

    • Oasis.

    Fault of the boiler Oasis ZRT18. The unit is started, gas is lit, then flies. Again ignites, goes down (three times it happens). Then it flares up and works fine. No error gives out. What is the reason?

    • Saunier duval

    Fault Gas Boiler Senor Duval - Water Pressure Sensor Shows 0.0, the indicator flashes in red, hot water is not heated, but at the same time the water pressure in the apartment is good. How to fix the problem?

    • Viessmann.

    In what place of the coaxial chimney should a condensate trap? The WH1D boiler with a closed combustion chamber is located at a distance of 1m from the wall.

    • Westen.

    The problem of launching the boiler Westen Pulsar D. Piezo Razhigig is triggered, but there is no flame, after the cod error E01. The plug has rearranged in some places.

    • Beretta.

    Outdoor gas boiler Novella blocked - green light bulbs on the panel are burning, and nothing happens more. How to fix?

    • ARISTON.

    The ARISTON gas wall boiler is installed and connected, which does not hold pressure at all: during cooling heated water, the pressure drops to zero, although water is regularly recruited. What with pressure?

    Metropolis DGT 25 BF Boiler Fault. WVS stopped working, heating works, the error does not give out. What do you advise?

    • Solly

    Tell me, please, how to solve the problem. The boiler Solly Standard, with any attempt to turn it on or hot water, gives the GS error.

    In operation Copper Wolf. Recently, he became strange to lead: in a pause between the launches, five times turns on the burner for one second, and 70 degrees pop up on the display. Where to look for a fault?

    ACV Wester Line works very unstable: often goes into an accident, when starting, a characteristic knock is published and stalls, and at times everything is fine. The unit is almost new, what's wrong with him?

    • Demrad.

    In the gas boiler, Demrad stopped serving gas for the burner. Piezo element clicks, but the ignition is not. FROM gas stove Everything is in order, gas is. What is the reason?

    • Kiturami.

    Malfunction of the Kiturami World Boiler, stops periodically. I wipe the flame sensor, and the device works well for a while, but soon everything is repeated. He also began to smoke. Maybe it's a short chimney, and you need to lengthen it?

    • Immergaz - Errors

    Nike Star boiler errors, Eolo Star / Mini, Mythos. Faults of boilers with the ability to automatically unlock.

    • Immergaz - Repair

    My boiler in winter mode systematically raises the temperature to 80 degrees. Three times called the masters. He said that this is many models of Imergaz, and suggested putting a programmer, but not a fact that it will help. Tell me how to solve this problem and will this program guide?

    Models 11.6; 17.4; 23.2; 29.3 kW. Specifications. Automation block controls. Installation and maintenance. Faults and their elimination.

    • AOGV - Repair

    Installed and commissioned Gas boiler AOGV. The problem with the feed of hot water. The heat exchanger was washed. It took less than a month, and the water does not go again. Put the filter on the water, but time passed, and again it does not go hot water. What could be for breakdown?

    Installation and installation. Running and adjustment. Faults and ways to eliminate them.

    Technical specifications. Installation and connectivity. Running and work order. Adjusts automation.

    • Neva Lux

    Malfunction of the Cable of Neva Suuxen 7023. With periodicity 2 times a month issues an E7 error. But after the reboot, it works. Now issues an E6 error. It will work for 15 minutes, and turns off. What could it be?

    Construction and automation unit. The order of ignition. Faults and repair.

    • Atham Zhytomyr

    Saying whether it is possible because of the weak pressure of the gas boiler Atham Zhytomyr swings, it clicks on and flies. What is the problem? Is it possible to disable automation on time and how?

    • Lemax

    Mounted gas boiler Lemax KSG-12.5 Premium. After disconnecting the main burner in a couple of minutes, click on, what is the reason tell me?

    • Keber

    The KS-G gas boiler is installed and connected, for 250 sq. M. When inciting it, it does not turn off, the temperature rises, if I'm not mistaken, the automation of Arbat 1. Not regulated by the flame is too large. What to do?

    Installed the gas boiler Lighthouse and connected it. It works fine. But the reason is that. When it works on a unit, it is very sick, if the regulator turn 2-7 squeak disappears. Tell me, what could be?

    • Danko

    Installed and connected the gas boiler Danko with automatic kara, it works perfectly on the stall, but it is worth adding power on the burner, it fully fades, yesterday it faded for 5 minutes, today it works for about 20 minutes and completely flies. Who faced such a problem?

    • Gazlyux

    In the operation of the Gazeco 18 boiler, when the hot water is turned on, the pressure drops in the system after feeding the pressure comes up to 3 bar. Have to drop. What is the matter how to fix?

    • Nova Florida.

    Water often boils in the boiler, while he goes into an accident on overheating. The heat exchanger is recently soap, the system is not clogged. What's the matter?

    • Rinnai.

    Malfunction of the RINNAI 167 RMF boiler. Recently began to show an error 14. How can I remove the breakdown?

    • Celtic.

    Cotelet Celtic DS heats up to 45 degrees and stands all day not turning off and does not heat the battery, sometimes shows an A3 error. How can this problem be eliminated?

    Each owner of his house is trying to make it as cozy and comfortable as possible. To achieve this, it is worth thinking about the installation of a double-circuit wall gas boiler Ariston, which will help solve problems with the heating of residential premises. The device is very useful in that it will ensure heat both in an apartment and a private house with an area of \u200b\u200bup to 500 m².

    Also, the gas wall-mounted boiler of a dual-circuit type of ariston will allow you to quickly heat the water for instant use. In this case, a person does not have to connect a boiler that will require additional investments and a separate place to install.

    Descriptions of the double-circuit boiler Ariston

    To date, the market of gas boilers can find many interesting models. This is quite convenient, as everyone can choose a device, as suitable as possible, at the price, species, characteristics and installation method. Double-circuit wall boilers Ariston were popular because of rare situations with their malfunction, as well as silence when working, which is very important to maintain a relaxing situation in the house.

    One of the most important components in all gas boilers is a burner, in this case it can be modulating or ordinary. The first option is greater popularity than the second. When using it, the entire system will be adjusted automatically, without human intervention. In this case, the power of installed equipment for heating depends on temperature indicators.

    The burner is also divided into 2 types:

    • open;

    The safest is, since it does not imply the burning of combustion products into the room in case of emergency. Also in this case, the owner may not worry about the construction of the chimney. To the closed burner, you must bring a special coaxial tube, it can always be output in any accessible place.

    Open-type ariston boiler, in any case, requires chimney to bring the combustion products to the street. Also do not forget about the natural thrust. The air will flow into the system from the dwelling, so it will have to constantly venture.

    Coaxial tube used in a closed combustion system is good for that feature that is made of 2 layers. One is necessary for the output of combustion products, and the other will ensure fresh air inwards inside the boiler. Thus, the equipment owner does not have to constantly ventilate the room and worry about natural thrust. The room will always have a sufficient amount of oxygen.

    Distinctive abilities

    According to the reviews of gas wall-mounted two-circuit boilers Ariston, they have 4 distinctive featuresuseful for their owners:

    1. All models of this firm are equipped with automatic protection systems.
    2. The presence of a water pump, which is necessary for constant circulation of water through pipes.
    3. The ability to choose to choose a model with an expansion tank. With it, inside the heating system, automatic pressure adjustment will occur.
    4. Ariston firm equips its equipment with various types of ignition. It can be automatic, which will greatly facilitate the life of the owner of a particular boiler. Otherwise, each time the unit is launched, a person will need to press a special button.

    What is the advantages of gas boilers Ariston

    Recently, the band's popularity of the Ariston has increased significantly due to high-quality gas boilers, and this is not in vain. It works silently and consumes fuel in the most minimal quantities as soon as possible. This will allow the owners of the aggregate to save on utility bills and, at the same time, to provide house comfort and warmth.

    The client will receive a high-quality device that provides round-the-clock water supply and heating at home even with a large area of \u200b\u200bup to 500 square meters. Also do not forget about the durability of the service of each boiler. The timelines specified in guarantees are much more modest than in fact. In size, equipment is much more compact than from other brands, it means that it is possible to install it absolutely anywhere, even in a small apartment with restrictions in free space.

    Specifications

    Almost everyone gas boilers Ariston's brand has a capacity from 15 to 30 kW. Thus, each client will be able to find the necessary indicators for the size of its apartment or at home. It is also worth noting the other distinctive characteristics Such gas equipment:

    • with the maximum efficiency of boilers have a high level of efficiency coefficient;
    • all wall-mounted boilers have Russian instructions and designations on the equipment itself, therefore citizens do not arise problems with the management of the aggregate;
    • most models from this manufacturer are able to handle the water in the system and reduced pressure;
    • special attention should be paid to those people, in whose homes there are often voltage differences. Boilers Ariston The devices are coping with such jumps on the network;
    • all models are very simple in management. To start using the boiler, you do not need to study the instructions for a long time, all the features of operation are intuitive and accessible even for those who establish such an aggregate for the first time.

    In some cases, the boiler cannot simultaneously heat the water and ensure sufficient heating of the room, this refers to budget models. In this case, a person needs to think about installing an additional boiler.

    Note! If we talk about expensive aggregates, they have a special display, which displays different characteristics, including the temperature inside the boiler and outside. It is very convenient in terms of making the necessary characteristics for the correct operation of the equipment.

    Operating Instructions Gas boilers Ariston

    Before purchasing a gas boiler, Ariston needs to be understood that if the buyer does not understand it, it is better to turn to experienced specialists and entrust all the work. After all, even with the most detailed instructions, it is not a fact that the case will end successfully. In this case, there are all the chances of damaging the equipment, after which they will have to cause repairmen, and this will turn out to be further expenses.

    It is very important to prevent children's equipment. For this, after, with them it is necessary to spend a conversation and explain to an affordable language that it is impossible to twist anything on the unit, only an adult should be engaged. If the family leaves, for example, on vacation, after the boiler is disabled, it is also necessary to block all pipes for gas and water. Only after that the equipment is disconnected from the network.

    If a display is provided on any model, all the indicators that it displays must be strictly monitored. It may cause problems or deviations from normal operation that occurred during the heating process.

    One of the most important points in the instructions for gas equipment is safety. Before connecting the boiler with it you need to get acquainted in the first place.

    What are the types of wall boilers ariston

    All boilers of the company Ariston are divided into 3 series. They have different technical indicators and functions, namely:

    1. CLAS - under this series, implies more cumbersome and powerful apparatus for the heating of residential premises. They are equipped with exceptionally special regulators that automatically adjust the gas supply. It is necessary to save fuel, which is very convenient from the point of view of utility costs and at the frequent business trips of the home owner.
    2. Genus. These are the most innovative and multifunctional models of gas aggregates Ariston. They have more opportunities than the remaining boilers from this manufacturer. Together with the equipment itself, the buyer will receive such additional accessories such as the fan needed for smooth adjustment of revolutions, as well as heat exchangers, primary and secondary. All devices from the Genus line are distinguished by the presence of a large liquid crystal display. It will displays all the characteristics that match the operation of the boiler at the moment.
    3. EGIS. Aggregates from this series have small sizes and attractive appearanceThan and deserved great popularity among the owners of small apartments. The device will fit well in any interior. An important feature of these boilers is that with its sizes they have a fairly high level of efficiency and a slight fuel consumption, which is controlled by an intelligent control system.

    Because of what a wall boiler may be faulty

    To the base causes of malfunction of gas boilers Ariston include the following:

    • During maintenance adjustment of the burner or control units, specialists made errors.
    • Unfortunately generated installation.
    • Purchase fake, which is distinguished by poor-quality components.
    • Lack of supply of sufficient air.

    Conclusion

    When buying one of the wall gas boilers Ariston, the seller needs to check the availability of all necessary documentation, which

    it will confirm that the equipment corresponds to the manufacturer. Only in this case, the problems with the device will arise very soon.

    Clas, Clas Evo, Genus

    Ariston Clas.

    Gas wallpapers Ariston Clas: 24 FF, 24 CF, 28 FF / CF, 15 FF / CF, 32 FF

    SIT 845 SIGMA gas valve - in boilers Ariston class Used SIT 845 SIGMA gas valve with two electromagnets that feed on AC voltage 220 V for supplying and cut-off to the burner. To regulate the gas flow at the outlet of the unit from the computer in accordance with the readings of the temperature sensors, low-voltage (24 V) regulator is used. This block is used both for natural and for liquefied gas. The valve is also equipped with a NAC504 product that serves the voltage to the ignition transformer of the main burner and the valve. Valve is designed to work with different gases without replacement component parts. Only nozzle is subject to replacement. Gas pressure at the inlet to the valve - no more
    6 kPa (60 mbar). Components: gas supply to the burner, pressure pressure sensor, nut adjustment nut, inlet pressure sensor, input fitting, ignition device, minimum power adjustment screw, compensator.

    Adjusting gas parameters

    Input pressure checking:

    Loosen the screw and plug the pressure gauge tube to the input pressure selection fittings.
    - Install the ARISTON CLAS 24 FF / CF, 28 FF / CF, 15 FF / CF, 32 FF, 32 FF to maximize operating power (GVS valve open). The gas pressure at the entrance to the apparatus should correspond to the passport for the type of gas to which the device is calculated.

    Checking maximum power in DHW mode:

    To check the maximum power, loosen the screw and plug the pressure gauge tube to the pressure selection fittings.

    - Run the device at the power maximum in the "Pediffle" mode (press the RESET button and hold 5 s.
    - The gas pressure at the entrance to the apparatus should correspond to the passport for the type of gas to which the device is calculated. Otherwise, remove the protective plug and adjust the pressure using the hex nut.
    - After checking, tighten the screw and check for tightness.
    - Install the protective plug on the knob.

    Checking minimum power:

    To check the minimum power, loosen the screw and plug the pressure gauge tube to the pressure selection fittings.
    - Disconnect the aircase compensator tube.
    - Run the Clas System boiler at a minimum power and disconnect the cable from the regulator. The gas pressure at the entrance to the apparatus should correspond to the passport for the type of gas to which the device is calculated. Otherwise, adjust the pressure using the screw while holding the fixed hexagon nut.
    - After checking, tighten the screw and check for tightness.
    - Connect the cable to the regulator.
    - Connect the compensator tube.

    Check power in soft ignition mode (performed using parameter 220):

    To check the power in soft ignition mode, loosen the screw and connect the pressure gauge tube to the pressure selection fittings.
    - Disconnect the aircase compensator tube (sealed camera).
    - Open the GVS valve. In the boiler Ariston Clas, burner ignition is performed. Disconnect the flame control electrode so that the pressure corresponding to the soft ignition mode is maintained for 8 s without a protective shutdown.
    - Change the parameter 220.

    Adjusting the delay in the power on the heating: adjustment is carried out using the 236 parameter. The boiler allows adjustment of the delay time from the receipt of the heating command to the ignition of the burner in the range from zero to 7 minutes. Regulation is carried out using the 236 parameter.

    Adjustment of the maximum thermal power: in the device there are two different values \u200b\u200bof maximum power: in DHW mode and, smaller, in CO mode (absolute maximum value). The absolute maximum thermal power value is set to parameter 230. This parameter is subject to verification and, if necessary, a change is exclusively in the case of transition to another group of gases. To regulate heat output in heating mode, it is possible to regulate the maximum thermal power (ranging from the minimum to the absolute maximum value). The boiler allows adjustment of the delay time from the receipt of the heating command to the ignition of the burner ranging from zero to 7 minutes. Regulation is carried out using parameter 236. Regulation is carried out using the parameter 231. The machine allows you to adjust the maximum thermal power value.

    Burner Basic - in the ARISTON CLAS 24 FF / CF, 28 FF / CF, 15 FF / CF, 28 FF, 32 FF, 32 FF, 32 FF, 32 FF burners with a pitch of 19.0 mm injectors. Electrodes (two ignition electrodes and one - control of the presence of flames) are combined into the block. The gap between the ignition electrodes should be 4 ± 1 mm, the distance between the electrodes and the burner is 8 ± 1 mm. Distance between the electrode of control of the presence of flame and burner
    Must be 8 ± 1 mm. In the absence of ignition of the burner after the protection time of the protective delay on the control panel indicator displays cipher 501. The ion current must be at least 1 μA. Voltage on the electrode relative to Earth 110 V AC.

    Ignition cycle. In CO and GVS modes, the ignition is carried out in two ways:

    DHW - If necessary, three ignition attempts are performed: 1st attempt - on the power corresponding to the soft ignition mode; If, at the end of the protective delay (8 c), the flame is not detected, the signal 5p1 is generated, the ARIRISON boiler Class 24 FF makes the second attempt; 2nd attempt - at the power of soft ignition; If, at the end of the protective delay (8 c), the flame is not detected, the signal 5p2 is generated; The device makes the 3rd attempt; 3rd attempt - at the power of soft ignition; If, at the end of the protective delay (8 s), the flame is not detected, the burner is turned off, the signal 501 is generated, the fan shutdown is delayed by 40 s, during which the fan operates on
    The maximum speed of rotation, then another 2 min - at the minimum frequency.

    CO - If necessary, produced three ignition attempts: 1st attempt - at 80% of the power corresponding to the soft ignition mode; If, at the end of the protective delay (8 c), the flame is not detected, the 5p1 signal is generated, the device makes the second attempt; 2nd attempt - 90% of soft ignition power; If, at the end of the protective delay (8 c), the flame is not detected, the signal 5p2 is generated; The device makes the 3rd attempt; 3rd attempt - at the power of soft ignition; If, at the end of the protective delay (8 s), the flame is not detected, the burner is turned off, the signal 501 is generated, the fan shutdown is delayed by 40 s, during which the fan operates at the maximum frequency.
    Rotation, then another 2 min - at minimum frequency.

    Electric I. electronic system Boiler Ariston Clas.

    The main board of the ECU - the device is used by the Galileo-MCU ECU. With it, all operations to control, manage and display on the LCD user interface display are performed. To protect the Galileo-MCU board, a fusible insert 2 A, 250 V alternating current and a varistor, smoothing voltage jumps up to 275 V. Power supply voltage 230 V + 10% -15%, compliance with phase and neutral when connected is not required.

    Connecting peripheral devices - the boiler allows connecting the following peripheral devices: room thermostat, timer - thermostat (also produced in wireless); room sensor (also available in wireless version); outdoor sensor; The remote control "Remocon" (also available in the wireless version).

    Menu 2: ARISTON CLAS SYSTEM Boiler Settings

    21 - Access code - turning the handle (counterclockwise), set the value 2 3 4.
    220 - Slowing ignition in% of the maximum thermal power - from 0 to 99.
    221 - the smallest switching temperature to the freezing mode (C) - from 2 to 10.
    222 - Adjusting the frequency of rotation of the fan - 0: prohibited; 1: Allowed.
    224 - Mechanical timer - 0: Disabled; 1: Enabled.
    225 - adjustment of the delay in the inclusion of heating - 0: prohibited;
    228 - boiler modification - 0: double-circuit; 1: with BKN;
    230 - absolute maximum thermal power - from 0 to 99.
    231 - maximum thermal power (as a percentage of absolute maximum thermal power) (%) - from 0 to 99.
    235 - Delay control mode - 00: manual (set by parameter 236) / 01: automatic (in Automatic mode).
    236 - Heating delay (min), allowed if parameter 235 \u003d 0 - from 0 to 73.
    237 - delayed circulation circulation in CO mode (min) - from 0 to 15; CO: non-stop.
    238 - Regulation of the frequency of rotation of the pump in CO mode - 0: Fix. Rotator frequency. 2; 1: Fix. Rotator frequency. 3; 2: Adjustable.
    243 - delaying of ventilation when it is turned off - 0: 5 s, 1: 3 min.
    244 - Forced heating (min) - from 0 to 60 (in the "Automatics" mode).
    247 - Pressure measurement unit in circuit CO - 0: only temperature sensors, 1: pressure switch, 2: pressure sensor.
    250 - "Comfort" mode of DHW - 0: prohibited; 1: Enabled within 30 minutes after the command on the DHW; 2: Included constantly.
    251 - Pre-cycle of the "Comfort" mode, min - from 0 to 30.
    252 - Launch of the DHW start (protection against hydraulic impact), C - from 5 to 200.
    253 - Shutdown logic DHW - 0: Protection against scale (62 or 65 C). 1: Installation +4 C.
    254 - Delayed circulation and ventilation delay in GVS mode - 0: Delayed ventilation disconnection, 1: Ventilation delay: 3 min.
    255 - Start delay from after DHW, min - from 0 to 30.

    Protective devices - In case of violation of normal operation, two types of the reaction of the boiler ARIRISON CLASS 24 FF are possible: stop (reset when resetting the "Reset" button); Protective shutdown (Resetting with the Reset button is not possible, it is necessary to resolve the cause of the malfunction). If the violation of the normal operation is not accompanied by the disption of the device, the error messages of the third type (alert) are displayed. In the case of a stop or protective shutdown, the indicator displays the alternately appropriate error code and the inscription "ERR".

    Ariston Clas Boiler Error Codes

    Error codes are distributed in six functional subsystems. The first digit of the code indicates how the functional subsystem of the device includes the appropriate violation of the work: the primary contour; Contour of DHW; ECU; Data exchange with peripheral devices; Rosge and detection; Air supply and removal of combustion products, zones.

    101 - overheating.
    103 - Circulation or water availability: gradient TPD. 7 C / s 3 times.
    104 - Circulation or water availability: gradient TPD. More than 20 C / s or TEBR gradient. more than 20 c / s.
    105 - Circulation or water availability: 55 c / s 3 times.
    106 - circulation or water availability: + 10 C 3 times.
    107 - Circulation or water availability: + 30 C Reset.
    110 - The temperature sensor for feeding in the contour of CO (NTC 1) is a short circuit or chain rupture.
    112 - The temperature sensor for feeding in the contour of CO (NTC 2) is a short circuit or chain rupture.
    114 - Outdoor temperature sensor - short circuit.
    116 - Room sensor - chain break.
    1p1 - circulation or water availability: gradient TPD. More than 7 c / s.
    1p2 - circulation or water availability: TPD. - Tob. Over 55 C.
    1p3 - circulation or water availability: Tob. More tapping + 10 C.
    201 is a sensor for feeding in the circuit of DHW (NTCS) - short circuit or chain rupture.
    202 - The reduced temperature sensor in the accumulator is a short circuit or chain rupture.
    203 - Power sensor - short circuit or chain rupture.
    204 - Sensor in the helix collector - short circuit or chain rupture.
    205 - Sensor at the inlet of cold water (helix) - short circuit or chain break.
    206 - Sensor at the entrance in the DHW circuit (from the helium system) - short circuit.
    207 - overheating of the helicing pipeline.
    208 - Sensor of the reduced temperature of the helix pipeline (freezing protection).
    209 - overheating the drive.
    301 - ESPRESE display failure.
    302 - GP - GIU Malfunction.
    303 - internal error of the Clas System boiler.
    304 - more than five discharges for 15 minutes.
    305 - Internal ECU error.
    306 - ECU internal malfunction.
    307 - Internal ECU Board Error.
    401 - Error sharing between the modem and the tire.
    402 - MODEMA GPRS / GSM malfunction.
    403 - Modem SIM-Card Error.
    404 - Multiple sharing between the modem and the board.
    405 - Modem error.
    406 - Modem malfunction.
    407 - Indoor temperature sensor - short circuit or chain rupture.
    501 - no flame.
    502 - Flame was found with a gas valve closed.
    5p3 - Out of the flame in the process.
    601 - Sensor overheating of the combustion products (only in the devices with an open chamber).
    602 - Sensor overheating of the products of combustion products (only in the devices with an open chamber, VMC type.
    607 - Pressure relay worked before the start of the ignition sequence.
    6p1 - delay in the closure of pressure switch contacts.
    6p2 - opening the contacts of the pressure switch with a working burner.

    Ariston Clas Evo.

    Modifications of Gas boilers Ariston Clas Evo: 24 FF, 24 CF, 28 FF, 15 FF

    Boiler hydraulics unit

    The right hydraulic node is a modular node with built-in functional elements: Filter CO and DHW. All elements are attached on retainers. Pump block with deaerator valve. Brass fittings for installation. Filter crane.

    The left hydraulic node is a modular node for the supply of hot water in the heating circuit and DHW: safety valve with 0.3 MPa (3 bar). Automatic bypass. Brass fittings. Everything copper tubes Must with clamps.

    The three-way valve - the three-way valve serves to change the water distribution (in the contour of heating or the secondary heat exchanger). The valve control is carried out from the electronic control unit (ECU) through the relay contact. The valve consists of a composite material housing, and an electric drive (engine). When the device in standby mode, the valve is in the "Sanitary" position (DHW). The procedure for switching the 3-way valve. The boiler in standby mode, the valve is in the "Sanitary" position: when the heating is turned on: the start of the operating cycle in the heating mode is delayed by 7 s (the time required to switch the valve using an electric drive with "GVS" to "CO" ). When the team arrives at the DHW: the device immediately begins to work in the "DHW" mode.

    The valve in the "Heating" position (CO): When the command arrives at the DHW: the valve switches from "with" to "DHW", while the pump and the burner continue to work. After receipt of the command to the DHW: If the heating command is not removed, the pump and the burner are turned off by 7 s (the time required to switch the valve using the drive with "DHW" to "CO". Clace Clas Evo System starts working in "Heating" ". The 3-chassing valve is activated by an easily dismantled ELBI electric motor. Replacing the electric motor can be carried out without draining water from the boiler. It is enough to remove the lock and disable the power wire. The signal from the computer enters the engine according to what mode (CO + SEV or Only DHW) sets on the control panel. The valve has two end switch (right / left), with which the servomotor is shutdown when the required position is shown.

    The secondary heat exchanger is a secondary heat exchanger of the ARIRISON Clast Evo 24 FF attached to the hydraulic node with two screws. The holes for the screws are located on the housing of the heat exchanger asymmetrically, due to which it can only be installed in the correct position. Installation on the temperature of protection against scale - aims to reduce the formation of scale in the secondary heat exchanger. In the DHW mode, the burner is turned off and turned on depending on the readings of the NTC1 and NTCS temperature sensors.

    Pump block. Pump type: Models 24 and 28 kW. WILO MTSL 15/5 HE-2; Model 32 kW. Wilo MTSL 15 / 6.7-2 CLF12. The computer allows you to control the switching of the circulation pump from one rotation frequency, V2 (55 W), to another, V3 (80 W). In the DHW mode, the pump always works at the frequency of rotation V3 to provide the best heat exchange. In the heating mode, the pump can work on one of the two speeds. The value is determined by the difference in temperatures on the supply of water in the contour of heating and the reverse fitting (DT). Procedure: Tpod.-arr. T - 2 C is greater than V2; Tpod.-arr. T MORE V3, where T \u003d 20c (the value is set to parameter 239 ranging from 10 to 30 c).

    Switching both smaller and the larger speed is carried out with a delay of 5 minutes (unchanged value). Parameter 238 Copper Ariston Clast Evo allows you to prohibit the pump switching from one rotation frequency to another: 0: Fix. Rotator frequency. 2; 1: Fix. Rotator frequency. 3; 2: Adjustable. The stipulation protection system includes a circulation pump and a 3-run valve for 15 seconds every 21 hours from the last action. To control the frequency of rotation of the pump, the value of parameter 823 can be used or the voltage (alternation) between the contacts 5 and 6 of the CN10 block connector electronic control: 145 V: the highest frequency of rotation; 0 Q: The smallest speed of rotation;

    Pouring the heating contour manually - the order of fill the contour of the CO (empty) is given further: open the crane at the inlet of the tap cold water. Remove the Deaerator plug. To open the filling valve, using a magnetic key (fixed under the hydraulic node), install the fill valve to the valve position open, the contour of the CO contour begins.

    Semi-automatic feed contour feed - "Semi-automatic feeding" mode should be used only if you need to feed the primary circuit. Use to fill an empty system is prohibited. On the solenoid valve A variable voltage of 230 V (pins 1 and 2 connector CN12 ECU), resistance of 3.7 com. In the DHW mode, this mode does not work. Parameter 248 allows you to prohibit semi-automatic feed: 0: prohibited; 1: Allowed.

    If the pressure is less than 0.6 bar, the feeding mode is turned on, the icon is displayed on the CLAS EVO System boiler display; In this case, by pressing the button 13, the "Filling system" cycle is started:

    The three-way valve switches to the CO position;
    - if the pump was turned on, it turns off;
    - if the burner was turned on, it turns off;
    - after the first fill, pressure is monitored; With a negative result of monitoring, an error message is 1p5 (between B and A);
    - monitoring the constancy of pressure; With a negative result of the control, an error message is issued 6p1 (between C and B1);
    - To achieve the set pressure value, the second fill cycle is performed.

    Ariston Clas Evo boiler error codes (when filling)

    Error 102 - Pressure sensor is not connected or a short circuit occurs in it.
    Error 109 - pressure above the maximum (3 bar).
    Error 111 - pressure below the minimum (0.4 bar).
    Error 1p4 - pressure below displayed (0.6 bar).
    Error 1P5 - the first fill cycle is complete (the pressure in the boiler has not risen): Press the corresponding button and try fill it again.
    Error 1P6 - Pressure Constability Monitoring Gave a negative result: Press the corresponding button and try fill out again.
    Error 1p7 - more than 5 cycles of fill in 50 minutes, the fill button is blocked (for reset: disable and re-enable).
    Error 1p8 - more than 6 fill cycles in 7 days, the fill button is blocked (for reset: off-incl).

    Pressure sensor in the heating circuit - a proportional pressure sensor is designed to measure pressure in the primary circuit. The measured value is displayed on the display of the ARIRISON boiler class Evo 24 FF. Control is carried out by measuring voltage ( direct current) Between contacts 8 and 9 CN04 connector. Compliance of voltage and pressure values: 0 bar \u003d 0.3 V, 1.5 bar \u003d 2.5 V, 3 bar \u003d 4.8 V. If a voltage is 0 V (pressure sensor is not connected) or 5 V (the input is incorrectly connected and output), a protective shutdown is carried out 102.

    Bypass - Bypass in the boiler commutated automatically, in the adjustment this node does not need. In the case of pressure loss in the circuit of the CO due to the operations of the thermostat or zonal valves, due to the bypass, water consumption is ensured through the main heat exchanger of at least 350 l / h. In addition, the automatic bypass prevents the heat exchanger overheating, which can occur with insufficient water flow. In this case, the temperature adjustment in the boiler is carried out in the usual way, the burner is turned off upon reaching the setpoint. Bypass is located in the feed assembly and closed with a three-way safety valve.

    The primary heat exchanger is the primary heat exchanger of the ARISTON CLAS EVO 24 FF, 24 CF, 28 FF, 15 FF is made of copper with anti-corrosion silicone coating. It is designed to transfer heat combustion products in the primary circuit. There is an overheating sensor with an automatic reset, triggered at 102 ± 4 C. Model - Quantity Round / Overall dimensions: 24 CF - 82/260 x 180 mm, 28 CF - 89/300 x 180 mm, 24 FF - 91/260 x 180 MM, 28 FF - 91/260 x 180 mm, 32 FF - 105/300 x 180 mm.

    Expansion tank - With increasing water temperature, the expansion tank compensates for an increase in its volume. The tank consists of two compartments separated by a membrane from butadiene-styrene rubber. One compartment is filled with nitrogen, the second water comes from the primary contour. The nitrogen compartment can be compressed as the water volume increases with increasing temperature. The expansion tank is designed for a heating system with a water volume of about 175 liters. Specifications - Capacity - 8 liters. The largest operating temperature is 90 C. Nitrogen pressure - 0.1 MPa (1 bar). The greatest working pressure is 3.0 MPa (1 bar).

    DHW flow meter - In the DHW flowmeter, there is a turbine that rotates the flow of water in the DHW circuit, and the rotational speed meter, the signal from which the Clas EVO System boiler control is connected. There is also a cold water filter that prevents the flow meter contamination. In addition, there is a device for protection against hydraulic impact (with control from the ECU). To configure the parameter 252, allowing
    Set the response time from 0.5 to 20 s (default 0.5 s). The water flow rate in the DHW circuit indicates the 825 parameter. It can also be displayed on the indicator by pressing the Info button. To control, you can measure the voltage (DC) on the CN14 connector: 0 B \u003d no consumption; 5 V \u003d consumption is absent; From 2 to 3 V \u003d consumption is available. Water analysis is available: 100 l / h. Water analysis is absent: 80 l / h.

    ARISTON GENUS.

    Gas boilers Ariston Genot are designed to supply heat and are installed in residential buildings and rooms. Models of wall boilers Genus: 24 FF, 35 FF, 24 CF, 30 FF.

    Elements of FF models. Sealed combustion chamber - neck of the air supply of a two-channel gas plant, air pressure switch, a condensate supply at the inlet of air pressure switch, a coolant overheating sensor, a primary heat exchanger, a temperature sensor (with a negative temperature coefficient) of water in the contour of heating (NTC 1), burner and electrodes , Gas valve and
    Electroscapor ignition generator, DHW temperature sensor (NTCS). Safety valve 0.3 MPa (3 bar), pump, water temperature sensor on reverse fitting CO (NTC 2), stepless adjustment fan, sampler for analyzing combustion products, gas pipe nozzle for combustion products, Hall sensor.

    Elements of CF models Open combustion chamber - nozzle of the gas plant, combustion product temperature sensor, coolant overheating sensor, temperature sensor (with a negative temperature coefficient) of water on the supply of CO contour (NTC 1), burner and electrodes, gas valve and electric ignition generator, GVS temperature sensor ( NTCS), safety valve 0.3 MPa (3 bar), pump, water temperature sensor (with a negative temperature coefficient) on the reverse fitting CO (NTC 2), primary heat exchanger.

    Operation of the ARISTON GENUS boiler in heating mode - the heating team can come from: room thermostat 1, room thermostat 2, programmer timer, remote control Remocon and room temperature sensor. The display shows C, then the temperature is applied to the CO contour (measured by the NTC1 sensor). When the device in standby mode, the valve is in the "Sanitary" position (DHW). When the heating is turned on, the servomotor, overlapping the output of the secondary heat exchanger, is triggered (the shaft is extended), the pump input is connected to the heating contour. Running the circulation device is carried out with a delay of 7 seconds after the heating command so that the three-way valve can switch; After that, the circulation device sends water from the reverse fitting to the primary heat exchanger.

    Fan (models with a hermetic chamber) are turned on. After the pressure relay is triggered, the machine can go to the next step (the repeated test of the pressure switch is not carried out until another restart). If the relay does not work, after 20 minutes, the device performs a protective shutdown of 6p1, the fan continues to rotate until confirmation (model with a hermetic chamber). After the air pressure switch is triggered, the gas valve and the ignition generator turn on. Gas supply is carried out at the rate of 80% of the ignition power in soft mode; This value can be adjusted using the parameter 220. The presence of an ion current flame is monitored (using the control electrode). The 5P1 error indication indicates the absence of ignition.

    Boiler Ariston Genot makes an ignition attempt in soft mode (at 90% power). In case of failure to the indicator, a fault of 5P2 is displayed, the third ignition attempt is made at 100% ignition power in soft mode. If the third attempt is unsuccessful, the device has stopped. Protective delay 8 s. To control the temperature sensors are used in the contour and reverse fitting. Used values \u200b\u200bof DT sub. and the speed of the flow of temperature on the feed and reverse fitting. Pressure is measured using a pressure sensor. After the flame is detected in the apparatus, heat power can be regulated in accordance with the required heat output. Adjustment can be carried out throughout the range of thermal power values \u200b\u200b- from maximum (installed from the control panel - parameter 231) to the minimum (fixed; installed on the gas valve).

    The turning off temperature of the burner is adjustable as follows:

    1 minute after flame detection: T off. \u003d T set. + 8 C.
    - 2nd minute after flame detection: T off. \u003d T set. + 6 C.
    - Starting from the 3rd minute after the flame detection: T off. \u003d T set. + 4 C.

    Such an order allows you to prevent too quickly disconnecting the burner when the installation is reached by temperature. It is possible to set the shutter speed before reapplying from 0 to 7 minutes (by default 2 minutes, it is installed from the control panel - parameter 236). The pump can work on one of the two speeds. The value is determined by the difference in temperature on the supply of water in the contour of the CO and the reverse fitting. Overheating protection is carried out using a temperature sensor with automatic reset (102 ± 4C) on the supply of CO contour (even with a disabled burner). When the sensor contacts are blurred, the burner is protected, and after 5 s, if the contacts are still open, the blocking of the machine (not allowing the operator again), an error 101 is displayed on the display. From the receipt of the command to heating the signal "Limit temperature" (88 C, unchangeable value) is constantly coming from the water temperature sensor to feed in the heating circuit (NTC 1). If circulation in contour from violated, it is possible to automatically switch to the bypass (bandwidth of no more than 350 l / h).

    The order of the ARISTON GENUS boiler in DHW mode - water consumption in the DHW circuit is measured using a flow meter. Now the boiler works in Sanitary mode (DHW). The display displays the letter D and the temperature setting. When the device in standby mode, the valve is in the "Sanitary" position (DHW). If a hot water supply team arrives during the operation of the device in CO mode, the three-way valve switches to the Sanitary position (DHW). In this case, the circulation pump and the burner continue to work. The output of the secondary heat exchanger is connected to the inlet of the pump that feeds the water to the primary heat exchanger. The pump (rotation frequency 3) pumps water from the secondary outlet and sends to the primary heat exchanger. The fan is turned on at the maximum rotational frequency (model with a hermetic chamber). After the air pressure switch is triggered, a transition to the next step is possible.

    If the relay does not work, after 20 minutes, the device performs a protective shutdown (Error 6P1), the fan continues to rotate before confirmation (model with a hermetic chamber). In models with an open camera, instead, control from the overheating sensor (valid even during the operation of the device). If the combustion product overheating sensor is triggered, the unit performs stop 601. After the air pressure switch is triggered, the gas valve and the ignition generator turn on. The gas supply is carried out in accordance with the thermal power in soft ignition mode (installed from the control panel of the parameter 220). The presence of a flame in
    ion current (using the control electrode). Indication 5P1 indicates the absence of ignition. The Ariston Genus 24 CF / FF, 35 FF, 30 FF, is trying to ignite in soft mode (100% power).

    In case of failure to the indicator, a fault of 5P2 is displayed, the third ignition attempt is made at 100% ignition power in soft mode. If the third attempt is unsuccessful, the device stops with an error 501. Protective delay 8 s. To control the flow of water, the temperature sensors are used in the contour and the reverse fitting. Used values \u200b\u200bof T sub. and the speed of the flow of temperature on the feed and reverse fitting. Pressure is measured using a pressure sensor. The burner flame adjustment can be carried out throughout the range of thermal power values \u200b\u200b- from the maximum (installed on the gas valve) to the minimum (also installed on the gas valve). The burner is running until the installation is reached on the protection temperature from scale. This temperature measures the NTCS sensor in the DHW circuit. Overheating protection is carried out using a temperature sensor with automatic reset (102 ± 4 C) on the feed in the contour of heating (even when the burner is disabled). When the sensor contacts are blurred, the burner is protected, and after 5 s, if the contacts are still open, - blocking the device (not allowing the operator again), an error 101 is displayed on the display.

    Working modes

    Mode "Pediffle" - mode is used to properly analyze combustion and calibration products at maximum and minimal values. Press the RESET button and hold 5 s. If the boiler is in the "Winter" mode (Winter), the three-way valve is in the "CO" position, and the burner is even turned on without a heating. Apparatus in the "Summer" mode: in the absence of a command on the DHW, the device operates in CO mode; If there is a command on the DHW, the device operates in DHW mode. In the "Pedochil" mode, the temperature measurement (NTC 1 sensor) is as follows: Summer mode more than Rez.: 86 C; ON: 81 C; Mode "Winter" more than Rez.: 89 C; ON: 84 C. To exit the "Pedroid" mode, press the RESET button. If this is not done, after 10 minutes the device automatically comes out of this mode.

    Comfort mode - in this mode ARISTON GENUS 24 FF, 35 FF, 24 CF, 30 FF, 30 FF begins to serve hot water in the DHW circuit faster. To this end, in the primary circuit of the boiler supported heat. Click the COMFORT button (Comfort - Comfort). In the comfort mode, the display is displayed on the Comfort icon and the letter C, as well as the temperature measured by the NTC1 sensor. The device switches to Comfort mode for each team on the DHW and supports it for 30 minutes. To exit this mode, press the "C" button. Parameter 2 50 Allows you to adjust the "Comfort" mode as follows: 0: Disabled; 1: Enabled within 30 minutes after the command on the DHW; 2: Included constantly.

    "Freezing Protection" mode - the mode is valid only when the ON / OFF switch is in the ON position. The transition to this mode is carried out according to the indications of the temperature sensor on the supply in the contour of CO (NTC1). The temperature measured by the NTC1 sensor: from 3 to 8 C - the pump operates at speed III. The three-way valve switches alternately for 1 min to "CO" mode, for 1 min - to "DHW" mode. The display shows the letter F and the temperature value measured by the NTC1 sensor. Action time: While the temperature measured by the NTC1 sensor does not reach 9 C. The temperature measured by the NTC sensor 1: below 3 C - the burner is turned on at a minimum of power; The pump operates at speed III. The three-way valve is in the "CO" position. The Ariston Genus boiler display alternates the letter F, digit 2 and temperature measured by the NTC1 sensor. Action time: While the temperature measured by the NTC 1 sensor does not reach 30 C.

    If the temperature sensor appears in the contour from NTC 1 does not act (a short circuit has occurred or occurred), the transition to the "freezing protection" mode is performed according to the NTC 2 sensor readings on the reverse fitting, but in this case only the pump is running (the burner does not turn on) . The display shows not the designation of the freezing protection mode, and the NTC 1 sensor error code 110 with a short circuit or chain break. The device switches to freezing protection mode, even if the NTC 2 sensor does not act (a short circuit is open or occurred), but in this case only the pump works (the burner does not turn on). The display shows no measurement of the freezing protection mode, and the NTC 2 sensor error code 112 is a short circuit or chain rupture. The device goes to freezing protection mode, even if there has been a shutdown due to the unnecessary flame, error code 501, or blocking due to overheating, error code 101, but in this case only the pump works (the burner does not turn on), and on the display Displays no designation of the freezing protection mode, and the blocking error code. In case of disconnection
    Power supply, all settings are saved in the machine, and after restoring the power, it goes to that mode in which it worked before disconnection.

    Ariston Genus Boiler Combustion Products Reference System

    On the external part of the device there is a collector of combustion products, with two samplers to determine the temperature of combustion and air products at the inlet, O2, CO2 content, etc.

    Air pressure switch - to control the proper removal of combustion products in the device there is a pressure relay. 25 kW: Opera. \u003d 50 Pa (0.50 mbar); Zone \u003d 60 Pa (0.60 mbar); 30 kW: Opera. \u003d 74 Pa (0.74 mbar); Zone \u003d 89 Pa (0.89 mbar); 32 kW: Opera. \u003d 74 Pa (0.74 mbar); Zone \u003d 89 Pa (0.89 mbar); The first pressure value is removed at the outlet of the fan (Fitting "L" of the pressure relay). The second pressure value is removed in the combustion chamber ("H" fitting of the pressure relay). Both values \u200b\u200bare negative (below atmospheric), but the pressure relay controls the difference of these values \u200b\u200b(to measure this difference, you can connect a differential pressure gauge to the pressure selection fittings located at the top of the device). When the boiler is working, Ariston Genot Contacts Pressure Relay are closed. The device responds to opening contacts. 607: Pressure relay contacts are closed before the ignition sequence. 6p1: Pressure relay contacts are not closed, although the fan turned on.

    The fan with adjustable rotation frequency - the following fans are used: 24 kW: with engine 35 W; 28 kW: 45 W engine; 32 kW: with engine 60 W; To measure the frequency of fan speed, the Hall sensor is used. For the receipt of the command for heating, the ECU launches the fan with the maximum rotation frequency (up to 2800 min-1). After the pressure switch is triggered, the fan switches to the ignition speed (different for gVS modes and CO), which allows you to optimize the burner ignition. After the presence of a flame is registered with the control electrode, the frequency of the fan rotation can be controlled in accordance with the required thermal power.

    The fan speed is adjustable in accordance with the supply of gas through the gas valve to the side or decrease, respectively, its winding is given a greater or smaller current. To control the frequency of rotation on facial side Fan installed Hall sensor. If for 10 minutes, the fan speed becomes more than 100 min-1 below the minimum (1750 min-1) or if the connection is detected with the Hall sensor, the error signal 604 is displayed: the fan shutdown delay is delayed: 40 s at the maximum speed of rotation ; 2 min - at minimal. To control the frequency of rotation of the fan in Min-1, use the parameter 8 22 or measure the frequency of the signal between the pins 4 and 5 of the CN07 connector. Parameter 222 Allows you to prohibit the pump switching from one rotation frequency to another: 0: Adjustable; 1: Fixed.

    Ventilation delay - the fan works with a shutdown delay: 40 s at a frequency of 1900 min-1 (after shutdown 501 and 103); 20 s at the maximum speed of rotation (after stops caused by the absence of water circulation: 103, 104, 105, 106 and 107), 10 s per 1900 min-1 (after stops caused by the absence of water circulation: 1p1, 1p2 and 1p3); 5 s for 1900 min-1 (after each disconnection of the burner).

    Delayed fan shutdown after the heating command: Parameter 243 \u003d 0: 5 s per 1900 min-1 (every time after turning off the burner); Parameter 243 \u003d 1: 3 min per 1900 min-1 (every time after disconnecting the burner).

    Fan shutdown delay after the DHW command: Parameter 254 \u003d 0: TPD. less than 75 c \u003d turns off without delay; Tapping more than 75 c \u003d 3 min (minimum rotational speed); Parameter 254 \u003d 1: 3 min (constant time, minimum speed).

    Control of combustion products (ARISTON GENUS 24 CF boilers, an open combustion chamber) - an automatic discharge control sensor, installed in the combustion product pathway, receives a signal to the ECU than proper control is provided, provided that there is power on the computer. When the overheating sensor is triggered, the device shutdown is performed, error cipher 601 is displayed on the indicator. Cause of the trigger: The temperature in the combustion product path has exceeded the sensor's response installation, 75 ± 3 C. After 12 minutes, the sensor is automatically reset, since the temperature is automatically reset. . To immediately reset the sensor, you can turn off and re-enable the power of the ECU. Error messages when the overheating sensor is triggered - 601: the overheating sensor worked (protective shutdown). 601: Overheat sensor chain break (protective shutdown).

    The combustion product removal system (sealed chamber, FF models) - the device allows installation of both coaxial (60/100 mm) and two-channel (80/80 mm) of gas ducts (respectively, two options for attachment). Samplers for analyzing combustion products are built into the neck of the combustion product collector.

    Error codes Boilers Ariston

    Heating contour

    Error 101 - overheating of the primary heat exchanger. Worked / faults overheating thermostat or NTC sensor temperature above 102C. Check / hold the maximum gas valve pressure adjustment. Clear / replace the heating contour filter. Skip in the heat exchanger. Washing / replacement of the heat exchanger. Check for damage circulation pump.

    102 - short circuit or breaking in the electrocups of the pressure sensor of the coolant.

    103 - Insufficient circulation or no heat carrier: Growing T supply more than 7 c / s (when repeated three times). Check the pressure of the coolant in the heating circuit, or remove air from the ARIRISON boiler. Cleaning, or replacing the heating contour filter. Check for damage circulation pump.

    Error 104 - Insufficient circulation or no heat carrier: Height of feed temperature or refund more than 20 c / s. Check the pressure of the coolant in the heating circuit, or remove air from the ARISTON boiler. Cleaning, or replacing the filter heating circuit. Check for damage circulation pump.

    Error 105 - circulation or availability of water: Tubes - profile more than 55c (three times).

    106 - Circulation or Water Having: Television Away .. More T under. + 10C (when repeated 3 times).

    Error 107 - circulation or water availability: the temperature rates. More t under. + 30C.

    Error 108 - Low pressure in the heating circuit (appropriate). Check the pressure of the coolant in the heating circuit, or remove air from the boiler. Check the wiring to the pressure relay. Check, or replace the pressure relay. Check the heating circuit and tightness boiler. Cleaning, or replacing the filter heating circuit. Check for damage circulation pump.

    Error 109 - the test for "reliability" is not passed. The temperature of the return line during the launch of the ARIRISON boiler is larger than the temperature in the heating system for 5 C. Make sure the NTC 1 and NTC 2 sensors have contact with the heating nozzles. Check the pressure of the coolant in the heating circuit. Check the wiring to the pressure relay. Replace the pressure relay.

    Error 110 - Sensor in the heating line (NTC 1) open or short circuit. Check the NTC1 temperature sensor contacts. Replace the NTC 1 temperature sensor.

    111 - reduced pressure, or lack of coolant (p lange p min.) For boilers Ariston with a "semi-automatic feeding" function

    112 - Sensor in the return of heating (NTC2) open short circuit. Check the contacts of the NTC temperature sensor 2. Replace the NTC 2 temperature sensor.

    114 - short circuit or breakdown in email. Chains of the outdoor temperature sensor.

    116 - The safety thermostat of the low-temperature system of in-depth heating has enabled.

    Hot water circuit (DHW)

    201 is a short circuit or opening in the electrical circuit of the DHW temperature sensor (NTCS).
    202 - short circuit or opening in the electrical circuit of the lower temperature sensor of the boiler (solar heat supply system).
    203 - short circuit or cliff in the electric boiler temperature sensor circuit (for boilers with boiler).
    204 - short circuit or cliff in the electrical circuit of the solar collector temperature sensor.
    205 - Sensor at the input of the DHW (Sunny) - the circuit is open or a short circuit.
    207 - overheating in the heating circuit of the solar collector (system of solar heat supply).
    208 - Low temperature In the circuit of the solar collector (freezing protection).
    209 - overheating of sanitary water in a boiler

    Electronic Boiler Boilers Ariston

    301 - Display Board Error. There is no contact between the main board and the display board. Check the correctness of installing the EEPROM key on the main board. Check Contacts. If necessary, replace the display fee.
    302 - Communication error between the main board and the display board. There is no contact between the main board and the display board. Check Contacts. If necessary, replace the display fee.
    303 - Malfunction of the main board. Bad contact between the main board and control board. Check the maintenance of the main board.
    304 - over 15 minutes more than 5 reset operations are performed. Turn off and run the boiler with the on / off button.
    305,306,307 - an internal error of the eba.
    3p7 - programmed service.

    Errors - Razhigig and Flame Control

    501 - Error: No flame found at the moment of ignition. Gas is missing. No contact, or the ground is not used. The voltage between the neutral and the "earth" is more than 10 V alternating current. Fault of the ionization electrode. Check the electrocontact and the integrity of the chain from the ionization electrode to the main board. Check, or to adjust the power of smooth ignition. Check for a malfunction the main fee.

    502 - the flame is found at a gas valve closed. Check, or replace the ionization electrode. The moisture hit the ionization electrode. Dry and ensure the protection of the boiler from the moisture of water vapor. Check, or replace the gas valve. Check the power characteristics and the presence of the ground loop. Check for damage the main fee.

    5p1 - failed to ignite the burner from the first attempt. Check the ionization electrode and its emiece. Check the gas pressure in the smallest and most power. Check the adjustment of smooth ignition and (if required) add it. Check the supply air system for burning / removing combustion products.

    5p2 - the second ignition attempt passed unsuccessfully.

    Error 5p3 - failed to ignite the burner from the second attempt. Check the combustion product outlet system. Check the gas pressure in the smallest and most power.

    Air supply / Deleting smoke

    Error 601 - triggering the thrust sensor (only in models with an open chamber).
    602 - worked the thermostat for controlling smoke removal (only in boilers with an open combustion chamber Type VMC).
    604 - Fan operation at low speed (less than 1775 rpm - 100 rpm) or malfunction of the Hall sensor.
    Error 607 - Pneummatore is included before the start of the fan.
    Error 6P1 - Pneummatore's trigger delay.

    Temperature zones

    701 - short circuit, breaking in the electrical circuit of the temperature sensor of the feed line (zone 2).
    702 - KZ or opening in the electrical circuit of the temperature sensor of the reverse line (zone 2).
    703 - KZ or open the temperature sensor of the feed line (zone 3).
    704 - KZ or open the temperature sensor of the reverse line (zone 3).
    705 - short circuit or breakdown in the electrical circuit of the temperature sensor hydraulic.
    706 - overheating in the temperature zone 2.
    707 - overheating in the temperature zone 3.

    Gas boilers are made by different companies, which is accompanied by the supply to the equipment market requiring an individual approach to installation and operation. But I do not want to overpay for the challenge of a specialist for installation work, right? But how to connect an ariston gas boiler yourself, given the individual features of the acquired equipment?

    We will try to help you deal with this task - our publication considers the procedure for installing, connecting and setting up a gas boiler. Also provides the sequence of work when performing the first run of the equipment. The stated material is supplemented visual photos and video.

    Wall boilersPerhaps are the most common among domestic gas equipment - their most often potential buyers.

    So, the modern gas wall mounted boiler ARISTON NET model allows you to: run, stop and monitor the temperature background of heating and DHW. Moreover, all these actions can be performed from anywhere at any time through the use of a familiar smartphone or personal computer.

    Here is such intelligent gas equipment on the example of a household boiler Ariston Net prefer to establish potential buyers of the XXI century

    The system provides constant control of energy consumption, which is accompanied by substantial gas savings. Thanks to the special softwareThe owner of the equipment receives notifications in real-time faults.

    In addition, if you activate remote control, it is possible to solve most of the problems remotely. However, let's first consider how to properly install the gas boiler of the home appointment of the Ariston brand, as well as the features of its connection, settings and procedures during the first launch.

    Stage # 1 - Study of the manufacturer's requirements for mounting

    Judging by the requirements for the manufacturer of boilers Ariston, the installation of equipment is the prerogative of exclusively specialists.

    Hence the appropriate conclusion - independent installation And the first inclusion of the household gas boiler Ariston is theoretically impossible (more accurate). Moreover, the first launch of equipment is prohibited without a representative of the gas service.

    The manufacturer also reminds the future user regarding the quality of water with which the gas wall boiler will operate. Notes: if water quality ( chemical composition) does not match technical requirementsThe performance of gas equipment is not guaranteed by the manufacturer during the prescribed warranty period.

    Installing gas equipment according to the "B" scheme requires an organization in the work premises of effective ventilation and air intake.

    The premises, where in the composition of the air, the appearance of corrosive vapors is possible, it is allowed to apply only the installation according to the scheme "C" (the influx of outdoor air). Such requirements provide corrosive protection of gas boilers Ariston.

    The kits for the connection of the chimney / duct, as a rule, are absent in the list of equipment of the gas boiler Ariston. Accordingly, additional kits are ordered to a specific connection.

    This is what the system "pipe in a pipe", which is used as part of the design of gas boilers Ariston of some models

    Many gas boilers brand Ariston are made taking into account the supply of air and removal of gases by means of a coaxial system, the diameters of the pipes of which are 60 and 100 mm. Or a separate version with pipes under the diameters of 80 per 80 mm can be used. The selection of the gases and the air duct configuration is accompanied by accounting for additional aerodynamic resistance.

    Stage # 6 - Connecting equipment to the power grid

    To complete safety, the manufacturer requires a qualified specialist for connecting and checking all electrical compounds of an ariston gas boiler. The manufacturer removes the equipment warranty if a low-quality power supply network is used and.

    The grounding circuit for the gas boiler installed inside the private house is a mandatory event requested not only for brand ariston boilers, but also for any other similar equipment.

    The power supply system is calculated on the maximum power parameter of the gas boiler. Electrical conductors are used to connect the equipment, having a cross section of at least 0.75 mm 2. Right safe job Gas boiler provides reliable grounding.

    Power parameters must be brought in accordance with the 230V / 50 Hz network standards when observing the polarity and the availability of the grounding conductor. The grounding conductor is required to apply greater lengths in relation to the phase conductor and neutral. Connecting wired - strictly constant, without using sockets and forks, made through.

    First start and setting up the boiler

    When S. assembly work And the connection is completed, you can proceed to setting up and testing the equipment.

    Performing the first launch

    Initial action accompanying the first launch of the Ariston gas boiler, is water. It must be installed air valves Radiators in the working (open) state.

    The same actions aimed at the release of air from the system are applied to circulating pump boiler. As the contour of water is filling, air output from the system, reaching the water pressure on the pressure gauge 1 - 1.5 atmosphere, the tap on the feed line is closed.

    The first launch of the gas boiler usually accompanize preparatory operations related to the filling of the water system, air incision, check the tightness of gas lines

    At the next stage of gas boiler commissioning, actions associated with gas supply are performed.

    The procedure for approximately the following:

    • open doors and windows of the work room;
    • eliminate the presence of open fire sources;
    • perform checking the burner scheme and regulation system for tightness.

    Testing the adjustment node and tightness burner is performed by the short-term opening (no more than 10 minutes) of the main shut-off valve of the gas line. In this case, the electromagnetic valve and the manual damper of the boiler are installed in the closed position. With this position of the system, the gas flow counter must show a zero result (no leakage).

    Stooking manipulations with control panel

    Contemporary gas heating equipment is equipped with a control panel, where the user can specify the desired parameters of the aggregate. Next, consider in more detail how to set up a household gas boiler brand Ariston.

    Management during the operation of the boiler, as well as control in the first start-up mode with the necessary settings, is carried out through the user control panel Ariston

    Actually, the user's actions on the control panel are obvious here:

    1. Enable the device activating the on / off button.
    2. Mark the operating mode parameters on the display.
    3. Mark on the display of the service mode.

    Next, the gas parameters are checked, for which the front panel is dismantled, the control panel plate is lowered and test manipulations are performed with the connection of the measuring pressure gauge to the pressure of the pressure selection.

    These operations - the prerogative of gas services specialists. Independent execution is not recommended, as it is necessary to clearly know the functionality of the equipment.

    Layout of the keyboard control ariston: 1 - information screen; 2 - Regulation of the temperature of the DHW; 3 - mode selection key (MODE); 4 - the "Comfort" function; 5 - on / off key; 6 - "Auto" mode; 7 - RESET reset key; 8 - Regulation of the temperature of the heating circuit

    Then the boiler starts in test mode through the system function "Pedochil". To enter the test mode, you should activate the reset button (RESET) and hold down at least 5 seconds. The output of the test mode is performed by re-activating the reset key.

    Testing Maximum / Minimum Power

    This type of test also provides for controlling pressure on specialized equipment points, followed by measurement of parameters on a pressure gauge. It is necessary to disconnect the combustion tube of the combustion chamber. Again, the "carbus" mode is used, activated through the control panel.

    Similarly, the boiler is tested to the minimum power level. True, the modulator's adjusting screw is additionally used, if required to adjust the value of the minimum boiler operating pressure. On this occasion, the video is placed below, where the modulator for some reason is called the engine.

    Running equipment commissioning

    The process of launching the device provides for the following user's running:

    1. Activate the ON / OFF button (ON / OFF).
    2. Select standby mode.
    3. Hold down the "Mode" button (MODE) 3-10 seconds.
    4. Wait for air removal cycle (about 7 minutes).
    5. Open linear gas crane.
    6. Enable DHW operation mode with Mode button.

    If all actions were performed by a master specialized Firm, then it checks the compliance of gas pressure during the operation of the unit and constitutes the corresponding act.

    

    Wall-mounted gas boilers from the series of modern equipment of the brand Ariston - a rather complicated technique, even if domestic use. Hence the logical output on the installation and launch of the gas boiler Ariston - the initial start of the system should be entrusted to specialists. Expenses, of course, are inevitable, but on the other hand, it is guaranteed proper work Gas system.

    Engaged in installing and configuring a gas boiler Brand Ariston independently or entrusted this work to specialists? Share your experience with other visitors to our site in the Comment Block - add a photo of your boiler, tell us about the difficult moments that you encountered in the process of owning equipment.